Document that via capping is deliberately not modeled, with error bound
Layer-to-layer the cap (>=15 um plating per fab spec) is parallel to the annular-ring contact, so it cannot change the DC path. In-plane the model treats every via mouth as solid layer-thickness copper; the error is bounded by the dilute-hole correction (~ +2x mouth-area-fraction locally), partially offset by the unmodeled annular-ring copper, and typically well under a few percent of total R. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -21,10 +21,12 @@ COPPER_THICKNESS_UM: float | None = None # None -> stackup, fallback 35.0 with
|
||||
FALLBACK_THICKNESS_UM = 35.0
|
||||
TEST_CURRENT_A = 1.0 # default injected current (dialog/CLI-selectable)
|
||||
VIA_PLATING_UM = 18.0 # barrel plating thickness (always plated).
|
||||
# Capped vs uncapped vias do not change the
|
||||
# layer-to-layer DC path: the >=5um cap sits
|
||||
# over the hole mouth in parallel with the
|
||||
# annular-ring contact, not in series.
|
||||
# Via capping is NOT modeled: layer-to-layer
|
||||
# the cap (>=15um per fab spec, thinner than
|
||||
# the foil) is parallel to the annular-ring
|
||||
# contact, not in series; in-plane every via
|
||||
# mouth is treated as solid layer-thickness
|
||||
# copper (error bound: see README).
|
||||
INCLUDE_TH_PADS = True # plated through-hole pads stitch layers too
|
||||
SKIN_SIDES = 1 # skin-effect field config: 1 = plane facing a
|
||||
# return plane (conservative), 2 = isolated foil
|
||||
|
||||
Reference in New Issue