PVC lab: instrument list with estimates, and cost it
quality-automation.md: the day-one per-lot tier becomes a table with an instrument class and a rough price per check (moisture analyzer, strip oven, density balance, spectrophotometer, gloss, sieves, muffle furnace, stereo microscope), plus what was missing: a lab plaque press or two-roll mill so speck, color and DSC tests do not tie up a production press; sample conditioning as part of the method at 60 to 90 % ambient humidity; magnets for metal in lots and regrind. Day-one tier ~USD 55k to 150k (estimate); Karl Fischer and the ISO 182 Thermomat as options. Mature tier priced (~120k to 240k), handheld XRF as an option, and partner labs (Payap pharmacy, CMU science) to defer it. total-investment.md: the day-one tier goes into "Added scope, not yet in the roll-up" (55k to 150k USD, 1.8M to 5.0M THB); added total now ~290k to 690k USD, about 7 to 9 % on the subtotal. Headline total unchanged.
This commit is contained in:
1 parent
c56d403da0
commit
9b26cfbf7c
2 files changed
+64
-29
No files matched your search
@@ -45,7 +45,8 @@ software lines, and the contingency on top).
|
||||
| Maintenance workshop and machine bay fit-out | 30k – 76k | 1.0M – 2.5M | estimate, same |
|
||||
| Visitor corridor and accessible entrance | 67k – 148k | 2.2M – 4.9M | estimate, same |
|
||||
| Artist platform, public side (calculator, campaigns, payments) | 40k – 90k | 1.3M – 3.0M | estimate, [artist platform](../artist-platform.md) |
|
||||
| **Added so far** | **~235k – 540k** | **~7.7M – 17.9M** | about 6 to 7% on the full-vision subtotal |
|
||||
| PVC material lab, day-one tier (incl. plaque press and sample conditioning) | 55k – 150k | 1.8M – 5.0M | estimate, [quality automation](../quality-automation.md); not costed in the metrology block above. The mature tier (torque rheometer, DSC, FTIR, ~120k – 240k) is deferred, with partner labs in between |
|
||||
| **Added so far** | **~290k – 690k** | **~9.5M – 22.9M** | about 7 to 9% on the full-vision subtotal |
|
||||
|
||||
## Phased entry
|
||||
|
||||
@@ -55,7 +56,8 @@ A credible launch phase is far smaller, roughly **1.7M to 2.9M USD
|
||||
- Newbilt Single system (not Duplex yet)
|
||||
- Bridge stampers from Stamper Discs, so no galvanics line at launch
|
||||
- Basic QC (microscope, benchtop PVC lab, sampled listening), full
|
||||
metrology deferred
|
||||
metrology deferred; the PVC lab's day-one tier is the added-scope row
|
||||
above
|
||||
- Leased building instead of purchase, modest first solar array
|
||||
- Galvanics, automated presses, full metrology, and the biomass boiler
|
||||
follow as revenue-funded or second-round expansions
|
||||
|
||||
+60
-27
@@ -205,37 +205,69 @@ the lot ID follows every record pressed from it:
|
||||
|
||||
### The PVC lab, in tiers
|
||||
|
||||
Prices are rough list-price ranges per instrument class (estimates, not
|
||||
quotes; ask Thai distributors for local pricing and service).
|
||||
|
||||
**Per lot, in-house from day one** (benchtop instruments, all with data
|
||||
export for the traceability gate):
|
||||
|
||||
- Moisture content: halogen moisture analyzer or Karl Fischer titration;
|
||||
minutes per sample, and the most common cause of noisy surfaces
|
||||
- Heat stability: oven strips at pressing-relevant temperatures watching
|
||||
discoloration over time; the formal methods are ISO 182 (Congo red /
|
||||
conductivity), tracking HCl evolution
|
||||
- Density: checked against the compound spec; feeds record weight
|
||||
consistency
|
||||
- Color: spectrophotometer L\*a\*b\* against the reference, plus gloss for
|
||||
black compound
|
||||
- Granulate physicals: sieve analysis for particle size distribution, bulk
|
||||
density, dust/fines content
|
||||
- Ash content: muffle furnace burn-off as a filler-loading drift check
|
||||
- Pressed-plaque inspection for specks, gels, and contamination (shareable
|
||||
with the optical inspection investment)
|
||||
| Check | Instrument | Estimate, USD |
|
||||
|---|---|---|
|
||||
| Moisture, minutes per sample; the most common cause of noisy surfaces | Halogen moisture analyzer (Mettler HC / Sartorius MA class) | 3k to 8k |
|
||||
| Heat stability: oven strips at pressing-relevant temperatures, watching discoloration over time | Lab oven with timed strip racks | 3k to 8k |
|
||||
| Density against the compound spec; feeds record weight consistency | Analytical balance with density kit | 4k to 8k |
|
||||
| Color L\*a\*b\* against the reference lot | Spectrophotometer | 10k to 30k |
|
||||
| Gloss on black compound | Gloss meter | 2k to 5k |
|
||||
| Granulate physicals: particle size distribution, bulk density, dust and fines | Sieve shaker with sieve stack, bulk density cup | 3k to 8k |
|
||||
| Ash content as a filler-loading drift check | Muffle furnace | 3k to 8k |
|
||||
| Specks, gels and contamination on pressed plaques | Stereo microscope and light table (the method is shareable with the optical inspection investment) | 3k to 8k |
|
||||
| Test plaques for the speck count, color and DSC, without tying up a production press | Lab hot plaque press or small two-roll mill | 20k to 60k |
|
||||
| Sample conditioning (below) | Drying oven, desiccators, sealed retained-sample storage | 2k to 5k |
|
||||
| Metal contamination in lots and regrind | Grate or bar magnets at the hopper and regrind intake | under 2k |
|
||||
| **Day-one tier** | | **~55k to 150k** |
|
||||
|
||||
**In-house as the lab matures** (the PVC-specific workhorses):
|
||||
Two optional upgrades to the day-one tier: Karl Fischer titration for low
|
||||
moisture levels and supplier disputes (10k to 20k), and the formal heat
|
||||
stability method, ISO 182 Congo red / conductivity tracking of HCl
|
||||
evolution (Metrohm PVC Thermomat class, 20k to 35k).
|
||||
|
||||
- Torque rheometry (Brabender class): fusion/gelation time and torque,
|
||||
the standard predictor of how a PVC compound behaves in the extruder;
|
||||
plain melt-flow index is less informative for PVC than for other
|
||||
thermoplastics because the material is shear- and heat-sensitive
|
||||
- DSC: glass transition, additive signatures, and the record-relevant
|
||||
application of measuring the degree of gelation of a pressed record,
|
||||
which correlates with surface noise and durability, turning DSC into a
|
||||
process-tuning tool as well as an incoming check
|
||||
- FTIR: identity fingerprint; record compound is classically a vinyl
|
||||
chloride/vinyl acetate copolymer rather than pure PVC, and FTIR verifies
|
||||
the copolymer and catches unannounced formulation changes
|
||||
**Sample conditioning is part of the method, not an extra.** At 60 to 90 %
|
||||
ambient humidity granulate picks up moisture between the warehouse and the
|
||||
balance, so a moisture result is only comparable if the sample was taken
|
||||
sealed, conditioned the same way every time and tested within a fixed
|
||||
window. The lab sits in the conditioned QC zone ([scale](scale.md)) at the
|
||||
HVAC's controlled humidity, and the retained sample of every lot is stored
|
||||
sealed.
|
||||
|
||||
The plaque press makes the inspection plaques; the **release test
|
||||
pressing** of a new lot still runs on a production press, because that is
|
||||
the real test.
|
||||
|
||||
**In-house as the lab matures** (the PVC-specific workhorses, ~USD 120k to
|
||||
240k together):
|
||||
|
||||
- Torque rheometry (Brabender class, ~60k to 120k): fusion/gelation time
|
||||
and torque, the standard predictor of how a PVC compound behaves in the
|
||||
extruder; plain melt-flow index is less informative for PVC than for
|
||||
other thermoplastics because the material is shear- and heat-sensitive
|
||||
- DSC (~40k to 80k): glass transition, additive signatures, and the
|
||||
record-relevant application of measuring the degree of gelation of a
|
||||
pressed record, which correlates with surface noise and durability,
|
||||
turning DSC into a process-tuning tool as well as an incoming check
|
||||
- FTIR with ATR (~20k to 40k): identity fingerprint; record compound is
|
||||
classically a vinyl chloride/vinyl acetate copolymer rather than pure
|
||||
PVC, and FTIR verifies the copolymer and catches unannounced formulation
|
||||
changes and foreign polymers in the regrind
|
||||
- Option: handheld XRF (~25k to 40k) brings stabilizer and heavy-metal
|
||||
screening in-house for every lot instead of per supplier, worth it while
|
||||
Thai and regional compounders are being qualified
|
||||
|
||||
**Partner labs before buying the mature tier.** Pharmacy and science
|
||||
faculties routinely run FTIR, DSC and Karl Fischer; Payap University's
|
||||
Faculty of Pharmacy ([Payap partnership](payap-partnership.md)) and Chiang
|
||||
Mai University's science faculties are the obvious places to ask
|
||||
(unconfirmed which instruments they hold). Contract testing there defers
|
||||
most of the mature tier until lot volume justifies owning it.
|
||||
|
||||
**External lab, per supplier qualification** (not per lot):
|
||||
|
||||
@@ -252,7 +284,8 @@ The tiers define the protocol: the per-lot gate runs moisture, heat
|
||||
stability, color, density, and granulate physicals plus the release test
|
||||
pressing; a new supplier additionally gets the full external panel and
|
||||
pressing trials. This is the working method for qualifying Thai and
|
||||
regional compounds against the European references.
|
||||
regional compounds against the European references. The day-one tier is
|
||||
costed in [total investment](finance/total-investment.md) as added scope.
|
||||
|
||||