Digital factory plan: build on the existing cnx-network clan
Rewrite docs/digital-factory.md against the fleet that already exists at git.b4l.co.th/B4L/cnx-network-clan instead of a plant-only clan: - The plant is one more site: gw-lpn-1 from the cnx.router module, plant machines in the same inventory, reached over the existing ZeroTier mesh (no VPS, no moon, no port forwards). - Fleet pieces reused as-is: control for host metrics, journals and host alerts; ns1/ns2 for the gateway wildcard cert; web01 as the public proxy for the customer portal; clan borgbackup with a plant server. - Process time series move from TimescaleDB to a plant-local VictoriaMetrics (same modules and rules as control); PostgreSQL keeps everything with identity. Object storage dropped for ZFS datasets. - VLAN table on the fleet addressing convention (siteId 3 assumed, ids above 40); OT segments as dual-homed islands behind the collectors; stations reach the app only through the gateway Caddy proxy. - New section listing every file that changes in the clan repo, the modules/vinyl/* to write, and three router-module extensions (NTP serving, static VLANs, second WAN). - Gaps the plant closes for the fleet: Alertmanager delivery, off-site backup destination, TSDB backup. - Repository layout decided: infra in cnx-network-clan, app in cnx-factory as a flake input, this repo stays documents. README bullet updated to match.
This commit is contained in:
1 parent
0fb60bcbb5
commit
ffcce42a51
2 files changed
+413
-276
No files matched your search
@@ -88,11 +88,12 @@ The detail lives in dedicated documents:
|
|||||||
shipment, and the requirements this sets for the factory software
|
shipment, and the requirements this sets for the factory software
|
||||||
- [Digital factory systems plan](docs/digital-factory.md): every system
|
- [Digital factory systems plan](docs/digital-factory.md): every system
|
||||||
that has to exist for environment, machine, QC and genealogy data to land
|
that has to exist for environment, machine, QC and genealogy data to land
|
||||||
in one database keyed to one record identity: the NixOS machine fleet
|
in one database keyed to one record identity: the plant as one more site
|
||||||
managed as one Clan, networks and VLAN zoning, Telegraf/MQTT acquisition
|
in B4L's existing NixOS fleet (the cnx-network clan: mesh, DNS, fleet
|
||||||
source by source, QC instrument integration, the factory application,
|
monitoring, site gateway module, public proxy), what changes in that
|
||||||
alerting, backup, security, the data clauses for every RFQ, build order
|
repo, VLAN zoning, Telegraf/MQTT acquisition source by source, QC
|
||||||
and rough cost
|
instrument integration, the factory application, alerting, backup,
|
||||||
|
security, the data clauses for every RFQ, build order and rough cost
|
||||||
- [Quality automation](docs/quality-automation.md): stamper metrology
|
- [Quality automation](docs/quality-automation.md): stamper metrology
|
||||||
(Keyence-class confocal, profiler, XRF), layered pressed-record QC (100%
|
(Keyence-class confocal, profiler, XRF), layered pressed-record QC (100%
|
||||||
optical inspection, per-cycle press telemetry, sampled automated audio
|
optical inspection, per-cycle press telemetry, sampled automated audio
|
||||||
|
|||||||
+407
-271
@@ -9,44 +9,84 @@ genealogy all land in one place, keyed to one record identity, and can be
|
|||||||
shown to a customer. It is a planning position as of September 2026; every
|
shown to a customer. It is a planning position as of September 2026; every
|
||||||
cost figure is an estimate until a quote replaces it.
|
cost figure is an estimate until a quote replaces it.
|
||||||
|
|
||||||
**Standing decision: every service runs on NixOS, and the whole fleet is
|
**Standing decision: every service runs on NixOS, and the plant is one more
|
||||||
declared and deployed as one [Clan](https://clan.lol).** Servers, edge
|
site in the existing B4L fleet, the
|
||||||
collectors, station kiosks, the router and the off-site VPS are all NixOS
|
[cnx-network clan](https://git.b4l.co.th/B4L/cnx-network-clan).** That
|
||||||
machines in a single inventory. Vendor instrument PCs (Keyence, vision
|
clan already runs the ZeroTier mesh, authoritative DNS, mail, fleet
|
||||||
controllers, PLC HMIs) are appliances, not servers: they export into the
|
monitoring, backups, a public reverse proxy and the first site gateway, all
|
||||||
NixOS estate and never host a service of ours.
|
declared in one repository and deployed with the clan CLI. The plant adds
|
||||||
|
a gateway, a core server, a backup server, edge collectors and station
|
||||||
|
kiosks to that inventory and reuses everything the fleet already provides.
|
||||||
|
Nothing is built twice. Vendor instrument PCs (Keyence, vision controllers,
|
||||||
|
PLC HMIs) are appliances, not servers: they export into the NixOS estate
|
||||||
|
and never host a service of ours.
|
||||||
|
|
||||||
|
## What the fleet already provides
|
||||||
|
|
||||||
|
Read the clan's own runbook (`docs/` in the repo, served on `control`) for
|
||||||
|
detail; this is what the plant plan leans on.
|
||||||
|
|
||||||
|
| Fleet piece | Where | What the plant gets from it |
|
||||||
|
|---|---|---|
|
||||||
|
| Clan repo, clan-core 26.05, sops vars gated by YubiKey, `admins` group applied to every machine automatically | git.b4l.co.th/B4L/cnx-network-clan | one inventory, one deploy path (`clan machines install` / `update`), secrets minted with `clan vars generate` |
|
||||||
|
| ZeroTier mesh, controller on `control`, IPv6 ULA `/88`, `modules/mesh-hosts.nix` reads every peer's address from vars | `control` | admin SSH, deploys and scrapes for plant machines behind PPPoE NAT, exactly as `gw-cnx-1` is reached today; no port forwards, no VPS needed |
|
||||||
|
| `modules/router/`: `cnx.router.*` on Topton 1U boxes: PPPoE WAN, VLAN-filtering bridge, nftables with no inter-VLAN traffic, Kea, Blocky, CrowdSec, Omada, iperf3, hourly speed test, Caddy internal proxy with a real wildcard `*.<site><n>.cnx.network` via DNS-01 | site gateways | the plant router is a copy of `machines/gw-cnx-1/` with its own VLANs; the internal proxy gives every station a browser-trusted `https://factory.<site>1.cnx.network` |
|
||||||
|
| Addressing convention `10.<siteId>.<vlanId>.0/24`, VLAN ids 10 mgmt and 20 lan mandatory, 30 guest, 40 iot reserved | fleet-wide | the plant takes the next free `siteId` and adds its own VLANs above 40 |
|
||||||
|
| VictoriaMetrics (180 d), VictoriaLogs (30 d), vmalert, Grafana, blackbox probes | `control` | node_exporter on every plant machine scraped over the mesh, journald shipped to VictoriaLogs, host alerts from the existing rules; process data stays on site (below) |
|
||||||
|
| Knot DNS (`cnx.network`, `buildfor.life`, `cnx.email`) with per-consumer TSIG keys for ACME | `ns1`, `ns2` | the plant's public names and the gateway's wildcard cert; a brand domain for the customer portal is one zone file away |
|
||||||
|
| `web01`: public Caddy with `*.cnx.network`, backends dialed over the mesh | Hetzner | the customer portal is one `virtualHosts` entry pointing at the plant core's mesh address, the same way `grafana.cnx.network` works now |
|
||||||
|
| clan `borgbackup` service, `control` as server, repokey encryption, backups over the mesh | `control` | the pattern; the plant needs its own server because plant data is far larger than the DNSSEC keystore |
|
||||||
|
| chrony everywhere, fixed-offset time zones (`Etc/GMT-7` for Thailand) | fleet baseline | plant machines inherit; edge collectors additionally serve NTP to the PLCs |
|
||||||
|
| mdbook runbook in `docs/src/`, built and served on `control` | `control` | the plant's operational runbook goes there as a chapter; this document stays the planning source |
|
||||||
|
|
||||||
|
Known gaps in the fleet that the plant needs closed (all on the clan's own
|
||||||
|
TODO list or small extensions to existing modules):
|
||||||
|
|
||||||
|
- **Alert delivery**: vmalert currently uses `notifier.blackhole`. A boiler
|
||||||
|
alarm needs a phone. The plant brings an Alertmanager with Telegram or
|
||||||
|
LINE and SMS receivers; `control`'s vmalert can point at it too.
|
||||||
|
- **Off-site backup destination**: `control`'s disk is not sized for plant
|
||||||
|
images and audio. Add a Hetzner Storage Box or a storage VPS as a second
|
||||||
|
`borgbackup` destination (the clan service supports several per client).
|
||||||
|
- **Router module**: three small extensions, listed under Networks.
|
||||||
|
|
||||||
## Design decisions
|
## Design decisions
|
||||||
|
|
||||||
1. **One clan, one repo, rebuildable from git.** Machine configuration,
|
1. **One clan, one repo, rebuildable from git.** Plant machines are entries
|
||||||
service placement, mesh networking, backups, host monitoring and
|
in `clan.nix`'s `fleet` set with a `machines/<name>/` directory each
|
||||||
secrets (clan vars, sops-encrypted) live in one flake. A failed machine
|
(`configuration.nix`, `disko.nix`, `facter.json`), like every machine
|
||||||
is replaced with `clan machines install <name>` from a fresh disk; a
|
already there. A failed box is replaced from a fresh disk with
|
||||||
configuration change is `clan machines update`. Nothing is configured by
|
`clan machines install`; a change is `clan machines update`. Nothing is
|
||||||
hand on a running box.
|
configured by hand on a running machine.
|
||||||
2. **One relational database for everything that has identity.**
|
2. **Two stores, by shape of the data.** Everything with an identity
|
||||||
PostgreSQL with TimescaleDB holds the genealogy, orders, gates, QC
|
(orders, gates, genealogy, lots, press runs, per-cycle rows, QC
|
||||||
results, per-cycle press data, environment history and energy history.
|
verdicts, events) lives in PostgreSQL on the plant core. Everything
|
||||||
Joining "this record" to "the mold temperature on that cycle" and to
|
that is a time series (1 Hz machine tags, zone environment, energy,
|
||||||
"the humidity in the press hall that hour" is a query, not an export.
|
water) lives in a plant-local VictoriaMetrics, the same engine and
|
||||||
Host and infrastructure metrics (CPU, disk, systemd, journals) go to
|
modules the fleet already runs on `control`, so dashboards, PromQL and
|
||||||
the separate Prometheus/Loki pair that the clan monitoring service
|
vmalert rules carry over unchanged. Per-cycle rows carry a snapshot of
|
||||||
provides; they are not process data.
|
the zone environment and the key press values, so the relational join
|
||||||
|
"this record, that cycle, those conditions" never needs the time-series
|
||||||
|
store; the curve behind the snapshot is one PromQL range query away.
|
||||||
|
(TimescaleDB in PostgreSQL is the fallback if that split proves
|
||||||
|
awkward; it is not the starting point.)
|
||||||
3. **MQTT is the plant bus, Telegraf is the universal collector.** Every
|
3. **MQTT is the plant bus, Telegraf is the universal collector.** Every
|
||||||
machine, meter and sensor is read by a Telegraf instance on an edge
|
machine, meter and sensor is read by a Telegraf instance on the edge
|
||||||
collector near it (Modbus, OPC UA, Siemens S7 and MQTT inputs are
|
collector nearest it (Modbus, OPC UA, Siemens S7 and MQTT inputs are
|
||||||
stock plugins) and published to the broker on the core server. The
|
stock plugins) and published to Mosquitto on the core. On the core,
|
||||||
core side persists everything to TimescaleDB with the same tool. Custom
|
Telegraf writes the stream to VictoriaMetrics (InfluxDB line protocol,
|
||||||
code exists only where no plugin does (vision results, instrument CSV
|
native to VM) and the factory application subscribes to the event
|
||||||
ingestion, the audio QC pipeline).
|
topics (cycle complete, alarm, instrument result) and writes rows.
|
||||||
|
Custom code exists only where no plugin does (vision results,
|
||||||
|
instrument CSV ingestion, the audio QC pipeline).
|
||||||
4. **Read-only toward machines.** The data platform never writes to a PLC
|
4. **Read-only toward machines.** The data platform never writes to a PLC
|
||||||
or an instrument. Control, safety and interlocks (fume extraction, steam
|
or an instrument. Control, safety and interlocks (fume extraction, steam
|
||||||
shutoff, boiler safety chain) stay in the vendor PLCs and hard wiring,
|
shutoff, boiler safety chain) stay in the vendor PLCs and hard wiring,
|
||||||
as [facility security](facility-security.md) already requires.
|
as [facility security](facility-security.md) already requires.
|
||||||
5. **Join keys are counters, not clocks.** Every press cycle carries the
|
5. **Join keys are counters, not clocks.** Every press cycle carries the
|
||||||
machine's own cycle counter; every instrument result carries the part
|
machine's own cycle counter; every instrument result carries the part
|
||||||
serial it was read from. Wall-clock time is recorded (UTC, NTP from the
|
serial it was read from. Wall-clock time is recorded (UTC, chrony from
|
||||||
router) but is never the thing two systems are joined on.
|
the fleet baseline) but is never what two systems are joined on.
|
||||||
6. **Append-only, hash-chained.** Process events, gate approvals and QC
|
6. **Append-only, hash-chained.** Process events, gate approvals and QC
|
||||||
verdicts are written once and never updated; corrections are new events
|
verdicts are written once and never updated; corrections are new events
|
||||||
that reference the old. Each event carries the hash of the previous one
|
that reference the old. Each event carries the hash of the previous one
|
||||||
@@ -55,55 +95,65 @@ NixOS estate and never host a service of ours.
|
|||||||
7. **The customer portal is a view, not a copy.** It reads the same
|
7. **The customer portal is a view, not a copy.** It reads the same
|
||||||
database through the same application with a customer role; there is
|
database through the same application with a customer role; there is
|
||||||
no exported report to keep in sync.
|
no exported report to keep in sync.
|
||||||
|
8. **The plant runs without the internet.** Everything that pressing,
|
||||||
|
QC and traceability need is on site. A WAN outage stops only the
|
||||||
|
customer portal, off-site backup, fleet monitoring and remote support,
|
||||||
|
and all four catch up when it returns.
|
||||||
|
|
||||||
## The systems on one page
|
## The systems on one page
|
||||||
|
|
||||||
| System | What it does | Runs on | Phase |
|
| System | What it does | Runs on | Phase |
|
||||||
|---|---|---|---|
|
|---|---|---|---|
|
||||||
| Network and firewall | VLAN zoning (OT, sensors, servers, stations, office, CCTV, guest), dual WAN, NTP, DHCP/DNS | `router-1` (NixOS, nftables) plus managed switches | Build |
|
| Site gateway | PPPoE WAN, VLAN zoning, DHCP/DNS, NTP for the site, internal TLS proxy, CrowdSec | `gw-<site>-1` (existing `cnx.router` module) | Build |
|
||||||
| Clan fleet | Inventory of every NixOS machine, ZeroTier mesh, SSH and user management, secrets, backups, host monitoring | git repo, applied to all machines | Now (dev), Build (plant) |
|
| Plant core | PostgreSQL, Mosquitto, Telegraf persister, VictoriaMetrics + vmalert + Grafana, Alertmanager, factory application, file datasets on ZFS | `vinyl-core` | Build |
|
||||||
| Plant data platform | PostgreSQL + TimescaleDB, MQTT broker, Telegraf persister, Grafana, S3-compatible object storage | `core-1` | Build |
|
| Factory application | Orders, gates, genealogy, materials, press runs, QC verdicts, packaging, fulfillment, customer portal, audit log | `vinyl-core` | Build (v1), Launch (v2) |
|
||||||
| Factory application | Orders, gates, genealogy, materials, press runs, QC verdicts, packaging, fulfillment, customer portal, audit log | `core-1` | Build (v1), Launch (v2) |
|
| Edge collectors | Telegraf per machine zone, disk-backed store-and-forward, NTP to the OT segment, vision result receiver | `vinyl-edge-press`, `vinyl-edge-util`, `vinyl-edge-galv` | Build, Expand |
|
||||||
| Edge collectors | Telegraf per machine zone, local store-and-forward, vision result receiver | `edge-press`, `edge-utility`, `edge-galvanics` | Build, Expand |
|
| Environmental monitoring | Zone temperature, humidity, PM, differential pressure; alarms; correlation with production | RS485 loops into the edge collectors | Build |
|
||||||
| Environmental monitoring | Zone temperature, humidity, PM, differential pressure; alarms; correlation with production | sensors on RS485 loops into `edge-utility` and `edge-press` | Build |
|
|
||||||
| Machine telemetry | Presses, extruders, hydraulics, boiler, chiller, compressor, heat pump, HVAC, PV, BESS, energy and water meters | edge collectors | Build |
|
| Machine telemetry | Presses, extruders, hydraulics, boiler, chiller, compressor, heat pump, HVAC, PV, BESS, energy and water meters | edge collectors | Build |
|
||||||
| QC instrument integration | Optical inspection results and images, metrology CSV ingestion, PVC lab entries, audio QC scores, packaging scans | stations plus `edge-press` | Launch, Expand |
|
| QC instrument integration | Optical inspection results and images, metrology CSV ingestion, PVC lab entries, audio QC scores, packaging scans | stations plus `vinyl-edge-press` | Launch, Expand |
|
||||||
| Station kiosks | Badge check-in and scanning at each manual step; kiosk browser on the factory application | `st-*` machines | Build |
|
| Station kiosks | Badge check-in and scanning at each manual step; kiosk browser on the factory application | `vinyl-st-*` | Build |
|
||||||
| Observability and alerting | Process alarms (Grafana on TimescaleDB), host alarms (clan monitoring), routing to phones, data-silence alarms | `core-1` | Build |
|
| Process alerting | Environment, utilities, reject rate, stamper life, PV/BESS, fire and BESS detection contacts, UPS, data silence; delivered to phones | `vinyl-core` (vmalert + Alertmanager) | Build |
|
||||||
| Backup and DR | ZFS snapshots, Borg to `backup-1` and off-site, PostgreSQL point-in-time recovery, restore drills | `backup-1`, `vps-1` | Build |
|
| Fleet monitoring | Host metrics, journals, host alerts for every plant machine | `control` (existing) | Build |
|
||||||
| Identity | OIDC single sign-on for staff, badge IDs for operators at stations, role model for customers | `core-1` (Pocket ID) | Build |
|
| Backup and DR | ZFS snapshots and replication, Borg to the plant backup server and off site, PostgreSQL point-in-time recovery, restore drills | `vinyl-backup`, off-site destination | Build |
|
||||||
| Client audio vault | Encrypted, isolated storage for pre-release audio with checksums and access logging | `core-1` (separate dataset) | Build |
|
| Identity | Staff sign-on (OIDC), badge IDs for operators at stations, customer role | `vinyl-core` | Build |
|
||||||
| Site systems integration | Access-control door events, fire panel and BESS detection contacts, UPS state, CCTV | `edge-utility`, optional `nvr-1` | Build |
|
| Client audio vault | Encrypted, isolated dataset for pre-release audio with checksums and access logging | `vinyl-core` | Build |
|
||||||
| Off-site node | ZeroTier moon with a public IP, off-site backup target, public reverse proxy for the portal | `vps-1` | Build |
|
| Site systems integration | Access-control door events, fire panel and BESS detection contacts, UPS state | `vinyl-edge-util` | Build |
|
||||||
|
| Customer portal, public | TLS termination and forwarding over the mesh to the plant core | `web01` (existing) | Launch |
|
||||||
|
| CCTV | Recording on its own VLAN | vendor NVR appliance, or `vinyl-nvr` (Frigate) if wanted | Build |
|
||||||
|
|
||||||
## Architecture
|
## Architecture
|
||||||
|
|
||||||
```mermaid
|
```mermaid
|
||||||
flowchart LR
|
flowchart LR
|
||||||
subgraph L0[Field]
|
subgraph L0[Field, isolated OT segments]
|
||||||
PLC[Press and extruder PLCs<br/>OPC UA / S7]
|
PLC[Press and extruder PLCs<br/>OPC UA / S7]
|
||||||
UT[Boiler, chiller, compressor,<br/>heat pump, HVAC<br/>Modbus / BACnet]
|
UT[Boiler, chiller, compressor,<br/>heat pump, HVAC<br/>Modbus / BACnet]
|
||||||
EN[Energy meters, Deye inverters,<br/>BESS, water meters<br/>Modbus / pulse]
|
EN[Energy meters, Deye inverters,<br/>BESS, water meters<br/>Modbus / pulse]
|
||||||
ENV[Zone T / RH / PM / dP sensors<br/>Modbus RTU]
|
ENV[Zone T / RH / PM / dP sensors<br/>Modbus RTU]
|
||||||
GV[Rectifiers, bath sensors<br/>Modbus]
|
GV[Rectifiers, bath sensors<br/>Modbus]
|
||||||
VIS[Vision controller<br/>TCP results, FTP images]
|
VIS[Vision controller<br/>TCP results, SFTP images]
|
||||||
INST[Keyence, XRF, lab instruments<br/>CSV export]
|
INST[Keyence, XRF, lab instruments<br/>CSV export]
|
||||||
end
|
end
|
||||||
subgraph L1[Edge, NixOS]
|
subgraph L1[Edge, NixOS, dual-homed]
|
||||||
EP[edge-press<br/>Telegraf + vision receiver]
|
EP[vinyl-edge-press<br/>Telegraf + vision receiver]
|
||||||
EU[edge-utility<br/>Telegraf]
|
EU[vinyl-edge-util<br/>Telegraf + dry-contact I/O]
|
||||||
EG[edge-galvanics<br/>Telegraf]
|
EG[vinyl-edge-galv<br/>Telegraf]
|
||||||
ST[st-* stations<br/>kiosk, scanners, ingestion]
|
ST[vinyl-st-* stations<br/>kiosk, scanners, ingestion]
|
||||||
end
|
end
|
||||||
subgraph L2[Core, NixOS]
|
subgraph L2[Plant core, NixOS, servers VLAN]
|
||||||
MQ[MQTT broker]
|
MQ[Mosquitto]
|
||||||
DB[(PostgreSQL + TimescaleDB)]
|
VM[(VictoriaMetrics<br/>vmalert, Grafana)]
|
||||||
OBJ[(Object storage)]
|
DB[(PostgreSQL)]
|
||||||
APP[Factory application]
|
APP[Factory application]
|
||||||
GF[Grafana + alerting]
|
AM[Alertmanager]
|
||||||
end
|
end
|
||||||
subgraph L3[Outside]
|
subgraph GW[gw-site-1]
|
||||||
VPS[vps-1: moon, backup, proxy]
|
PX[Caddy internal proxy<br/>factory.site1.cnx.network]
|
||||||
|
end
|
||||||
|
subgraph L3[Fleet, Hetzner, over the mesh]
|
||||||
|
CTL[control: node metrics,<br/>journals, host alerts]
|
||||||
|
WEB[web01: public proxy]
|
||||||
|
BK[off-site borg destination]
|
||||||
CUST[Customer portal]
|
CUST[Customer portal]
|
||||||
PH[Phones: alerts]
|
PH[Phones: alerts]
|
||||||
end
|
end
|
||||||
@@ -117,146 +167,208 @@ flowchart LR
|
|||||||
EP --> MQ
|
EP --> MQ
|
||||||
EU --> MQ
|
EU --> MQ
|
||||||
EG --> MQ
|
EG --> MQ
|
||||||
ST --> APP
|
MQ --> VM
|
||||||
MQ --> DB
|
|
||||||
MQ --> APP
|
MQ --> APP
|
||||||
APP --> DB
|
APP --> DB
|
||||||
APP --> OBJ
|
ST --> PX --> APP
|
||||||
EP --> OBJ
|
VM --> AM --> PH
|
||||||
DB --> GF
|
APP -.mesh.-> WEB --> CUST
|
||||||
GF --> PH
|
L2 -.mesh.-> CTL
|
||||||
APP --> VPS --> CUST
|
L2 -.mesh.-> BK
|
||||||
```
|
```
|
||||||
|
|
||||||
Three rules keep this simple: field devices talk only to their edge
|
Three rules keep this simple: field devices sit on isolated OT segments
|
||||||
collector (they are on VLANs with no route anywhere else); edge collectors
|
whose only other member is their edge collector; edge collectors publish to
|
||||||
talk only to the broker and object storage; the application and Grafana
|
the core and nothing else; stations and office clients reach the
|
||||||
talk only to the database, the broker and object storage. The VPS reaches
|
application only through the gateway's proxy. Everything that leaves the
|
||||||
the core over the ZeroTier mesh, never over an open port.
|
site rides the ZeroTier mesh, never an open port.
|
||||||
|
|
||||||
## Machines
|
## Machines
|
||||||
|
|
||||||
All NixOS, all in the clan inventory. Hardware classes are planning
|
All NixOS, all entries in the clan inventory. Names follow the fleet
|
||||||
positions; models are chosen at purchase.
|
convention (`gw-<city>-<n>` for gateways, short role names for servers)
|
||||||
|
with a `vinyl-` prefix so the plant's machines are recognisable in a
|
||||||
|
multi-site inventory. `<site>` is the city code chosen at site selection;
|
||||||
|
Mueang Chi is in Lamphun province, so `lpn` is the working assumption and
|
||||||
|
the gateway is `gw-lpn-1`, giving internal names under `*.lpn1.cnx.network`.
|
||||||
|
Hardware classes are planning positions; models are chosen at purchase.
|
||||||
|
|
||||||
| Machine | Role | Hardware class | Where | Clan tags |
|
| Machine | Role | Hardware class | Where |
|
||||||
|---|---|---|---|---|
|
|---|---|---|---|
|
||||||
| `router-1` | Firewall, VLANs, DHCP/DNS, NTP (chrony), dual WAN failover | fanless x86, 4+ NICs | IT room | `core` |
|
| `gw-lpn-1` | Site gateway: `cnx.router` with the plant VLANs, internal proxy for the factory application and Grafana, NTP for the site | Topton 1U N300, 4x 2.5G (fleet standard); a 10G SFP+ variant if the core server link warrants it | IT room |
|
||||||
| `core-1` | PostgreSQL + TimescaleDB, Mosquitto, Telegraf persister, factory app, Grafana, Garage object storage, Pocket ID, Caddy | 1U/2U server, ECC RAM 64 to 128 GB, mirrored NVMe for OS and database, HDD pool for objects, dual PSU on UPS | IT room | `core`, `db` |
|
| `vinyl-core` | PostgreSQL, Mosquitto, Telegraf persister, VictoriaMetrics + vmalert + Grafana, Alertmanager, factory application, ZFS datasets for files (audio captures, inspection images, metrology raw data, CoA scans, client audio) | 1U/2U server, ECC RAM 64 to 128 GB, mirrored NVMe for OS and database, HDD mirror or raidz for files, dual PSU on UPS | IT room |
|
||||||
| `backup-1` | Borg server, PostgreSQL streaming replica, second Garage node, ZFS receive target | tower or 2U, large HDD pool | separate room from `core-1` (archive side of the building) | `core`, `backup` |
|
| `vinyl-backup` | Borg server for the plant clients, ZFS receive target for `vinyl-core`'s datasets, PostgreSQL streaming replica, pgBackRest repository | tower or 2U, large HDD pool | separate room from `vinyl-core` (archive side of the building) |
|
||||||
| `vps-1` | ZeroTier moon (public IP), off-site Borg destination, third Garage node, reverse proxy for the customer portal | small cloud VPS with block storage, outside Thailand or in Bangkok, decision open | cloud | `offsite` |
|
| `vinyl-edge-press` | Telegraf (OPC UA / S7 to presses and extruders, Modbus to hydraulics and label oven), vision result receiver, SFTP target for inspection images, chrony serving the OT segment, disk-backed MQTT buffer | fanless DIN-rail IPC, 2 LAN, 2 to 4 RS485 | press hall control cabinet |
|
||||||
| `edge-press` | Telegraf (OPC UA / S7 to the presses and extruders, Modbus to hydraulics and label oven), vision result receiver, disk-backed buffer | fanless DIN-rail IPC, 2 LAN, 2 to 4 RS485 | press hall control cabinet | `edge` |
|
| `vinyl-edge-util` | Telegraf (Modbus to boiler, chiller, compressor, heat pump, energy meters, inverters, BESS; BACnet or Modbus to the HVAC BMS), zone environment loops, dry-contact I/O for fire panel, BESS detection and UPS | same class, more RS485 | electrical room or utility yard cabinet |
|
||||||
| `edge-utility` | Telegraf (Modbus to boiler, chiller, compressor, heat pump, energy meters, inverters, BESS, water; BACnet or Modbus to the HVAC BMS), zone environment loops, dry-contact I/O for fire panel, BESS detection and UPS | same class, more RS485 | electrical room or utility yard cabinet | `edge` |
|
| `vinyl-edge-galv` | Telegraf (rectifiers, bath sensors, extraction status) | same class, corrosion-protected enclosure outside the wet area | galvanics service corridor (Expand phase) |
|
||||||
| `edge-galvanics` | Telegraf (rectifiers, bath sensors, extraction status) | same class, corrosion-protected enclosure outside the wet area | galvanics service corridor | `edge` (Expand phase) |
|
| `vinyl-st-cutting` | Session log entry, lacquer registration, scribe ID | mini PC, touch screen, badge reader | cutting room |
|
||||||
| `st-intake` | Office workstation for audio intake and gates (plain browser; not a kiosk) | any NixOS desktop | office | `station` |
|
| `vinyl-st-press1`, `vinyl-st-press2` | Operator check-in, stamper mount/unmount scan, PVC lot and label lot scan, test pressing hold, reject reasons | mini PC, touch screen, badge reader, 2D scanner | at each press |
|
||||||
| `st-cutting` | Session log entry, lacquer registration, scribe ID | mini PC, touch screen, badge reader | cutting room | `station` |
|
| `vinyl-st-lab` | PVC lot gate entry; reads instruments with serial export, manual entry otherwise; CoA attachment | mini PC, RS232/USB to instruments | material lab |
|
||||||
| `st-press-1`, `st-press-2` | Operator check-in, stamper mount/unmount scan, PVC lot and label lot scan, test pressing hold, reject reasons | mini PC, touch screen, badge reader, 2D scanner | at each press | `station` |
|
| `vinyl-st-metrology` | SMB share the Keyence and XRF PCs export into; ingestion watcher; part serial scan | mini PC | metrology bench (Expand phase) |
|
||||||
| `st-lab` | PVC lot gate entry; reads instruments with serial export, manual entry otherwise; CoA attachment | mini PC, RS232/USB to instruments | material lab | `station` |
|
| `vinyl-st-audioqc` | Needle-drop capture and analysis pipeline | mini PC with audio interface, turntable, phono stage | listening/QC room (Expand phase) |
|
||||||
| `st-metrology` | SMB share the Keyence and XRF PCs export into; ingestion watcher; part serial scan | mini PC | metrology bench (Expand phase) | `station` |
|
| `vinyl-st-pack1` | Runout code camera read, jacket barcode scan, BOM check, barcode verifier | mini PC, camera, scanner, verifier | packaging |
|
||||||
| `st-audioqc` | Needle-drop capture and analysis pipeline | mini PC with audio interface, turntable, phono stage | listening/QC room (Expand phase) | `station` |
|
| `vinyl-st-ship` | Consignment assembly, carrier label and tracking capture | mini PC, label printer | shipping |
|
||||||
| `st-pack-1` | Runout code camera read, jacket barcode scan, BOM check, barcode verifier | mini PC, camera, scanner, verifier | packaging | `station` |
|
| `vinyl-nvr` | Frigate CCTV recording on the cctv VLAN (optional; a vendor NVR appliance is the alternative) | small server with GPU or Coral accelerator | IT room |
|
||||||
| `st-ship` | Consignment assembly, carrier label and tracking capture | mini PC, label printer | shipping | `station` |
|
|
||||||
| `nvr-1` | Frigate CCTV recording on its own VLAN (optional; a vendor NVR appliance is the alternative) | small server with GPU or Coral accelerator | IT room | `cctv` |
|
|
||||||
|
|
||||||
Stations run a kiosk browser (`cage` plus Firefox or Chromium) pointed at
|
Office audio intake and gate approvals happen from ordinary staff laptops
|
||||||
the factory application; badge readers and scanners are USB HID keyboard
|
on the `lan` VLAN through the same proxy; no dedicated machine. Stations
|
||||||
devices, so there is no driver work. Fifteen machines at launch, about
|
run a kiosk browser (`cage` plus Firefox or Chromium) pointed at the
|
||||||
twenty at maturity; every one is a few lines in the inventory.
|
application; badge readers and scanners are USB HID keyboard devices, so
|
||||||
|
there is no driver work. Fifteen plant machines at launch, about twenty at
|
||||||
|
maturity; every one is a directory and a line in the inventory.
|
||||||
|
|
||||||
## Networks
|
## Networks
|
||||||
|
|
||||||
| VLAN | Members | Rule |
|
The plant is site `<siteId>` (next free number in the fleet's site table;
|
||||||
|---|---|---|
|
`cnx` is 1 and the public-WiFi site is 2, so 3 is the working assumption)
|
||||||
| `ot-press` | press and extruder PLCs and HMIs, vision controller, `edge-press` | no internet, no route to other VLANs; `edge-press` is the only gateway |
|
and owns `10.<siteId>.0.0/16`. VLANs follow the fleet convention; the
|
||||||
| `ot-utility` | boiler, chiller, compressor, heat pump, HVAC BMS, meters, inverters, BESS BMS, `edge-utility` | same |
|
ids above 40 are proposals.
|
||||||
| `ot-galvanics` | rectifiers, bath transmitters, `edge-galvanics` | same |
|
|
||||||
| `sensors` | RS485 loops terminate on the edge collectors, so zone sensors have no IP presence; any IP sensor that is added lives here | no internet |
|
|
||||||
| `servers` | `core-1`, `backup-1`, `router-1` management | reachable from `stations`, `office`, edge collectors and the mesh |
|
|
||||||
| `stations` | `st-*` kiosks, instrument PCs (Keyence, vision setup laptop) | reach `core-1` only |
|
|
||||||
| `office` | staff laptops, printers | internet, `core-1` |
|
|
||||||
| `cctv` | cameras, `nvr-1` | no internet; NVR reachable from `office` by role |
|
|
||||||
| `guest` | visitors, vendor laptops | internet only |
|
|
||||||
| `mgmt` | switch and IPMI management interfaces | `router-1` and `core-1` admins only |
|
|
||||||
|
|
||||||
Vendor remote support (Newbilt and Pheenix both offer remote monitoring) goes
|
| VLAN | id | Members | `allowWan` | Rule |
|
||||||
through a jump account on `router-1` over the ZeroTier mesh, time-boxed and
|
|---|---|---|---|---|
|
||||||
logged, with a port forward to the one PLC HMI they need. No machine ever
|
| `mgmt` | 10 | switches, APs, Omada, IPMI, admin laptops on site | yes | fleet convention: trusted, reaches everything |
|
||||||
gets a vendor's own cellular router or cloud agent on the OT VLAN.
|
| `lan` | 20 | office laptops, printers | yes | proxy to factory app and Grafana, internet |
|
||||||
|
| `guest` | 30 | visitors, vendor laptops | yes | internet only |
|
||||||
|
| `servers` | 100 | `vinyl-core`, `vinyl-backup`, the servers-side NIC of every edge collector | yes (mesh, nix, journald, off-site backup) | no inbound from other VLANs; the gateway's own Caddy dials the app here |
|
||||||
|
| `stations` | 110 | `vinyl-st-*`, instrument PCs (Keyence, vision setup laptop), label printer | yes (mesh, deploys, journald) | proxy to the factory app only; `dhcp.reservations` for every station |
|
||||||
|
| `cctv` | 120 | cameras, NVR | no | reachable from `mgmt`; NVR UI via the proxy if wanted |
|
||||||
|
| `ot-press` | 210 | press and extruder PLCs and HMIs, vision controller, OT NIC of `vinyl-edge-press` | no | isolated segment, see below |
|
||||||
|
| `ot-util` | 220 | boiler, chiller, compressor, heat pump, HVAC BMS, meters, inverters, BESS BMS, OT NIC of `vinyl-edge-util` | no | isolated segment |
|
||||||
|
| `ot-galv` | 230 | rectifiers, bath transmitters, OT NIC of `vinyl-edge-galv` | no | isolated segment |
|
||||||
|
|
||||||
Dual WAN: fibre plus a 4G/5G modem on `router-1`, failover only. The plant
|
**OT segments are islands, not routes.** Each edge collector is dual-homed:
|
||||||
does not depend on the internet to run: everything in the tables above is
|
one NIC on `servers` (an access port on the cabinet switch), one NIC on
|
||||||
on site except `vps-1`, and the only things that stop when the internet
|
its OT segment. The OT segment lives on the cabinet's industrial switch;
|
||||||
drops are the customer portal and off-site backup.
|
if it must span cabinets it rides the building trunk as a VLAN with
|
||||||
|
`dhcp.enable = false` and `allowWan = false`, and the router's default
|
||||||
|
no-inter-VLAN policy keeps it closed. Either way the gateway forwards
|
||||||
|
nothing into or out of an OT segment; the collector is the only bridge,
|
||||||
|
and it only publishes. Zone sensors on RS485 loops terminate directly on
|
||||||
|
the collectors and have no IP presence at all. Cheap ESP32/MQTT sensor
|
||||||
|
nodes are acceptable for extra density in non-critical zones (on
|
||||||
|
`stations`, publishing to the core), never for alarmed zones.
|
||||||
|
|
||||||
## Clan inventory (sketch)
|
**Stations never route to `servers`.** They reach
|
||||||
|
`https://factory.lpn1.cnx.network`, which Blocky resolves to the gateway
|
||||||
|
and Caddy forwards to `vinyl-core` on the servers VLAN, with the real
|
||||||
|
wildcard certificate the router module already issues. `proxy.allowVlans`
|
||||||
|
gains `stations`. The same proxy serves `grafana.lpn1.cnx.network` to the
|
||||||
|
office. This keeps the fleet's trust model intact: no VLAN talks to
|
||||||
|
another VLAN; the router talks to its backends.
|
||||||
|
|
||||||
The plant clan in outline. Option names follow the clan release current at
|
Router module extensions the plant needs (small, and useful for the other
|
||||||
writing (26.05); check them against the pinned release before use, and
|
sites too):
|
||||||
expect the monitoring service to change, since it is still marked
|
|
||||||
experimental upstream.
|
|
||||||
|
|
||||||
```nix
|
1. **NTP served by the gateway** to every VLAN (chrony `allow` for the
|
||||||
{
|
site's `/16`, UDP 123 in the per-VLAN firewall set) so stations and
|
||||||
meta.name = "cnx-vinyl";
|
the NVR sync locally; today the gateway is only a chrony client.
|
||||||
meta.domain = "cnx"; # mesh-only TLD; hosts resolve as <name>.cnx
|
2. **Static-only VLANs**: a `dhcp.enable = false` VLAN should still
|
||||||
|
accept `reservations` semantics for documentation, or simply be
|
||||||
|
documented as address-by-hand; either is fine, decide when writing it.
|
||||||
|
3. **Second WAN**: a 4G/5G modem as failover for the PPPoE session
|
||||||
|
(`wan.backupInterface` with a metric and a health check). Not needed
|
||||||
|
for launch because the plant runs without the internet; needed before
|
||||||
|
the customer portal is promised as always-on.
|
||||||
|
|
||||||
inventory.machines = {
|
Vendor remote support (Newbilt and Pheenix both offer remote monitoring)
|
||||||
router-1 = { tags = [ "core" ]; };
|
goes through an admin's SSH port-forward across the mesh into the relevant
|
||||||
core-1 = { tags = [ "core" "db" "monitoring-server" ]; };
|
edge collector and from there to the one PLC HMI they need, time-boxed and
|
||||||
backup-1 = { tags = [ "core" "backup" ]; };
|
logged. No machine ever gets a vendor's own cellular router or cloud agent
|
||||||
vps-1 = { tags = [ "offsite" ]; };
|
on an OT segment.
|
||||||
edge-press = { tags = [ "edge" ]; };
|
|
||||||
edge-utility = { tags = [ "edge" ]; };
|
|
||||||
edge-galvanics = { tags = [ "edge" ]; };
|
|
||||||
st-cutting = { tags = [ "station" ]; };
|
|
||||||
st-press-1 = { tags = [ "station" ]; };
|
|
||||||
st-lab = { tags = [ "station" ]; };
|
|
||||||
st-pack-1 = { tags = [ "station" ]; };
|
|
||||||
st-ship = { tags = [ "station" ]; };
|
|
||||||
};
|
|
||||||
|
|
||||||
inventory.instances = {
|
## What changes in the clan repo
|
||||||
sshd.roles.server.tags.all = { };
|
|
||||||
admin.roles.default.tags.all = { }; # admin users and keys
|
|
||||||
|
|
||||||
zerotier = {
|
Following the "Adding a site" procedure in the clan runbook, plus the
|
||||||
roles.controller.machines.core-1 = { };
|
plant's own modules. Everything below is one pull request per machine
|
||||||
roles.moon.machines.vps-1.settings.stableEndpoints = [ "<public-ip>/9993" ];
|
class, in this order.
|
||||||
roles.peer.tags.all = { };
|
|
||||||
|
```
|
||||||
|
clan.nix
|
||||||
|
fleet: + gw-lpn-1, vinyl-core, vinyl-backup, vinyl-edge-press,
|
||||||
|
vinyl-edge-util, vinyl-st-press1, vinyl-st-lab,
|
||||||
|
vinyl-st-pack1, vinyl-st-ship (then the rest as they come)
|
||||||
|
borgbackup:
|
||||||
|
roles.server.machines.vinyl-backup = { };
|
||||||
|
roles.client.machines.vinyl-core.settings.destinations = {
|
||||||
|
plant = { repo = "borg@vinyl-backup:vinyl-core"; };
|
||||||
|
offsite = { repo = "<storage-box or bk host>:vinyl-core"; };
|
||||||
};
|
};
|
||||||
|
roles.client.machines.vinyl-edge-press = { ... plant only ... };
|
||||||
|
# side benefit: control can now back up its VictoriaMetrics TSDB to
|
||||||
|
# vinyl-backup, closing the open item in the clan TODO
|
||||||
|
(no `internet` entries: plant machines sit behind PPPoE like gw-cnx-1
|
||||||
|
and are reached over the mesh)
|
||||||
|
|
||||||
borgbackup = {
|
modules/mesh-hosts.nix + every plant machine in the name list
|
||||||
roles.server.machines.backup-1 = { };
|
modules/monitoring/server.nix
|
||||||
roles.server.machines.vps-1 = { };
|
+ node_exporter targets for every plant machine
|
||||||
roles.client.tags.core = { };
|
+ a second Grafana datasource "vinyl-vm" pointing
|
||||||
roles.client.tags.edge = { };
|
at [vinyl-core mesh]:8428 so fleet dashboards
|
||||||
};
|
can show plant series
|
||||||
|
modules/monitoring/alerts.nix
|
||||||
|
unchanged; host rules already cover new targets
|
||||||
|
machines/ns1/configuration.nix
|
||||||
|
+ dns-acme-gw-lpn-1-knot generator, keyFiles entry,
|
||||||
|
acl_acme_gw_lpn_1 scoped to _acme-challenge.lpn1
|
||||||
|
(copy the gw-cnx-1 blocks)
|
||||||
|
modules/dns/acme-gw-secret.nix
|
||||||
|
reused as-is with "gw-lpn-1"
|
||||||
|
modules/web-proxy.nix + virtualHosts."portal.<domain>" -> [vinyl-core mesh]:8080
|
||||||
|
(second cert + scoped TSIG key if <domain> is
|
||||||
|
not cnx.network, following the acme_web01 pattern)
|
||||||
|
|
||||||
monitoring = {
|
machines/gw-lpn-1/ copy of gw-cnx-1: site "lpn", siteId 3, the VLAN
|
||||||
roles.server.machines.core-1.settings.grafana.enable = true;
|
table above, proxy.services.factory and .grafana,
|
||||||
roles.client.tags.all = { };
|
proxy.allowVlans = [ "mgmt" "lan" "stations" ]
|
||||||
};
|
machines/vinyl-core/ imports modules/vinyl/{core,metrics,factory-app,
|
||||||
};
|
alertmanager}.nix + monitoring/exporters.nix
|
||||||
|
machines/vinyl-backup/ imports modules/vinyl/backup.nix + exporters.nix
|
||||||
|
machines/vinyl-edge-*/ imports modules/vinyl/edge.nix with the cabinet's
|
||||||
|
Telegraf inputs and the OT NIC config
|
||||||
|
machines/vinyl-st-*/ imports modules/vinyl/station.nix with the kiosk URL
|
||||||
|
|
||||||
# Our own NixOS modules, applied by tag or by machine:
|
modules/vinyl/core.nix PostgreSQL (ZFS dataset, pg_hba for the app and
|
||||||
# modules/edge-collector.nix Telegraf with the tag lists for that cabinet,
|
the replica), Mosquitto (per-client passwords from
|
||||||
# Mosquitto bridge with disk buffer
|
vars generators), Telegraf persister (MQTT in,
|
||||||
# modules/core-data.nix PostgreSQL + TimescaleDB, Mosquitto, Telegraf
|
VictoriaMetrics out), ZFS datasets and sanoid
|
||||||
# persister, Garage, Grafana, pgBackRest
|
modules/vinyl/metrics.nix VictoriaMetrics + vmalert + Grafana for the plant,
|
||||||
# modules/factory-app.nix the application service and its migrations
|
a sibling of monitoring/server.nix with the
|
||||||
# modules/station-kiosk.nix cage + browser, HID readers, auto-login
|
process rules and dashboards under
|
||||||
# modules/router.nix nftables zoning, VLAN interfaces, chrony,
|
modules/vinyl/dashboards/
|
||||||
# dual-WAN failover
|
modules/vinyl/alertmanager.nix
|
||||||
}
|
receivers: Telegram or LINE for the shift group,
|
||||||
|
SMS gateway for the critical set, email digest;
|
||||||
|
tokens from vars generators
|
||||||
|
modules/vinyl/factory-app.nix
|
||||||
|
the cnx-factory package as a flake input (like
|
||||||
|
nixos-mailserver is today), systemd service,
|
||||||
|
migrations on start, DB password from vars,
|
||||||
|
OIDC client secret from vars
|
||||||
|
modules/vinyl/edge.nix Telegraf with per-machine input lists, MQTT output
|
||||||
|
with disk buffer, chrony `allow` on the OT NIC,
|
||||||
|
networkd config for the two NICs, SFTP chroot for
|
||||||
|
vision images (press collector only)
|
||||||
|
modules/vinyl/station.nix cage + browser kiosk, auto-login, HID readers,
|
||||||
|
SMB share and ingestion watcher where needed
|
||||||
|
modules/vinyl/backup.nix borg server role settings, syncoid receive,
|
||||||
|
PostgreSQL replica, pgBackRest repo
|
||||||
|
modules/router/… the three extensions above
|
||||||
|
docs/src/vinyl.md the plant chapter of the runbook, + SUMMARY.md
|
||||||
```
|
```
|
||||||
|
|
||||||
What clan provides out of the box and we do not write ourselves: SSH and
|
Operational notes that already bit the fleet and apply here: `git add` a
|
||||||
admin user management, the ZeroTier mesh (controller on `core-1`, the VPS
|
new `machines/` directory before evaluating (untracked files are invisible
|
||||||
as a publicly reachable moon so the plant and remote consultants find each
|
to the flake); run `clan vars generate <machine>` (YubiKey) before the
|
||||||
other behind NAT), Borg backups with generated keys, host metrics and
|
first install and again after adding a generator; check `facter.json` for
|
||||||
journal shipping with Grafana on the server role, and sops-encrypted
|
the real NIC names after install; the `clan` wrapper in the dev shell
|
||||||
secrets per machine. What we write: the five modules listed in the sketch
|
updates machines sequentially so YubiKey prompts are not buried.
|
||||||
and the factory application itself.
|
|
||||||
|
Repository layout, decided: infrastructure lives in `cnx-network-clan`;
|
||||||
|
the factory application gets its own repository `cnx-factory` in the B4L
|
||||||
|
organisation and is consumed as a flake input; this repository stays
|
||||||
|
documents and links to both. That satisfies the README's promise that the
|
||||||
|
project repository "hosts the software" without mixing Nix, Rust and
|
||||||
|
planning prose in one history.
|
||||||
|
|
||||||
## Data acquisition, source by source
|
## Data acquisition, source by source
|
||||||
|
|
||||||
@@ -268,12 +380,12 @@ is bought, not retrofitted. Rates are planning values.
|
|||||||
|
|
||||||
| Source | Signals | Interface | Rate | Requirement to write into the RFQ |
|
| Source | Signals | Interface | Rate | Requirement to write into the RFQ |
|
||||||
|---|---|---|---|---|
|
|---|---|---|---|---|
|
||||||
| Newbilt Classic 12" automatic (Siemens PLC, vendor states SCADA/OPC UA) | cycle counter, machine state, cycle time, mold top/bottom temperatures, steam valve state, press pressure and force, extruder zone temperatures, screw speed, melt temperature and pressure, cake weight if measured, label feed state, alarm codes | OPC UA server on the PLC, read by Telegraf `inputs.opcua` | per cycle plus 1 Hz | OPC UA server licensed and enabled, full node list with units delivered with the machine, cycle counter exposed as a node, read access for our collector, no cloud agent required for warranty |
|
| Newbilt Classic 12" automatic (Siemens PLC, vendor states SCADA/OPC UA) | cycle counter, machine state, cycle time, mold top/bottom temperatures, steam valve state, press pressure and force, extruder zone temperatures, screw speed, melt temperature and pressure, cake weight if measured, label feed state, alarm codes | OPC UA server on the PLC, read by Telegraf `inputs.opcua` | per cycle plus 1 Hz | OPC UA server licensed and enabled, full node list with units delivered with the machine, cycle counter exposed as a node, read access for our collector, no cloud agent required for warranty, PLC clock accepting NTP |
|
||||||
| Newbilt HRP 12 semi-automatic and VEX 50 extruder (PLC type unconfirmed) | as above where the PLC has them; on a relay-logic machine at least press closed/open, steam on/off, cycle count | OPC UA or Siemens S7 (`inputs.s7comm`); fallback: our own 4 to 20 mA sensors on a Modbus TCP I/O module and a cycle count from the mold-closed limit switch | per cycle plus 1 Hz | state what the PLC is and which of the two paths applies; the fallback sensor set is priced separately |
|
| Newbilt HRP 12 semi-automatic and VEX 50 extruder (PLC type unconfirmed) | as above where the PLC has them; on a relay-logic machine at least press closed/open, steam on/off, cycle count | OPC UA or Siemens S7 (`inputs.s7comm`); fallback: our own 4 to 20 mA sensors on a Modbus TCP I/O module and a cycle count from the mold-closed limit switch | per cycle plus 1 Hz | state what the PLC is and which of the two paths applies; the fallback sensor set is priced separately |
|
||||||
| Pheenix AD12 (Beckhoff PLC, remote monitoring supported) | same tag family as the Classic | OPC UA (Beckhoff TF6100) or ADS; `inputs.opcua` | per cycle plus 1 Hz | OPC UA license included, tag list delivered, remote monitoring routed through our jump host |
|
| Pheenix AD12 (Beckhoff PLC, remote monitoring supported) | same tag family as the Classic | OPC UA (Beckhoff TF6100) or ADS; `inputs.opcua` | per cycle plus 1 Hz | OPC UA license included, tag list delivered, remote monitoring routed through our mesh, not the vendor's |
|
||||||
| Hydraulic aggregate | system pressure, oil temperature, tank level, filter differential pressure | via the press PLC if exposed, else own transmitters on the I/O module | 1 Hz | ask whether the aggregate's sensors are on the PLC |
|
| Hydraulic aggregate | system pressure, oil temperature, tank level, filter differential pressure | via the press PLC if exposed, else own transmitters on the I/O module | 1 Hz | ask whether the aggregate's sensors are on the PLC |
|
||||||
| Label dry oven | chamber temperature, timer state | Modbus if the controller has it, else a thermocouple on the I/O module | 1/min | |
|
| Label dry oven | chamber temperature, timer state | Modbus if the controller has it, else a thermocouple on the I/O module | 1/min | |
|
||||||
| PVC grinder and regrind scale | run state, batch weight | scale with RS232 to `st-press`, run contact to I/O | per batch | scale must have a serial output |
|
| PVC grinder and regrind scale | run state, batch weight | scale with RS232 to `vinyl-st-press1`, run contact to I/O | per batch | scale must have a serial output |
|
||||||
|
|
||||||
### Utilities and energy
|
### Utilities and energy
|
||||||
|
|
||||||
@@ -305,10 +417,9 @@ is bought, not retrofitted. Rates are planning values.
|
|||||||
|
|
||||||
Industrial RS485 Modbus RTU transmitters on wired loops to the nearest edge
|
Industrial RS485 Modbus RTU transmitters on wired loops to the nearest edge
|
||||||
collector, one reading per minute, with a reference-grade PM instrument in
|
collector, one reading per minute, with a reference-grade PM instrument in
|
||||||
the archive or cutting room to check the cheaper sensors against. Cheap
|
the archive or cutting room to check the cheaper sensors against. Every
|
||||||
ESP32/MQTT sensor nodes are acceptable for extra density in non-critical
|
zone alarm has two thresholds (warning, action) and a rate-of-change alarm
|
||||||
zones, never for the alarmed ones. Every zone alarm has two thresholds
|
for the archive.
|
||||||
(warning, action) and a rate-of-change alarm for the archive.
|
|
||||||
|
|
||||||
### Galvanics (Expand phase)
|
### Galvanics (Expand phase)
|
||||||
|
|
||||||
@@ -324,9 +435,9 @@ results are entered at a station against the bath ID.
|
|||||||
Access-control door events (badge ID, door, direction, time) from the
|
Access-control door events (badge ID, door, direction, time) from the
|
||||||
controller's API or export; fire alarm panel zone and fault contacts, BESS
|
controller's API or export; fire alarm panel zone and fault contacts, BESS
|
||||||
off-gas and early-smoke detection, UPS on-battery and low-battery (NUT on
|
off-gas and early-smoke detection, UPS on-battery and low-battery (NUT on
|
||||||
`core-1` talking to the UPS) as dry contacts on `edge-utility`. CCTV stays
|
`vinyl-core` talking to the UPS) as dry contacts on `vinyl-edge-util`.
|
||||||
on its own VLAN with its own retention; it is never joined to production
|
CCTV stays on its own VLAN with its own retention; it is never joined to
|
||||||
data.
|
production data.
|
||||||
|
|
||||||
### What produces no telemetry
|
### What produces no telemetry
|
||||||
|
|
||||||
@@ -340,21 +451,22 @@ logged by the sensors above.
|
|||||||
|
|
||||||
| Instrument | How results reach the database | Key | Open integration item |
|
| Instrument | How results reach the database | Key | Open integration item |
|
||||||
|---|---|---|---|
|
|---|---|---|---|
|
||||||
| Inline optical inspection at the press unloader (Keyence or Cognex class, custom integration) | vision controller sends one result string per record over TCP to a receiver on `edge-press`; images pushed by FTP/SFTP to object storage | press ID + cycle counter, passed from the PLC to the vision trigger | the cycle counter hand-off between PLC and vision controller is an integrator deliverable and an acceptance test |
|
| Inline optical inspection at the press unloader (Keyence or Cognex class, custom integration) | vision controller sends one result string per record over TCP to a receiver on `vinyl-edge-press`; images pushed by SFTP to the collector, synced to the core's image dataset | press ID + cycle counter, passed from the PLC to the vision trigger | the cycle counter hand-off between PLC and vision controller is an integrator deliverable and an acceptance test |
|
||||||
| Stamper metrology (Keyence VK-X, VR-6000, XRF gauge, profilometer) | vendor Windows PCs export CSV and raw 3D to an SMB share on `st-metrology`; a watcher parses and posts | back-side Data Matrix serial, scanned at the bench before measurement | export format per instrument confirmed with Keyence Thailand |
|
| Stamper metrology (Keyence VK-X, VR-6000, XRF gauge, profilometer) | vendor Windows PCs export CSV and raw 3D to an SMB share on `vinyl-st-metrology`; a watcher parses and posts | back-side Data Matrix serial, scanned at the bench before measurement | export format per instrument confirmed with Keyence Thailand |
|
||||||
| PVC material lab (moisture analyzer, spectrophotometer, balance, later torque rheometer, DSC, FTIR) | instruments with RS232/USB export are read at `st-lab`; the rest are typed in with the printout photographed; CoA PDF attached | compound lot ID (printed label scanned at intake) | which benchtop models have serial export |
|
| PVC material lab (moisture analyzer, spectrophotometer, balance, later torque rheometer, DSC, FTIR) | instruments with RS232/USB export are read at `vinyl-st-lab`; the rest are typed in with the printout photographed; CoA PDF attached | compound lot ID (printed label scanned at intake) | which benchtop models have serial export |
|
||||||
| Audio QC station | capture service on `st-audioqc` records the needle-drop (PipeWire, FLAC to object storage); analysis pipeline computes spectral-envelope match to the source master, click/pop count, noise floor, channel balance; scores posted | record key (stamper + press + cycle + side), typed or picked from the run list | first-of-kind pipeline, developed in Expand phase against launch-phase recordings |
|
| Audio QC station | capture service on `vinyl-st-audioqc` records the needle-drop (PipeWire, FLAC to the core's capture dataset); analysis pipeline computes spectral-envelope match to the source master, click/pop count, noise floor, channel balance; scores posted | record key (stamper + press + cycle + side), typed or picked from the run list | first-of-kind pipeline, developed in Expand phase against launch-phase recordings |
|
||||||
| Packaging assembly check | camera with darkfield lighting reads the scribed dead-wax code (a handheld scanner will not read a scribed code on black vinyl reliably); handheld scanner reads the jacket barcode; barcode verifier grades it | order + record key | confirm dead-wax code readability with a sample before the packaging station is designed |
|
| Packaging assembly check | camera with darkfield lighting reads the scribed dead-wax code (a handheld scanner will not read a scribed code on black vinyl reliably); handheld scanner reads the jacket barcode; barcode verifier grades it | order + record key | confirm dead-wax code readability with a sample before the packaging station is designed |
|
||||||
| Label print inspection | same vision family as the record label check; result per label lot | label lot ID | shared with the record inspection budget |
|
| Label print inspection | same vision family as the record label check; result per label lot | label lot ID | shared with the record inspection budget |
|
||||||
|
|
||||||
## The factory application
|
## The factory application
|
||||||
|
|
||||||
Working name `cnx-factory`. Server-rendered web application in Rust (axum,
|
Working name `cnx-factory`, its own repository. Server-rendered web
|
||||||
SQLx, minijinja templates, HTMX) on PostgreSQL, the stack B4L already uses
|
application in Rust (axum, SQLx, minijinja templates, HTMX) on PostgreSQL,
|
||||||
for its other in-house tooling, with the same append-only ledger and
|
the stack B4L already uses for its other in-house tooling, with the same
|
||||||
hash-chained audit log pattern. It subscribes to the MQTT event topics
|
append-only ledger and hash-chained audit log pattern. It subscribes to
|
||||||
(cycle complete, machine alarm, instrument result) and owns every write to
|
the MQTT event topics (cycle complete, machine alarm, instrument result)
|
||||||
the identity tables; Telegraf owns the writes to the time-series tables.
|
and owns every write to the identity tables; Telegraf owns the writes to
|
||||||
|
VictoriaMetrics. Packaged as a flake so the clan repo pins it as an input.
|
||||||
|
|
||||||
Modules, in build order:
|
Modules, in build order:
|
||||||
|
|
||||||
@@ -377,8 +489,9 @@ Modules, in build order:
|
|||||||
lots with incoming QC.
|
lots with incoming QC.
|
||||||
7. **Press runs and cycles**: a run binds order, stamper pair, press,
|
7. **Press runs and cycles**: a run binds order, stamper pair, press,
|
||||||
operator, shift, PVC lot in the hopper, regrind batch, label lot; each
|
operator, shift, PVC lot in the hopper, regrind batch, label lot; each
|
||||||
cycle event from the PLC becomes a row keyed by press + counter; the
|
cycle event from the PLC becomes a row keyed by press + counter with
|
||||||
record key is derived from it per side.
|
the key press values and the zone environment snapshot; the record key
|
||||||
|
is derived from it per side.
|
||||||
8. **QC verdicts**: optical per record, audio per sampled record, lab per
|
8. **QC verdicts**: optical per record, audio per sampled record, lab per
|
||||||
lot, packaging per unit; reject reasons; test-pressing hold state.
|
lot, packaging per unit; reject reasons; test-pressing hold state.
|
||||||
9. **Finishing, packaging, fulfillment**: assembly checks, consignment
|
9. **Finishing, packaging, fulfillment**: assembly checks, consignment
|
||||||
@@ -388,16 +501,15 @@ Modules, in build order:
|
|||||||
one customer sees only its own orders; PDF export of the trace.
|
one customer sees only its own orders; PDF export of the trace.
|
||||||
11. **Reports and signals**: yield per stamper, reject rate drift, audio
|
11. **Reports and signals**: yield per stamper, reject rate drift, audio
|
||||||
score trend versus play count (the automatic retirement signal),
|
score trend versus play count (the automatic retirement signal),
|
||||||
energy per record, environment excursions overlaid on runs.
|
energy per record, environment excursions overlaid on runs (the
|
||||||
|
curves fetched from VictoriaMetrics for the run's window).
|
||||||
|
|
||||||
Core entities: `customer`, `order`, `release`, `side`, `audio_asset`,
|
Core entities: `customer`, `order`, `release`, `side`, `audio_asset`,
|
||||||
`gate_approval`, `session`, `lacquer`, `father`, `mother`, `stamper`,
|
`gate_approval`, `session`, `lacquer`, `father`, `mother`, `stamper`,
|
||||||
`stamper_measurement`, `press`, `press_run`, `press_cycle`, `record`,
|
`stamper_measurement`, `press`, `press_run`, `press_cycle`, `record`,
|
||||||
`optical_result`, `audio_result`, `pvc_lot`, `regrind_batch`, `label_lot`,
|
`optical_result`, `audio_result`, `pvc_lot`, `regrind_batch`, `label_lot`,
|
||||||
`carton_lot`, `lab_result`, `packaging_check`, `shipment`, `operator`,
|
`carton_lot`, `lab_result`, `packaging_check`, `shipment`, `operator`,
|
||||||
`shift`, `event` (the hash chain). Time-series hypertables: `telemetry`
|
`shift`, `event` (the hash chain).
|
||||||
(machine, tag, value), `environment` (zone, metric, value), `energy`
|
|
||||||
(meter, kWh, kW), `water`.
|
|
||||||
|
|
||||||
Stations use the same application in kiosk mode: an operator taps a badge
|
Stations use the same application in kiosk mode: an operator taps a badge
|
||||||
(the same card the access-control system issues, so one ID) and scans
|
(the same card the access-control system issues, so one ID) and scans
|
||||||
@@ -405,55 +517,64 @@ whatever the step asks for. No forms longer than one screen.
|
|||||||
|
|
||||||
## Observability and alerting
|
## Observability and alerting
|
||||||
|
|
||||||
Two tiers, one Grafana:
|
Two tiers, split by where the data is:
|
||||||
|
|
||||||
- **Process alarms** from TimescaleDB: zone environment excursions and
|
- **Process, on site** (`vinyl-core`: VictoriaMetrics, vmalert,
|
||||||
rate of change, boiler pressure and level, chiller return temperature,
|
Grafana, Alertmanager): zone environment excursions and rate of change,
|
||||||
compressed-air pressure, hydraulic pressure, reject rate per run above
|
boiler pressure and level, chiller return temperature, compressed-air
|
||||||
baseline, stamper approaching its play-count limit, PV or BESS faults,
|
pressure, hydraulic pressure, reject rate per run above baseline,
|
||||||
fire and BESS detection contacts, UPS on battery.
|
stamper approaching its play-count limit, PV or BESS faults, fire and
|
||||||
- **Infrastructure alarms** from the clan monitoring stack: host down,
|
BESS detection contacts, UPS on battery. Works with the WAN down.
|
||||||
disk, service failed, backup missed, certificate expiry.
|
- **Hosts, on the fleet** (`control`): node_exporter and journald from
|
||||||
|
every plant machine over the mesh, the existing `ScrapeTargetDown`,
|
||||||
|
`RootFilesystemFull`, `BackupJobFailed`, `BackupStale` rules apply to
|
||||||
|
them without changes.
|
||||||
- **Data-silence alarms** in both tiers: a collector that has published
|
- **Data-silence alarms** in both tiers: a collector that has published
|
||||||
nothing for five minutes is an alarm, whatever the last value was.
|
nothing for five minutes is an alarm, whatever the last value was.
|
||||||
|
|
||||||
Routing: Telegram or the LINE Messaging API for the shift group, email for
|
Routing: Telegram or the LINE Messaging API for the shift group, email
|
||||||
the daily digest, SMS through a Thai gateway for the critical set (boiler,
|
digest daily, SMS through a Thai gateway for the critical set (boiler,
|
||||||
fire, BESS, archive climate) with an on-call rota. The animated
|
fire, BESS, archive climate) with an on-call rota. `control`'s vmalert can
|
||||||
|
drop `notifier.blackhole` and point at the same Alertmanager over the
|
||||||
|
mesh, which closes the fleet's own alert-delivery item. The animated
|
||||||
[plant operation page](plant-operation.html) is the design target for the
|
[plant operation page](plant-operation.html) is the design target for the
|
||||||
live overview: once the telemetry tables exist it is fed from Grafana or
|
live overview: once the series exist it is fed from VictoriaMetrics
|
||||||
directly from the database instead of its simulation.
|
instead of its simulation.
|
||||||
|
|
||||||
## Backup, retention and recovery
|
## Backup, retention and recovery
|
||||||
|
|
||||||
- **Hourly ZFS snapshots** on `core-1` (sanoid), replicated to `backup-1`
|
- **Hourly ZFS snapshots** on `vinyl-core` (sanoid), replicated to
|
||||||
(syncoid).
|
`vinyl-backup` (syncoid) for the file datasets and the PostgreSQL data
|
||||||
- **Nightly Borg** from every `core` and `edge` machine to `backup-1` and
|
directory.
|
||||||
to `vps-1` (clan borgbackup, two destinations).
|
- **Nightly Borg** (clan `borgbackup`) from `vinyl-core` and the edge
|
||||||
|
collectors to `vinyl-backup`, and from `vinyl-core` to the off-site
|
||||||
|
destination as a second entry in `destinations`; repokey encryption as
|
||||||
|
the fleet already does.
|
||||||
- **PostgreSQL point-in-time recovery**: pgBackRest with WAL archiving to
|
- **PostgreSQL point-in-time recovery**: pgBackRest with WAL archiving to
|
||||||
object storage, replicated to the off-site node; a streaming replica on
|
`vinyl-backup`, its repository included in the off-site Borg set; a
|
||||||
`backup-1` for fast failover.
|
streaming replica on `vinyl-backup` for fast failover.
|
||||||
- **Object storage** (Garage) with three nodes: `core-1`, `backup-1`,
|
- **VictoriaMetrics**: `vmbackup` snapshots to `vinyl-backup` nightly; the
|
||||||
`vps-1`; audio captures, inspection images, metrology raw data and CoA
|
fleet's own open item (backing up `control`'s TSDB) gets a destination
|
||||||
scans survive the loss of any one node.
|
at the same time.
|
||||||
- **Configuration**: the clan repo in Gitea, mirrored off-site; any machine
|
- **Configuration**: the clan repo and `cnx-factory` in Gitea; any machine
|
||||||
is rebuilt from it.
|
is rebuilt from them.
|
||||||
- **Restore drill quarterly**: restore the database to a scratch VM and
|
- **Restore drill quarterly**: restore the database to a scratch VM and
|
||||||
open a random order's trace in the portal. A backup that has never been
|
open a random order's trace in the portal. A backup that has never been
|
||||||
restored does not count.
|
restored does not count. The `BackupStale` rule already watches the
|
||||||
|
timers.
|
||||||
|
|
||||||
| Data | Retention |
|
| Data | Retention |
|
||||||
|---|---|
|
|---|---|
|
||||||
| genealogy, orders, gates, QC verdicts, event log | life of the customer relationship, never deleted while the metal parts exist |
|
| genealogy, orders, gates, QC verdicts, event log | life of the customer relationship, never deleted while the metal parts exist |
|
||||||
| per-cycle press data | forever (small) |
|
| per-cycle press rows | forever (small) |
|
||||||
| 1 Hz machine telemetry | raw 2 years, then 1-minute aggregates forever |
|
| 1 Hz machine telemetry | 2 years in VictoriaMetrics (`retentionPeriod`); per-cycle rows carry the summary forever |
|
||||||
| zone environment | raw 5 years |
|
| zone environment | 5 years (separate VM retention filter, or a second small instance) |
|
||||||
| energy and water | forever (small) |
|
| energy and water | forever (small; also summarised per shift into PostgreSQL) |
|
||||||
| audio captures and inspection images | 2 years, longer for any record with a complaint |
|
| audio captures and inspection images | 2 years, longer for any record with a complaint |
|
||||||
| client audio | per contract; default deleted 12 months after final delivery, or on request |
|
| client audio | per contract; default deleted 12 months after final delivery, or on request |
|
||||||
| access-control events | 1 year |
|
| access-control events | 1 year |
|
||||||
| CCTV | 30 days |
|
| CCTV | 30 days |
|
||||||
| host logs and metrics | 90 days |
|
| host logs and metrics | fleet defaults: 30 d logs, 180 d metrics on `control` |
|
||||||
|
|
||||||
PDPA applies to badge events, CCTV and customer contact data: a written
|
PDPA applies to badge events, CCTV and customer contact data: a written
|
||||||
retention policy, role-based access, and export/deletion on request. The
|
retention policy, role-based access, and export/deletion on request. The
|
||||||
@@ -461,18 +582,24 @@ customer portal shows operator roles, never operator names.
|
|||||||
|
|
||||||
## Security
|
## Security
|
||||||
|
|
||||||
- OT VLANs have no internet and no inbound routes; edge collectors are the
|
- OT segments have no gateway interface and no internet; edge collectors
|
||||||
only bridge and they only publish.
|
are the only bridge and they only publish.
|
||||||
- Staff sign-on through Pocket ID (OIDC, passkeys) with roles: admin,
|
- Stations and office reach the application only through the gateway's
|
||||||
engineer, operator, sales, customer. Stations authenticate by badge for
|
Caddy, with the wildcard certificate the fleet already issues; the
|
||||||
attribution, not for privilege.
|
servers VLAN accepts nothing from other VLANs.
|
||||||
- Secrets only in clan vars; nothing in plain text in the repo.
|
- Staff sign-on through an OIDC provider on `vinyl-core` (Pocket ID,
|
||||||
|
passkeys; the fleet has no identity provider yet, so this is the first)
|
||||||
|
with roles: admin, engineer, operator, sales, customer. Stations
|
||||||
|
authenticate by badge for attribution, not for privilege.
|
||||||
|
- Secrets only in clan vars (YubiKey-gated, `admins` group); nothing in
|
||||||
|
plain text in either repo.
|
||||||
- Client audio: separate encrypted ZFS dataset, SFTP or portal upload with
|
- Client audio: separate encrypted ZFS dataset, SFTP or portal upload with
|
||||||
checksums, every read logged, a written policy sales can show a label.
|
checksums, every read logged, a written policy sales can show a label.
|
||||||
- UPS on `core-1`, `router-1`, the switches, the edge collectors and the
|
- UPS on `vinyl-core`, `gw-lpn-1`, the switches, the edge collectors and
|
||||||
press PLCs (already required by facility security); NUT triggers a clean
|
the press PLCs (already required by facility security); NUT triggers a
|
||||||
shutdown before the battery is exhausted.
|
clean shutdown before the battery is exhausted.
|
||||||
- Signed commits on the clan repo; deployments only from a reviewed branch.
|
- Admin access rides the mesh, as for every fleet machine; public SSH is
|
||||||
|
never opened.
|
||||||
|
|
||||||
## Procurement clauses
|
## Procurement clauses
|
||||||
|
|
||||||
@@ -481,7 +608,7 @@ To go into every RFQ that leaves from [roadmap](roadmap.md) items 4 to 8:
|
|||||||
1. **Presses (Newbilt, Pheenix)**: OPC UA (or S7/ADS) read access licensed
|
1. **Presses (Newbilt, Pheenix)**: OPC UA (or S7/ADS) read access licensed
|
||||||
and enabled; the full tag list with units and the cycle counter as a
|
and enabled; the full tag list with units and the cycle counter as a
|
||||||
tag; a defined hand-off of the cycle counter to the inspection trigger;
|
tag; a defined hand-off of the cycle counter to the inspection trigger;
|
||||||
remote support through our jump host; no cloud agent as a warranty
|
remote support through our mesh; no cloud agent as a warranty
|
||||||
condition; PLC clock accepting NTP.
|
condition; PLC clock accepting NTP.
|
||||||
2. **Boiler, chiller, compressor, heat pump (Thai vendors)**: Modbus RTU or
|
2. **Boiler, chiller, compressor, heat pump (Thai vendors)**: Modbus RTU or
|
||||||
TCP with the register map delivered; alarm contacts wired to a terminal
|
TCP with the register map delivered; alarm contacts wired to a terminal
|
||||||
@@ -491,13 +618,16 @@ To go into every RFQ that leaves from [roadmap](roadmap.md) items 4 to 8:
|
|||||||
loops terminated in the edge cabinets.
|
loops terminated in the edge cabinets.
|
||||||
4. **Electrical contractor**: Modbus energy meters on the feeders listed
|
4. **Electrical contractor**: Modbus energy meters on the feeders listed
|
||||||
above; RS485 to the inverters and BESS BMS without cloud dongles;
|
above; RS485 to the inverters and BESS BMS without cloud dongles;
|
||||||
structured cabling and a VLAN-capable switch in every cabinet.
|
structured cabling, a VLAN-capable industrial switch in every cabinet,
|
||||||
|
and Omada-managed switches and APs for the building so the gateway's
|
||||||
|
existing Omada controller covers the site.
|
||||||
5. **Galvanics (Digital Matrix)**: what the rectifiers and control rings
|
5. **Galvanics (Digital Matrix)**: what the rectifiers and control rings
|
||||||
expose, and how; Modbus preferred.
|
expose, and how; Modbus preferred.
|
||||||
6. **Metrology (Keyence Thailand)**: confirmed CSV/3D export paths and
|
6. **Metrology (Keyence Thailand)**: confirmed CSV/3D export paths and
|
||||||
whether the instrument software can write to a network share unattended.
|
whether the instrument software can write to a network share unattended.
|
||||||
7. **Vision integrator**: result string format, image push, cycle counter
|
7. **Vision integrator**: result string format, image push over SFTP,
|
||||||
correlation, and an acceptance test defined in records not in features.
|
cycle counter correlation, and an acceptance test defined in records not
|
||||||
|
in features.
|
||||||
8. **Access control and fire**: API or export for door events; dry
|
8. **Access control and fire**: API or export for door events; dry
|
||||||
contacts for every alarm class; BESS detection outputs.
|
contacts for every alarm class; BESS detection outputs.
|
||||||
|
|
||||||
@@ -509,23 +639,26 @@ Aligned with the [roadmap](roadmap.md) phases.
|
|||||||
|
|
||||||
- Put the procurement clauses above into the Newbilt re-quote, the
|
- Put the procurement clauses above into the Newbilt re-quote, the
|
||||||
Pheenix, Digital Matrix and Thai utility RFQs.
|
Pheenix, Digital Matrix and Thai utility RFQs.
|
||||||
- Create the clan repo and a development clan of three small machines at
|
- In the clan repo: reserve the site id and VLAN table, write
|
||||||
the office: a `core-1` stand-in, one edge collector with a Modbus and
|
`modules/vinyl/{core,metrics,edge,station}.nix`, and stand up a dev
|
||||||
OPC UA simulator, one station. This proves the tooling before a single
|
trio at the Chiang Mai site behind `gw-cnx-1` (a `vinyl-core` stand-in,
|
||||||
plant machine exists.
|
one edge collector with a Modbus and OPC UA simulator, one station).
|
||||||
- Build the factory application v0 against a press simulator (the state
|
This proves the modules, the mesh path and the proxy before a single
|
||||||
machine in the plant operation page is the seed: same states, same
|
plant machine exists, and the machines move to the plant when it does.
|
||||||
cycle timing) so orders, gates, genealogy and press cycles can be
|
- Land the three router-module extensions on `gw-cnx-1` first, where they
|
||||||
exercised end to end without hardware.
|
are also useful.
|
||||||
- Decide the repository layout: this repository stays documents; the clan
|
- Start `cnx-factory` v0 against a press simulator (the state machine in
|
||||||
flake and the application get their own repositories in the same Gitea
|
the plant operation page is the seed: same states, same cycle timing) so
|
||||||
organisation, linked from here (see open questions).
|
orders, gates, genealogy and press cycles can be exercised end to end
|
||||||
|
without hardware; package it as a flake from the first commit.
|
||||||
|
- Wire the Alertmanager and one real receiver; point `control`'s vmalert
|
||||||
|
at it.
|
||||||
|
|
||||||
**Build and commission (roadmap Phase 3).**
|
**Build and commission (roadmap Phase 3).**
|
||||||
|
|
||||||
- Network, `router-1`, `core-1`, `backup-1` and `vps-1` installed before
|
- `gw-lpn-1`, switches, `vinyl-core` and `vinyl-backup` installed before
|
||||||
the machinery arrives, so vendor commissioning engineers plug into a
|
the machinery arrives, so vendor commissioning engineers plug into a
|
||||||
finished network.
|
finished network; ns1 gets the gateway's ACME key at the same time.
|
||||||
- Zone sensor loops, meters and edge cabinets installed by the electrical
|
- Zone sensor loops, meters and edge cabinets installed by the electrical
|
||||||
and HVAC contractors during fit-out; environment logging is live before
|
and HVAC contractors during fit-out; environment logging is live before
|
||||||
pressing starts, which gives a baseline.
|
pressing starts, which gives a baseline.
|
||||||
@@ -535,18 +668,19 @@ Aligned with the [roadmap](roadmap.md) phases.
|
|||||||
- Application v1 live: intake, gates, bridge-stamper genealogy, press runs
|
- Application v1 live: intake, gates, bridge-stamper genealogy, press runs
|
||||||
and cycles, PVC lot gate, packaging scan, shipments; stations at press,
|
and cycles, PVC lot gate, packaging scan, shipments; stations at press,
|
||||||
lab, packaging and shipping.
|
lab, packaging and shipping.
|
||||||
|
- Off-site backup destination live and a first restore drill done.
|
||||||
|
|
||||||
**Launch (roadmap Phase 4).**
|
**Launch (roadmap Phase 4).**
|
||||||
|
|
||||||
- Optical inspection integrated and correlated; reject reasons flowing.
|
- Optical inspection integrated and correlated; reject reasons flowing.
|
||||||
- Customer portal opened to the first labels.
|
- Customer portal opened to the first labels through `web01`.
|
||||||
- Energy and environment dashboards used for the first PV and HVAC
|
- Energy and environment dashboards used for the first PV and HVAC
|
||||||
tuning.
|
tuning.
|
||||||
|
|
||||||
**Expand (roadmap Phase 5).**
|
**Expand (roadmap Phase 5).**
|
||||||
|
|
||||||
- `edge-galvanics`, bath sensors, rectifier data, metrology ingestion at
|
- `vinyl-edge-galv`, bath sensors, rectifier data, metrology ingestion at
|
||||||
`st-metrology`; genealogy switches from bridged to in-house.
|
`vinyl-st-metrology`; genealogy switches from bridged to in-house.
|
||||||
- Audio QC station and pipeline; retirement signal live.
|
- Audio QC station and pipeline; retirement signal live.
|
||||||
- Automated press line joins the same collector with the same tag family.
|
- Automated press line joins the same collector with the same tag family.
|
||||||
- Biomass boiler on the same Modbus path as its predecessor.
|
- Biomass boiler on the same Modbus path as its predecessor.
|
||||||
@@ -555,21 +689,23 @@ Aligned with the [roadmap](roadmap.md) phases.
|
|||||||
|
|
||||||
Planning estimates, September 2026, excluding the QC instruments (those
|
Planning estimates, September 2026, excluding the QC instruments (those
|
||||||
are in quality automation) and excluding the vendors' OPC UA license
|
are in quality automation) and excluding the vendors' OPC UA license
|
||||||
options, which come back with the quotes.
|
options, which come back with the quotes. Fleet pieces already paid for
|
||||||
|
(`control`, `ns1`, `ns2`, `web01`, the mesh) cost the plant nothing extra.
|
||||||
|
|
||||||
| Block | Estimate (USD) |
|
| Block | Estimate (USD) |
|
||||||
|---|---|
|
|---|---|
|
||||||
| `core-1` and `backup-1` servers, UPS, rack | 8,000 to 15,000 |
|
| `gw-lpn-1` (Topton 1U, fleet standard) | 300 to 500 |
|
||||||
| `router-1`, managed switches (industrial in the cabinets), cabling allowance | 4,000 to 8,000 |
|
| `vinyl-core` and `vinyl-backup` servers, UPS, rack | 8,000 to 15,000 |
|
||||||
|
| Omada switches and APs for the building, industrial switches in the cabinets, cabling allowance | 4,000 to 8,000 |
|
||||||
| 3 edge collectors with I/O modules and enclosures | 3,000 to 6,000 |
|
| 3 edge collectors with I/O modules and enclosures | 3,000 to 6,000 |
|
||||||
| 8 station kiosks with readers, scanners, one barcode verifier, one darkfield camera | 8,000 to 15,000 |
|
| 8 station kiosks with readers, scanners, one barcode verifier, one darkfield camera | 8,000 to 15,000 |
|
||||||
| zone environment sensors (12 to 16 points), room dP, reference PM instrument | 4,000 to 8,000 |
|
| zone environment sensors (12 to 16 points), room dP, reference PM instrument | 4,000 to 8,000 |
|
||||||
| energy meters (10 feeders), water meters, level transmitters | 3,000 to 6,000 |
|
| energy meters (10 feeders), water meters, level transmitters | 3,000 to 6,000 |
|
||||||
| audio QC hardware (turntable, arm, cartridge, phono stage, interface) | 2,000 to 5,000 |
|
| audio QC hardware (turntable, arm, cartridge, phono stage, interface) | 2,000 to 5,000 |
|
||||||
| `vps-1` and off-site storage, per year | 500 to 1,500 |
|
| off-site backup storage, per year | 100 to 500 |
|
||||||
| **Hardware total** | **~32,000 to 64,000** |
|
| **Hardware total** | **~32,000 to 64,000** |
|
||||||
| Application development to v1 (orders through shipments, stations, portal) | 4 to 6 person-months |
|
| `cnx-factory` to v1 (orders through shipments, stations, portal) | 4 to 6 person-months |
|
||||||
| Clan fleet, modules and collectors to commissioning | 1 to 2 person-months |
|
| Clan modules, router extensions, collectors, dashboards and rules to commissioning | 1 to 2 person-months |
|
||||||
| Vision, metrology and audio pipeline integration (Launch and Expand) | 3 to 5 person-months, plus integrator fees in the vision quote |
|
| Vision, metrology and audio pipeline integration (Launch and Expand) | 3 to 5 person-months, plus integrator fees in the vision quote |
|
||||||
|
|
||||||
Headcount note: [scale](scale.md) lists no IT or automation role in the
|
Headcount note: [scale](scale.md) lists no IT or automation role in the
|
||||||
@@ -578,22 +714,22 @@ Build onward, part-time at launch; add it to the headcount.
|
|||||||
|
|
||||||
## Open questions
|
## Open questions
|
||||||
|
|
||||||
|
- Site code and id: `lpn` / 3 assumed; confirm when the site is chosen and
|
||||||
|
the fleet site table is updated.
|
||||||
- Semi-automatic press PLC: does the HRP 12 expose data, or is the sensor
|
- Semi-automatic press PLC: does the HRP 12 expose data, or is the sensor
|
||||||
fallback needed? (Ask in the Newbilt re-quote.)
|
fallback needed? (Ask in the Newbilt re-quote.)
|
||||||
- Cycle counter hand-off to the vision system: PLC output, network
|
- Cycle counter hand-off to the vision system: PLC output, network
|
||||||
message, or time correlation at the unloader? Decided with the vision
|
message, or time correlation at the unloader? Decided with the vision
|
||||||
integrator, tested at acceptance.
|
integrator, tested at acceptance.
|
||||||
- HVAC BMS protocol and who owns the zone sensors: HVAC contractor or us.
|
- HVAC BMS protocol and who owns the zone sensors: HVAC contractor or us.
|
||||||
- Where `vps-1` lives: outside Thailand (latency to the mesh, data
|
- Off-site backup destination: Hetzner Storage Box (cheapest) or a storage
|
||||||
residency for customer data) or a Bangkok provider.
|
VPS that is also a mesh peer (uniform tooling). Data residency for
|
||||||
- Portal availability: served through the mesh from `core-1` (down when
|
customer audio may argue for a Bangkok provider instead.
|
||||||
the plant's internet is down) or a read replica on `vps-1` (more moving
|
- Customer portal domain: the plant's brand domain (new zone on ns1/ns2,
|
||||||
parts). Start with the former.
|
second cert on `web01`) or a name under `cnx.network` for launch.
|
||||||
|
- Portal availability during a plant WAN outage: accept it (the portal is
|
||||||
|
a view of live data) or add a read replica on the fleet side later.
|
||||||
- Accounting and ERP: out of scope for the application; if an ERP is
|
- Accounting and ERP: out of scope for the application; if an ERP is
|
||||||
adopted later it references the same order IDs. Decide after launch.
|
adopted later it references the same order IDs. Decide after launch.
|
||||||
- Repository layout: documents here, `cnx-infra` (clan) and `cnx-factory`
|
|
||||||
(application) as separate repositories, or everything in one. The
|
|
||||||
README currently promises this repository will hold the software; a
|
|
||||||
link satisfies that.
|
|
||||||
- Dead-wax code readability on black and coloured vinyl with a camera:
|
- Dead-wax code readability on black and coloured vinyl with a camera:
|
||||||
test with samples before the packaging station is designed.
|
test with samples before the packaging station is designed.
|
||||||
Reference in new issue