grabowski
|
808e3e34b8
|
Add quality automation spec: stamper metrology and layered record QC
- Keyence-class instrument stack for father/mother/stamper analysis
(VK-X confocal sampled zones, VR-6000 wide-area, XRF thickness) with
genealogy integration via middleware
- Three-layer pressed-record QC: 100% inline optical inspection,
per-cycle press telemetry, sampled automated audio comparison
- Honest limits documented: no turnkey products exist for the optical
and audio layers; 100% audio QC impossible at press speed
|
2026-07-17 13:56:45 +07:00 |
|
grabowski
|
0b79c4fb73
|
Add whole-factory HVAC requirement and process traceability spec
- facility-security.md: continuous temperature/humidity/PM control, zoned
filtration, burning-season PM2.5 design point, HVAC in PV/battery sizing
- traceability.md: end-to-end per-order customer traceability, batch
genealogy, log-at-source principles, machine data access as a
procurement requirement
|
2026-07-17 13:05:46 +07:00 |
|