lampbench station / export / label / tm30 / calibrate replace the Python lamp_station.py, lamp_export.py, label_printer.py, tm30.py and calibration.py that lived in HPCS6500-py. The driver is a submodule (HPCS6500/, like mppt-testbench). Workspace crates: tm30 (TM-30-18 port of colour-science 0.4.7), brother-ql (raster protocol, byte-identical to brother_ql) and lamp-label (QR + ID labels for the QL-820NWB). Bundles are byte-identical to lamp_export.py's (golden tests); the station runs end to end in a test against the simulated instrument.
85 lines
2.1 KiB
JSON
85 lines
2.1 KiB
JSON
{
|
|
"name": "L0007",
|
|
"type": "halogen",
|
|
"dimmable": true,
|
|
"manufacturer": "",
|
|
"model": "",
|
|
"notes": "",
|
|
"instrument": "HPCS6500",
|
|
"measured_at": "2026-07-09T16:22:57+07:00",
|
|
"instrument_date": "2026-02-04",
|
|
"instrument_time": "16:29:39",
|
|
"readings_averaged": 1,
|
|
"tm30": {
|
|
"Rf": 82.8,
|
|
"Rg": 102.6
|
|
},
|
|
"cri": {
|
|
"Ra": 83.03077697753906,
|
|
"R1": 82.11673736572266,
|
|
"R2": 93.9566421508789,
|
|
"R3": 93.32406616210938,
|
|
"R4": 76.64042663574219,
|
|
"R5": 81.5961685180664,
|
|
"R6": 89.55091094970703,
|
|
"R7": 83.03118896484375,
|
|
"R8": 64.03005981445312,
|
|
"R9": 4.829061031341553,
|
|
"R10": 84.0609130859375,
|
|
"R11": 76.2067642211914,
|
|
"R12": 60.158180236816406,
|
|
"R13": 86.46263885498047,
|
|
"R14": 96.80621337890625,
|
|
"R15": 75.96227264404297
|
|
},
|
|
"supply": {
|
|
"ac_voltage": 230.0,
|
|
"ac_frequency": 50.0,
|
|
"dc_voltage": 24.0,
|
|
"dc_current": 5.0,
|
|
"mode": "AC"
|
|
},
|
|
"photometric": {
|
|
"Phi_lm": 479.5904235839844,
|
|
"eta_lm_W": 57.03839111328125,
|
|
"CCT_K": 5661.3740234375,
|
|
"Duv": 0.005495334509760141,
|
|
"SDCM": 4.661009311676025,
|
|
"TLCI": 67.88436889648438
|
|
},
|
|
"chromaticity": {
|
|
"x": 0.3286939859390259,
|
|
"y": 0.34864285588264465,
|
|
"u": 0.20145727694034576,
|
|
"v": 0.32052600383758545,
|
|
"u_prime": 0.20145727694034576,
|
|
"v_prime": 0.4807890057563782,
|
|
"CIE_X": 662.0042114257812,
|
|
"CIE_Y": 702.18212890625,
|
|
"CIE_Z": 649.8577880859375
|
|
},
|
|
"radiometric": {
|
|
"Phi_e_mW": 1492.0255126953125,
|
|
"Phi_euv_mW": 0.0,
|
|
"Phi_eb_mW": 470.2662658691406,
|
|
"Phi_ey_mW": 679.6720581054688,
|
|
"Phi_er_mW": 330.6041564941406,
|
|
"Phi_efr_mW": 11.205649375915527,
|
|
"Phi_eir_mW": 0.0,
|
|
"Phi_e_total": 1491.7479248046875
|
|
},
|
|
"electrical": {
|
|
"Voltage_V": 230.289794921875,
|
|
"Current_A": 0.06533221900463104,
|
|
"Power_W": 8.404895782470703,
|
|
"Freq_Hz": 50.02182388305664,
|
|
"PF": 0.5585951805114746,
|
|
"UThd": 0.8112547993659973,
|
|
"AThd": 109.011474609375
|
|
},
|
|
"sensor": {
|
|
"PeakSignal": 53165.0,
|
|
"DarkSignal": 2310.0,
|
|
"Compensate": 2834.0
|
|
}
|
|
} |