Files
comparison-data/README.md
T
grabowski cfbeae2809 Import measurement data from buildfor_life_web
Lamp SPD/TM-30/metrics for four EANs and solar charge controller
efficiency sweeps, moved out of the web repo so measurement data
lives in its own history.
2026-07-09 11:11:52 +07:00

36 lines
1.8 KiB
Markdown

# comparison-data
Raw measurement data behind [buildfor.life/comparisons](https://buildfor.life/comparisons).
This repo is consumed by [buildfor_life_web](https://git.b4l.co.th/B4L/buildfor_life_web)
as a git submodule at `apps/web/comparison-data`. At build time the site copies it to
`/data/comparisons/`, where every file is both chart input and a raw download. Directory
names are the keys the site's device pages reference in their `csv:` front matter, so
renaming a directory here requires updating the matching page in the web repo.
## Layout
```
lamps/<EAN>/spd.csv SPD 380-1050 nm: wavelength_nm,value
lamps/<EAN>/tm30.csv ANSI/IES TM-30-18 per-hue-bin data (16 bins): Rcs, Rhs, Rf_h, ...
lamps/<EAN>/metrics.json Summary: TM-30 Rf/Rg, CRI Ra + R1-R15, CCT, flux, instrument metadata
solar-charge-controllers/<device>.csv Efficiency sweep: set/measured Vin, Iin, Pin, Vout,
Iout, Pout, eff_pct, heatsink and board temperature
```
Lamps are identified by their EAN barcode so results stay unambiguous across brands and
packaging variants. EANs starting with 2 are retailer-internal barcodes that cannot be
resolved publicly.
## Provenance
- Lamps: HPCS-6500 integrating sphere, 230 V / 50 Hz, five consecutive readings averaged
after stabilization. Instrument driver and TM-30 tooling:
[HPCS6500-py](https://git.b4l.co.th/B4L/HPCS6500-py). Procedure:
[lamp test procedure](https://buildfor.life/docs/tooling/lamp-test-procedure/).
- Solar charge controllers: automated MPPT testbench sweeps. Procedure:
see the linked test procedure on the comparison page.
Data is published as measured; files are never edited after the fact. Corrections happen
by re-measuring and replacing the whole device directory in one commit.