Digital factory plan: build on the existing cnx-network clan
Rewrite docs/digital-factory.md against the fleet that already exists at git.b4l.co.th/B4L/cnx-network-clan instead of a plant-only clan: - The plant is one more site: gw-lpn-1 from the cnx.router module, plant machines in the same inventory, reached over the existing ZeroTier mesh (no VPS, no moon, no port forwards). - Fleet pieces reused as-is: control for host metrics, journals and host alerts; ns1/ns2 for the gateway wildcard cert; web01 as the public proxy for the customer portal; clan borgbackup with a plant server. - Process time series move from TimescaleDB to a plant-local VictoriaMetrics (same modules and rules as control); PostgreSQL keeps everything with identity. Object storage dropped for ZFS datasets. - VLAN table on the fleet addressing convention (siteId 3 assumed, ids above 40); OT segments as dual-homed islands behind the collectors; stations reach the app only through the gateway Caddy proxy. - New section listing every file that changes in the clan repo, the modules/vinyl/* to write, and three router-module extensions (NTP serving, static VLANs, second WAN). - Gaps the plant closes for the fleet: Alertmanager delivery, off-site backup destination, TSDB backup. - Repository layout decided: infra in cnx-network-clan, app in cnx-factory as a flake input, this repo stays documents. README bullet updated to match.
This commit is contained in:
1 parent
0fb60bcbb5
commit
ffcce42a51
2 files changed
+413
-276
No files matched your search
@@ -88,11 +88,12 @@ The detail lives in dedicated documents:
|
||||
shipment, and the requirements this sets for the factory software
|
||||
- [Digital factory systems plan](docs/digital-factory.md): every system
|
||||
that has to exist for environment, machine, QC and genealogy data to land
|
||||
in one database keyed to one record identity: the NixOS machine fleet
|
||||
managed as one Clan, networks and VLAN zoning, Telegraf/MQTT acquisition
|
||||
source by source, QC instrument integration, the factory application,
|
||||
alerting, backup, security, the data clauses for every RFQ, build order
|
||||
and rough cost
|
||||
in one database keyed to one record identity: the plant as one more site
|
||||
in B4L's existing NixOS fleet (the cnx-network clan: mesh, DNS, fleet
|
||||
monitoring, site gateway module, public proxy), what changes in that
|
||||
repo, VLAN zoning, Telegraf/MQTT acquisition source by source, QC
|
||||
instrument integration, the factory application, alerting, backup,
|
||||
security, the data clauses for every RFQ, build order and rough cost
|
||||
- [Quality automation](docs/quality-automation.md): stamper metrology
|
||||
(Keyence-class confocal, profiler, XRF), layered pressed-record QC (100%
|
||||
optical inspection, per-cycle press telemetry, sampled automated audio
|
||||
|
||||
+407
-271
@@ -9,44 +9,84 @@ genealogy all land in one place, keyed to one record identity, and can be
|
||||
shown to a customer. It is a planning position as of September 2026; every
|
||||
cost figure is an estimate until a quote replaces it.
|
||||
|
||||
**Standing decision: every service runs on NixOS, and the whole fleet is
|
||||
declared and deployed as one [Clan](https://clan.lol).** Servers, edge
|
||||
collectors, station kiosks, the router and the off-site VPS are all NixOS
|
||||
machines in a single inventory. Vendor instrument PCs (Keyence, vision
|
||||
controllers, PLC HMIs) are appliances, not servers: they export into the
|
||||
NixOS estate and never host a service of ours.
|
||||
**Standing decision: every service runs on NixOS, and the plant is one more
|
||||
site in the existing B4L fleet, the
|
||||
[cnx-network clan](https://git.b4l.co.th/B4L/cnx-network-clan).** That
|
||||
clan already runs the ZeroTier mesh, authoritative DNS, mail, fleet
|
||||
monitoring, backups, a public reverse proxy and the first site gateway, all
|
||||
declared in one repository and deployed with the clan CLI. The plant adds
|
||||
a gateway, a core server, a backup server, edge collectors and station
|
||||
kiosks to that inventory and reuses everything the fleet already provides.
|
||||
Nothing is built twice. Vendor instrument PCs (Keyence, vision controllers,
|
||||
PLC HMIs) are appliances, not servers: they export into the NixOS estate
|
||||
and never host a service of ours.
|
||||
|
||||
## What the fleet already provides
|
||||
|
||||
Read the clan's own runbook (`docs/` in the repo, served on `control`) for
|
||||
detail; this is what the plant plan leans on.
|
||||
|
||||
| Fleet piece | Where | What the plant gets from it |
|
||||
|---|---|---|
|
||||
| Clan repo, clan-core 26.05, sops vars gated by YubiKey, `admins` group applied to every machine automatically | git.b4l.co.th/B4L/cnx-network-clan | one inventory, one deploy path (`clan machines install` / `update`), secrets minted with `clan vars generate` |
|
||||
| ZeroTier mesh, controller on `control`, IPv6 ULA `/88`, `modules/mesh-hosts.nix` reads every peer's address from vars | `control` | admin SSH, deploys and scrapes for plant machines behind PPPoE NAT, exactly as `gw-cnx-1` is reached today; no port forwards, no VPS needed |
|
||||
| `modules/router/`: `cnx.router.*` on Topton 1U boxes: PPPoE WAN, VLAN-filtering bridge, nftables with no inter-VLAN traffic, Kea, Blocky, CrowdSec, Omada, iperf3, hourly speed test, Caddy internal proxy with a real wildcard `*.<site><n>.cnx.network` via DNS-01 | site gateways | the plant router is a copy of `machines/gw-cnx-1/` with its own VLANs; the internal proxy gives every station a browser-trusted `https://factory.<site>1.cnx.network` |
|
||||
| Addressing convention `10.<siteId>.<vlanId>.0/24`, VLAN ids 10 mgmt and 20 lan mandatory, 30 guest, 40 iot reserved | fleet-wide | the plant takes the next free `siteId` and adds its own VLANs above 40 |
|
||||
| VictoriaMetrics (180 d), VictoriaLogs (30 d), vmalert, Grafana, blackbox probes | `control` | node_exporter on every plant machine scraped over the mesh, journald shipped to VictoriaLogs, host alerts from the existing rules; process data stays on site (below) |
|
||||
| Knot DNS (`cnx.network`, `buildfor.life`, `cnx.email`) with per-consumer TSIG keys for ACME | `ns1`, `ns2` | the plant's public names and the gateway's wildcard cert; a brand domain for the customer portal is one zone file away |
|
||||
| `web01`: public Caddy with `*.cnx.network`, backends dialed over the mesh | Hetzner | the customer portal is one `virtualHosts` entry pointing at the plant core's mesh address, the same way `grafana.cnx.network` works now |
|
||||
| clan `borgbackup` service, `control` as server, repokey encryption, backups over the mesh | `control` | the pattern; the plant needs its own server because plant data is far larger than the DNSSEC keystore |
|
||||
| chrony everywhere, fixed-offset time zones (`Etc/GMT-7` for Thailand) | fleet baseline | plant machines inherit; edge collectors additionally serve NTP to the PLCs |
|
||||
| mdbook runbook in `docs/src/`, built and served on `control` | `control` | the plant's operational runbook goes there as a chapter; this document stays the planning source |
|
||||
|
||||
Known gaps in the fleet that the plant needs closed (all on the clan's own
|
||||
TODO list or small extensions to existing modules):
|
||||
|
||||
- **Alert delivery**: vmalert currently uses `notifier.blackhole`. A boiler
|
||||
alarm needs a phone. The plant brings an Alertmanager with Telegram or
|
||||
LINE and SMS receivers; `control`'s vmalert can point at it too.
|
||||
- **Off-site backup destination**: `control`'s disk is not sized for plant
|
||||
images and audio. Add a Hetzner Storage Box or a storage VPS as a second
|
||||
`borgbackup` destination (the clan service supports several per client).
|
||||
- **Router module**: three small extensions, listed under Networks.
|
||||
|
||||
## Design decisions
|
||||
|
||||
1. **One clan, one repo, rebuildable from git.** Machine configuration,
|
||||
service placement, mesh networking, backups, host monitoring and
|
||||
secrets (clan vars, sops-encrypted) live in one flake. A failed machine
|
||||
is replaced with `clan machines install <name>` from a fresh disk; a
|
||||
configuration change is `clan machines update`. Nothing is configured by
|
||||
hand on a running box.
|
||||
2. **One relational database for everything that has identity.**
|
||||
PostgreSQL with TimescaleDB holds the genealogy, orders, gates, QC
|
||||
results, per-cycle press data, environment history and energy history.
|
||||
Joining "this record" to "the mold temperature on that cycle" and to
|
||||
"the humidity in the press hall that hour" is a query, not an export.
|
||||
Host and infrastructure metrics (CPU, disk, systemd, journals) go to
|
||||
the separate Prometheus/Loki pair that the clan monitoring service
|
||||
provides; they are not process data.
|
||||
1. **One clan, one repo, rebuildable from git.** Plant machines are entries
|
||||
in `clan.nix`'s `fleet` set with a `machines/<name>/` directory each
|
||||
(`configuration.nix`, `disko.nix`, `facter.json`), like every machine
|
||||
already there. A failed box is replaced from a fresh disk with
|
||||
`clan machines install`; a change is `clan machines update`. Nothing is
|
||||
configured by hand on a running machine.
|
||||
2. **Two stores, by shape of the data.** Everything with an identity
|
||||
(orders, gates, genealogy, lots, press runs, per-cycle rows, QC
|
||||
verdicts, events) lives in PostgreSQL on the plant core. Everything
|
||||
that is a time series (1 Hz machine tags, zone environment, energy,
|
||||
water) lives in a plant-local VictoriaMetrics, the same engine and
|
||||
modules the fleet already runs on `control`, so dashboards, PromQL and
|
||||
vmalert rules carry over unchanged. Per-cycle rows carry a snapshot of
|
||||
the zone environment and the key press values, so the relational join
|
||||
"this record, that cycle, those conditions" never needs the time-series
|
||||
store; the curve behind the snapshot is one PromQL range query away.
|
||||
(TimescaleDB in PostgreSQL is the fallback if that split proves
|
||||
awkward; it is not the starting point.)
|
||||
3. **MQTT is the plant bus, Telegraf is the universal collector.** Every
|
||||
machine, meter and sensor is read by a Telegraf instance on an edge
|
||||
collector near it (Modbus, OPC UA, Siemens S7 and MQTT inputs are
|
||||
stock plugins) and published to the broker on the core server. The
|
||||
core side persists everything to TimescaleDB with the same tool. Custom
|
||||
code exists only where no plugin does (vision results, instrument CSV
|
||||
ingestion, the audio QC pipeline).
|
||||
machine, meter and sensor is read by a Telegraf instance on the edge
|
||||
collector nearest it (Modbus, OPC UA, Siemens S7 and MQTT inputs are
|
||||
stock plugins) and published to Mosquitto on the core. On the core,
|
||||
Telegraf writes the stream to VictoriaMetrics (InfluxDB line protocol,
|
||||
native to VM) and the factory application subscribes to the event
|
||||
topics (cycle complete, alarm, instrument result) and writes rows.
|
||||
Custom code exists only where no plugin does (vision results,
|
||||
instrument CSV ingestion, the audio QC pipeline).
|
||||
4. **Read-only toward machines.** The data platform never writes to a PLC
|
||||
or an instrument. Control, safety and interlocks (fume extraction, steam
|
||||
shutoff, boiler safety chain) stay in the vendor PLCs and hard wiring,
|
||||
as [facility security](facility-security.md) already requires.
|
||||
5. **Join keys are counters, not clocks.** Every press cycle carries the
|
||||
machine's own cycle counter; every instrument result carries the part
|
||||
serial it was read from. Wall-clock time is recorded (UTC, NTP from the
|
||||
router) but is never the thing two systems are joined on.
|
||||
serial it was read from. Wall-clock time is recorded (UTC, chrony from
|
||||
the fleet baseline) but is never what two systems are joined on.
|
||||
6. **Append-only, hash-chained.** Process events, gate approvals and QC
|
||||
verdicts are written once and never updated; corrections are new events
|
||||
that reference the old. Each event carries the hash of the previous one
|
||||
@@ -55,55 +95,65 @@ NixOS estate and never host a service of ours.
|
||||
7. **The customer portal is a view, not a copy.** It reads the same
|
||||
database through the same application with a customer role; there is
|
||||
no exported report to keep in sync.
|
||||
8. **The plant runs without the internet.** Everything that pressing,
|
||||
QC and traceability need is on site. A WAN outage stops only the
|
||||
customer portal, off-site backup, fleet monitoring and remote support,
|
||||
and all four catch up when it returns.
|
||||
|
||||
## The systems on one page
|
||||
|
||||
| System | What it does | Runs on | Phase |
|
||||
|---|---|---|---|
|
||||
| Network and firewall | VLAN zoning (OT, sensors, servers, stations, office, CCTV, guest), dual WAN, NTP, DHCP/DNS | `router-1` (NixOS, nftables) plus managed switches | Build |
|
||||
| Clan fleet | Inventory of every NixOS machine, ZeroTier mesh, SSH and user management, secrets, backups, host monitoring | git repo, applied to all machines | Now (dev), Build (plant) |
|
||||
| Plant data platform | PostgreSQL + TimescaleDB, MQTT broker, Telegraf persister, Grafana, S3-compatible object storage | `core-1` | Build |
|
||||
| Factory application | Orders, gates, genealogy, materials, press runs, QC verdicts, packaging, fulfillment, customer portal, audit log | `core-1` | Build (v1), Launch (v2) |
|
||||
| Edge collectors | Telegraf per machine zone, local store-and-forward, vision result receiver | `edge-press`, `edge-utility`, `edge-galvanics` | Build, Expand |
|
||||
| Environmental monitoring | Zone temperature, humidity, PM, differential pressure; alarms; correlation with production | sensors on RS485 loops into `edge-utility` and `edge-press` | Build |
|
||||
| Site gateway | PPPoE WAN, VLAN zoning, DHCP/DNS, NTP for the site, internal TLS proxy, CrowdSec | `gw-<site>-1` (existing `cnx.router` module) | Build |
|
||||
| Plant core | PostgreSQL, Mosquitto, Telegraf persister, VictoriaMetrics + vmalert + Grafana, Alertmanager, factory application, file datasets on ZFS | `vinyl-core` | Build |
|
||||
| Factory application | Orders, gates, genealogy, materials, press runs, QC verdicts, packaging, fulfillment, customer portal, audit log | `vinyl-core` | Build (v1), Launch (v2) |
|
||||
| Edge collectors | Telegraf per machine zone, disk-backed store-and-forward, NTP to the OT segment, vision result receiver | `vinyl-edge-press`, `vinyl-edge-util`, `vinyl-edge-galv` | Build, Expand |
|
||||
| Environmental monitoring | Zone temperature, humidity, PM, differential pressure; alarms; correlation with production | RS485 loops into the edge collectors | Build |
|
||||
| Machine telemetry | Presses, extruders, hydraulics, boiler, chiller, compressor, heat pump, HVAC, PV, BESS, energy and water meters | edge collectors | Build |
|
||||
| QC instrument integration | Optical inspection results and images, metrology CSV ingestion, PVC lab entries, audio QC scores, packaging scans | stations plus `edge-press` | Launch, Expand |
|
||||
| Station kiosks | Badge check-in and scanning at each manual step; kiosk browser on the factory application | `st-*` machines | Build |
|
||||
| Observability and alerting | Process alarms (Grafana on TimescaleDB), host alarms (clan monitoring), routing to phones, data-silence alarms | `core-1` | Build |
|
||||
| Backup and DR | ZFS snapshots, Borg to `backup-1` and off-site, PostgreSQL point-in-time recovery, restore drills | `backup-1`, `vps-1` | Build |
|
||||
| Identity | OIDC single sign-on for staff, badge IDs for operators at stations, role model for customers | `core-1` (Pocket ID) | Build |
|
||||
| Client audio vault | Encrypted, isolated storage for pre-release audio with checksums and access logging | `core-1` (separate dataset) | Build |
|
||||
| Site systems integration | Access-control door events, fire panel and BESS detection contacts, UPS state, CCTV | `edge-utility`, optional `nvr-1` | Build |
|
||||
| Off-site node | ZeroTier moon with a public IP, off-site backup target, public reverse proxy for the portal | `vps-1` | Build |
|
||||
| QC instrument integration | Optical inspection results and images, metrology CSV ingestion, PVC lab entries, audio QC scores, packaging scans | stations plus `vinyl-edge-press` | Launch, Expand |
|
||||
| Station kiosks | Badge check-in and scanning at each manual step; kiosk browser on the factory application | `vinyl-st-*` | Build |
|
||||
| Process alerting | Environment, utilities, reject rate, stamper life, PV/BESS, fire and BESS detection contacts, UPS, data silence; delivered to phones | `vinyl-core` (vmalert + Alertmanager) | Build |
|
||||
| Fleet monitoring | Host metrics, journals, host alerts for every plant machine | `control` (existing) | Build |
|
||||
| Backup and DR | ZFS snapshots and replication, Borg to the plant backup server and off site, PostgreSQL point-in-time recovery, restore drills | `vinyl-backup`, off-site destination | Build |
|
||||
| Identity | Staff sign-on (OIDC), badge IDs for operators at stations, customer role | `vinyl-core` | Build |
|
||||
| Client audio vault | Encrypted, isolated dataset for pre-release audio with checksums and access logging | `vinyl-core` | Build |
|
||||
| Site systems integration | Access-control door events, fire panel and BESS detection contacts, UPS state | `vinyl-edge-util` | Build |
|
||||
| Customer portal, public | TLS termination and forwarding over the mesh to the plant core | `web01` (existing) | Launch |
|
||||
| CCTV | Recording on its own VLAN | vendor NVR appliance, or `vinyl-nvr` (Frigate) if wanted | Build |
|
||||
|
||||
## Architecture
|
||||
|
||||
```mermaid
|
||||
flowchart LR
|
||||
subgraph L0[Field]
|
||||
subgraph L0[Field, isolated OT segments]
|
||||
PLC[Press and extruder PLCs<br/>OPC UA / S7]
|
||||
UT[Boiler, chiller, compressor,<br/>heat pump, HVAC<br/>Modbus / BACnet]
|
||||
EN[Energy meters, Deye inverters,<br/>BESS, water meters<br/>Modbus / pulse]
|
||||
ENV[Zone T / RH / PM / dP sensors<br/>Modbus RTU]
|
||||
GV[Rectifiers, bath sensors<br/>Modbus]
|
||||
VIS[Vision controller<br/>TCP results, FTP images]
|
||||
VIS[Vision controller<br/>TCP results, SFTP images]
|
||||
INST[Keyence, XRF, lab instruments<br/>CSV export]
|
||||
end
|
||||
subgraph L1[Edge, NixOS]
|
||||
EP[edge-press<br/>Telegraf + vision receiver]
|
||||
EU[edge-utility<br/>Telegraf]
|
||||
EG[edge-galvanics<br/>Telegraf]
|
||||
ST[st-* stations<br/>kiosk, scanners, ingestion]
|
||||
subgraph L1[Edge, NixOS, dual-homed]
|
||||
EP[vinyl-edge-press<br/>Telegraf + vision receiver]
|
||||
EU[vinyl-edge-util<br/>Telegraf + dry-contact I/O]
|
||||
EG[vinyl-edge-galv<br/>Telegraf]
|
||||
ST[vinyl-st-* stations<br/>kiosk, scanners, ingestion]
|
||||
end
|
||||
subgraph L2[Core, NixOS]
|
||||
MQ[MQTT broker]
|
||||
DB[(PostgreSQL + TimescaleDB)]
|
||||
OBJ[(Object storage)]
|
||||
subgraph L2[Plant core, NixOS, servers VLAN]
|
||||
MQ[Mosquitto]
|
||||
VM[(VictoriaMetrics<br/>vmalert, Grafana)]
|
||||
DB[(PostgreSQL)]
|
||||
APP[Factory application]
|
||||
GF[Grafana + alerting]
|
||||
AM[Alertmanager]
|
||||
end
|
||||
subgraph L3[Outside]
|
||||
VPS[vps-1: moon, backup, proxy]
|
||||
subgraph GW[gw-site-1]
|
||||
PX[Caddy internal proxy<br/>factory.site1.cnx.network]
|
||||
end
|
||||
subgraph L3[Fleet, Hetzner, over the mesh]
|
||||
CTL[control: node metrics,<br/>journals, host alerts]
|
||||
WEB[web01: public proxy]
|
||||
BK[off-site borg destination]
|
||||
CUST[Customer portal]
|
||||
PH[Phones: alerts]
|
||||
end
|
||||
@@ -117,146 +167,208 @@ flowchart LR
|
||||
EP --> MQ
|
||||
EU --> MQ
|
||||
EG --> MQ
|
||||
ST --> APP
|
||||
MQ --> DB
|
||||
MQ --> VM
|
||||
MQ --> APP
|
||||
APP --> DB
|
||||
APP --> OBJ
|
||||
EP --> OBJ
|
||||
DB --> GF
|
||||
GF --> PH
|
||||
APP --> VPS --> CUST
|
||||
ST --> PX --> APP
|
||||
VM --> AM --> PH
|
||||
APP -.mesh.-> WEB --> CUST
|
||||
L2 -.mesh.-> CTL
|
||||
L2 -.mesh.-> BK
|
||||
```
|
||||
|
||||
Three rules keep this simple: field devices talk only to their edge
|
||||
collector (they are on VLANs with no route anywhere else); edge collectors
|
||||
talk only to the broker and object storage; the application and Grafana
|
||||
talk only to the database, the broker and object storage. The VPS reaches
|
||||
the core over the ZeroTier mesh, never over an open port.
|
||||
Three rules keep this simple: field devices sit on isolated OT segments
|
||||
whose only other member is their edge collector; edge collectors publish to
|
||||
the core and nothing else; stations and office clients reach the
|
||||
application only through the gateway's proxy. Everything that leaves the
|
||||
site rides the ZeroTier mesh, never an open port.
|
||||
|
||||
## Machines
|
||||
|
||||
All NixOS, all in the clan inventory. Hardware classes are planning
|
||||
positions; models are chosen at purchase.
|
||||
All NixOS, all entries in the clan inventory. Names follow the fleet
|
||||
convention (`gw-<city>-<n>` for gateways, short role names for servers)
|
||||
with a `vinyl-` prefix so the plant's machines are recognisable in a
|
||||
multi-site inventory. `<site>` is the city code chosen at site selection;
|
||||
Mueang Chi is in Lamphun province, so `lpn` is the working assumption and
|
||||
the gateway is `gw-lpn-1`, giving internal names under `*.lpn1.cnx.network`.
|
||||
Hardware classes are planning positions; models are chosen at purchase.
|
||||
|
||||
| Machine | Role | Hardware class | Where | Clan tags |
|
||||
|---|---|---|---|---|
|
||||
| `router-1` | Firewall, VLANs, DHCP/DNS, NTP (chrony), dual WAN failover | fanless x86, 4+ NICs | IT room | `core` |
|
||||
| `core-1` | PostgreSQL + TimescaleDB, Mosquitto, Telegraf persister, factory app, Grafana, Garage object storage, Pocket ID, Caddy | 1U/2U server, ECC RAM 64 to 128 GB, mirrored NVMe for OS and database, HDD pool for objects, dual PSU on UPS | IT room | `core`, `db` |
|
||||
| `backup-1` | Borg server, PostgreSQL streaming replica, second Garage node, ZFS receive target | tower or 2U, large HDD pool | separate room from `core-1` (archive side of the building) | `core`, `backup` |
|
||||
| `vps-1` | ZeroTier moon (public IP), off-site Borg destination, third Garage node, reverse proxy for the customer portal | small cloud VPS with block storage, outside Thailand or in Bangkok, decision open | cloud | `offsite` |
|
||||
| `edge-press` | Telegraf (OPC UA / S7 to the presses and extruders, Modbus to hydraulics and label oven), vision result receiver, disk-backed buffer | fanless DIN-rail IPC, 2 LAN, 2 to 4 RS485 | press hall control cabinet | `edge` |
|
||||
| `edge-utility` | Telegraf (Modbus to boiler, chiller, compressor, heat pump, energy meters, inverters, BESS, water; BACnet or Modbus to the HVAC BMS), zone environment loops, dry-contact I/O for fire panel, BESS detection and UPS | same class, more RS485 | electrical room or utility yard cabinet | `edge` |
|
||||
| `edge-galvanics` | Telegraf (rectifiers, bath sensors, extraction status) | same class, corrosion-protected enclosure outside the wet area | galvanics service corridor | `edge` (Expand phase) |
|
||||
| `st-intake` | Office workstation for audio intake and gates (plain browser; not a kiosk) | any NixOS desktop | office | `station` |
|
||||
| `st-cutting` | Session log entry, lacquer registration, scribe ID | mini PC, touch screen, badge reader | cutting room | `station` |
|
||||
| `st-press-1`, `st-press-2` | Operator check-in, stamper mount/unmount scan, PVC lot and label lot scan, test pressing hold, reject reasons | mini PC, touch screen, badge reader, 2D scanner | at each press | `station` |
|
||||
| `st-lab` | PVC lot gate entry; reads instruments with serial export, manual entry otherwise; CoA attachment | mini PC, RS232/USB to instruments | material lab | `station` |
|
||||
| `st-metrology` | SMB share the Keyence and XRF PCs export into; ingestion watcher; part serial scan | mini PC | metrology bench (Expand phase) | `station` |
|
||||
| `st-audioqc` | Needle-drop capture and analysis pipeline | mini PC with audio interface, turntable, phono stage | listening/QC room (Expand phase) | `station` |
|
||||
| `st-pack-1` | Runout code camera read, jacket barcode scan, BOM check, barcode verifier | mini PC, camera, scanner, verifier | packaging | `station` |
|
||||
| `st-ship` | Consignment assembly, carrier label and tracking capture | mini PC, label printer | shipping | `station` |
|
||||
| `nvr-1` | Frigate CCTV recording on its own VLAN (optional; a vendor NVR appliance is the alternative) | small server with GPU or Coral accelerator | IT room | `cctv` |
|
||||
| Machine | Role | Hardware class | Where |
|
||||
|---|---|---|---|
|
||||
| `gw-lpn-1` | Site gateway: `cnx.router` with the plant VLANs, internal proxy for the factory application and Grafana, NTP for the site | Topton 1U N300, 4x 2.5G (fleet standard); a 10G SFP+ variant if the core server link warrants it | IT room |
|
||||
| `vinyl-core` | PostgreSQL, Mosquitto, Telegraf persister, VictoriaMetrics + vmalert + Grafana, Alertmanager, factory application, ZFS datasets for files (audio captures, inspection images, metrology raw data, CoA scans, client audio) | 1U/2U server, ECC RAM 64 to 128 GB, mirrored NVMe for OS and database, HDD mirror or raidz for files, dual PSU on UPS | IT room |
|
||||
| `vinyl-backup` | Borg server for the plant clients, ZFS receive target for `vinyl-core`'s datasets, PostgreSQL streaming replica, pgBackRest repository | tower or 2U, large HDD pool | separate room from `vinyl-core` (archive side of the building) |
|
||||
| `vinyl-edge-press` | Telegraf (OPC UA / S7 to presses and extruders, Modbus to hydraulics and label oven), vision result receiver, SFTP target for inspection images, chrony serving the OT segment, disk-backed MQTT buffer | fanless DIN-rail IPC, 2 LAN, 2 to 4 RS485 | press hall control cabinet |
|
||||
| `vinyl-edge-util` | Telegraf (Modbus to boiler, chiller, compressor, heat pump, energy meters, inverters, BESS; BACnet or Modbus to the HVAC BMS), zone environment loops, dry-contact I/O for fire panel, BESS detection and UPS | same class, more RS485 | electrical room or utility yard cabinet |
|
||||
| `vinyl-edge-galv` | Telegraf (rectifiers, bath sensors, extraction status) | same class, corrosion-protected enclosure outside the wet area | galvanics service corridor (Expand phase) |
|
||||
| `vinyl-st-cutting` | Session log entry, lacquer registration, scribe ID | mini PC, touch screen, badge reader | cutting room |
|
||||
| `vinyl-st-press1`, `vinyl-st-press2` | Operator check-in, stamper mount/unmount scan, PVC lot and label lot scan, test pressing hold, reject reasons | mini PC, touch screen, badge reader, 2D scanner | at each press |
|
||||
| `vinyl-st-lab` | PVC lot gate entry; reads instruments with serial export, manual entry otherwise; CoA attachment | mini PC, RS232/USB to instruments | material lab |
|
||||
| `vinyl-st-metrology` | SMB share the Keyence and XRF PCs export into; ingestion watcher; part serial scan | mini PC | metrology bench (Expand phase) |
|
||||
| `vinyl-st-audioqc` | Needle-drop capture and analysis pipeline | mini PC with audio interface, turntable, phono stage | listening/QC room (Expand phase) |
|
||||
| `vinyl-st-pack1` | Runout code camera read, jacket barcode scan, BOM check, barcode verifier | mini PC, camera, scanner, verifier | packaging |
|
||||
| `vinyl-st-ship` | Consignment assembly, carrier label and tracking capture | mini PC, label printer | shipping |
|
||||
| `vinyl-nvr` | Frigate CCTV recording on the cctv VLAN (optional; a vendor NVR appliance is the alternative) | small server with GPU or Coral accelerator | IT room |
|
||||
|
||||
Stations run a kiosk browser (`cage` plus Firefox or Chromium) pointed at
|
||||
the factory application; badge readers and scanners are USB HID keyboard
|
||||
devices, so there is no driver work. Fifteen machines at launch, about
|
||||
twenty at maturity; every one is a few lines in the inventory.
|
||||
Office audio intake and gate approvals happen from ordinary staff laptops
|
||||
on the `lan` VLAN through the same proxy; no dedicated machine. Stations
|
||||
run a kiosk browser (`cage` plus Firefox or Chromium) pointed at the
|
||||
application; badge readers and scanners are USB HID keyboard devices, so
|
||||
there is no driver work. Fifteen plant machines at launch, about twenty at
|
||||
maturity; every one is a directory and a line in the inventory.
|
||||
|
||||
## Networks
|
||||
|
||||
| VLAN | Members | Rule |
|
||||
|---|---|---|
|
||||
| `ot-press` | press and extruder PLCs and HMIs, vision controller, `edge-press` | no internet, no route to other VLANs; `edge-press` is the only gateway |
|
||||
| `ot-utility` | boiler, chiller, compressor, heat pump, HVAC BMS, meters, inverters, BESS BMS, `edge-utility` | same |
|
||||
| `ot-galvanics` | rectifiers, bath transmitters, `edge-galvanics` | same |
|
||||
| `sensors` | RS485 loops terminate on the edge collectors, so zone sensors have no IP presence; any IP sensor that is added lives here | no internet |
|
||||
| `servers` | `core-1`, `backup-1`, `router-1` management | reachable from `stations`, `office`, edge collectors and the mesh |
|
||||
| `stations` | `st-*` kiosks, instrument PCs (Keyence, vision setup laptop) | reach `core-1` only |
|
||||
| `office` | staff laptops, printers | internet, `core-1` |
|
||||
| `cctv` | cameras, `nvr-1` | no internet; NVR reachable from `office` by role |
|
||||
| `guest` | visitors, vendor laptops | internet only |
|
||||
| `mgmt` | switch and IPMI management interfaces | `router-1` and `core-1` admins only |
|
||||
The plant is site `<siteId>` (next free number in the fleet's site table;
|
||||
`cnx` is 1 and the public-WiFi site is 2, so 3 is the working assumption)
|
||||
and owns `10.<siteId>.0.0/16`. VLANs follow the fleet convention; the
|
||||
ids above 40 are proposals.
|
||||
|
||||
Vendor remote support (Newbilt and Pheenix both offer remote monitoring) goes
|
||||
through a jump account on `router-1` over the ZeroTier mesh, time-boxed and
|
||||
logged, with a port forward to the one PLC HMI they need. No machine ever
|
||||
gets a vendor's own cellular router or cloud agent on the OT VLAN.
|
||||
| VLAN | id | Members | `allowWan` | Rule |
|
||||
|---|---|---|---|---|
|
||||
| `mgmt` | 10 | switches, APs, Omada, IPMI, admin laptops on site | yes | fleet convention: trusted, reaches everything |
|
||||
| `lan` | 20 | office laptops, printers | yes | proxy to factory app and Grafana, internet |
|
||||
| `guest` | 30 | visitors, vendor laptops | yes | internet only |
|
||||
| `servers` | 100 | `vinyl-core`, `vinyl-backup`, the servers-side NIC of every edge collector | yes (mesh, nix, journald, off-site backup) | no inbound from other VLANs; the gateway's own Caddy dials the app here |
|
||||
| `stations` | 110 | `vinyl-st-*`, instrument PCs (Keyence, vision setup laptop), label printer | yes (mesh, deploys, journald) | proxy to the factory app only; `dhcp.reservations` for every station |
|
||||
| `cctv` | 120 | cameras, NVR | no | reachable from `mgmt`; NVR UI via the proxy if wanted |
|
||||
| `ot-press` | 210 | press and extruder PLCs and HMIs, vision controller, OT NIC of `vinyl-edge-press` | no | isolated segment, see below |
|
||||
| `ot-util` | 220 | boiler, chiller, compressor, heat pump, HVAC BMS, meters, inverters, BESS BMS, OT NIC of `vinyl-edge-util` | no | isolated segment |
|
||||
| `ot-galv` | 230 | rectifiers, bath transmitters, OT NIC of `vinyl-edge-galv` | no | isolated segment |
|
||||
|
||||
Dual WAN: fibre plus a 4G/5G modem on `router-1`, failover only. The plant
|
||||
does not depend on the internet to run: everything in the tables above is
|
||||
on site except `vps-1`, and the only things that stop when the internet
|
||||
drops are the customer portal and off-site backup.
|
||||
**OT segments are islands, not routes.** Each edge collector is dual-homed:
|
||||
one NIC on `servers` (an access port on the cabinet switch), one NIC on
|
||||
its OT segment. The OT segment lives on the cabinet's industrial switch;
|
||||
if it must span cabinets it rides the building trunk as a VLAN with
|
||||
`dhcp.enable = false` and `allowWan = false`, and the router's default
|
||||
no-inter-VLAN policy keeps it closed. Either way the gateway forwards
|
||||
nothing into or out of an OT segment; the collector is the only bridge,
|
||||
and it only publishes. Zone sensors on RS485 loops terminate directly on
|
||||
the collectors and have no IP presence at all. Cheap ESP32/MQTT sensor
|
||||
nodes are acceptable for extra density in non-critical zones (on
|
||||
`stations`, publishing to the core), never for alarmed zones.
|
||||
|
||||
## Clan inventory (sketch)
|
||||
**Stations never route to `servers`.** They reach
|
||||
`https://factory.lpn1.cnx.network`, which Blocky resolves to the gateway
|
||||
and Caddy forwards to `vinyl-core` on the servers VLAN, with the real
|
||||
wildcard certificate the router module already issues. `proxy.allowVlans`
|
||||
gains `stations`. The same proxy serves `grafana.lpn1.cnx.network` to the
|
||||
office. This keeps the fleet's trust model intact: no VLAN talks to
|
||||
another VLAN; the router talks to its backends.
|
||||
|
||||
The plant clan in outline. Option names follow the clan release current at
|
||||
writing (26.05); check them against the pinned release before use, and
|
||||
expect the monitoring service to change, since it is still marked
|
||||
experimental upstream.
|
||||
Router module extensions the plant needs (small, and useful for the other
|
||||
sites too):
|
||||
|
||||
```nix
|
||||
{
|
||||
meta.name = "cnx-vinyl";
|
||||
meta.domain = "cnx"; # mesh-only TLD; hosts resolve as <name>.cnx
|
||||
1. **NTP served by the gateway** to every VLAN (chrony `allow` for the
|
||||
site's `/16`, UDP 123 in the per-VLAN firewall set) so stations and
|
||||
the NVR sync locally; today the gateway is only a chrony client.
|
||||
2. **Static-only VLANs**: a `dhcp.enable = false` VLAN should still
|
||||
accept `reservations` semantics for documentation, or simply be
|
||||
documented as address-by-hand; either is fine, decide when writing it.
|
||||
3. **Second WAN**: a 4G/5G modem as failover for the PPPoE session
|
||||
(`wan.backupInterface` with a metric and a health check). Not needed
|
||||
for launch because the plant runs without the internet; needed before
|
||||
the customer portal is promised as always-on.
|
||||
|
||||
inventory.machines = {
|
||||
router-1 = { tags = [ "core" ]; };
|
||||
core-1 = { tags = [ "core" "db" "monitoring-server" ]; };
|
||||
backup-1 = { tags = [ "core" "backup" ]; };
|
||||
vps-1 = { tags = [ "offsite" ]; };
|
||||
edge-press = { tags = [ "edge" ]; };
|
||||
edge-utility = { tags = [ "edge" ]; };
|
||||
edge-galvanics = { tags = [ "edge" ]; };
|
||||
st-cutting = { tags = [ "station" ]; };
|
||||
st-press-1 = { tags = [ "station" ]; };
|
||||
st-lab = { tags = [ "station" ]; };
|
||||
st-pack-1 = { tags = [ "station" ]; };
|
||||
st-ship = { tags = [ "station" ]; };
|
||||
};
|
||||
Vendor remote support (Newbilt and Pheenix both offer remote monitoring)
|
||||
goes through an admin's SSH port-forward across the mesh into the relevant
|
||||
edge collector and from there to the one PLC HMI they need, time-boxed and
|
||||
logged. No machine ever gets a vendor's own cellular router or cloud agent
|
||||
on an OT segment.
|
||||
|
||||
inventory.instances = {
|
||||
sshd.roles.server.tags.all = { };
|
||||
admin.roles.default.tags.all = { }; # admin users and keys
|
||||
## What changes in the clan repo
|
||||
|
||||
zerotier = {
|
||||
roles.controller.machines.core-1 = { };
|
||||
roles.moon.machines.vps-1.settings.stableEndpoints = [ "<public-ip>/9993" ];
|
||||
roles.peer.tags.all = { };
|
||||
Following the "Adding a site" procedure in the clan runbook, plus the
|
||||
plant's own modules. Everything below is one pull request per machine
|
||||
class, in this order.
|
||||
|
||||
```
|
||||
clan.nix
|
||||
fleet: + gw-lpn-1, vinyl-core, vinyl-backup, vinyl-edge-press,
|
||||
vinyl-edge-util, vinyl-st-press1, vinyl-st-lab,
|
||||
vinyl-st-pack1, vinyl-st-ship (then the rest as they come)
|
||||
borgbackup:
|
||||
roles.server.machines.vinyl-backup = { };
|
||||
roles.client.machines.vinyl-core.settings.destinations = {
|
||||
plant = { repo = "borg@vinyl-backup:vinyl-core"; };
|
||||
offsite = { repo = "<storage-box or bk host>:vinyl-core"; };
|
||||
};
|
||||
roles.client.machines.vinyl-edge-press = { ... plant only ... };
|
||||
# side benefit: control can now back up its VictoriaMetrics TSDB to
|
||||
# vinyl-backup, closing the open item in the clan TODO
|
||||
(no `internet` entries: plant machines sit behind PPPoE like gw-cnx-1
|
||||
and are reached over the mesh)
|
||||
|
||||
borgbackup = {
|
||||
roles.server.machines.backup-1 = { };
|
||||
roles.server.machines.vps-1 = { };
|
||||
roles.client.tags.core = { };
|
||||
roles.client.tags.edge = { };
|
||||
};
|
||||
modules/mesh-hosts.nix + every plant machine in the name list
|
||||
modules/monitoring/server.nix
|
||||
+ node_exporter targets for every plant machine
|
||||
+ a second Grafana datasource "vinyl-vm" pointing
|
||||
at [vinyl-core mesh]:8428 so fleet dashboards
|
||||
can show plant series
|
||||
modules/monitoring/alerts.nix
|
||||
unchanged; host rules already cover new targets
|
||||
machines/ns1/configuration.nix
|
||||
+ dns-acme-gw-lpn-1-knot generator, keyFiles entry,
|
||||
acl_acme_gw_lpn_1 scoped to _acme-challenge.lpn1
|
||||
(copy the gw-cnx-1 blocks)
|
||||
modules/dns/acme-gw-secret.nix
|
||||
reused as-is with "gw-lpn-1"
|
||||
modules/web-proxy.nix + virtualHosts."portal.<domain>" -> [vinyl-core mesh]:8080
|
||||
(second cert + scoped TSIG key if <domain> is
|
||||
not cnx.network, following the acme_web01 pattern)
|
||||
|
||||
monitoring = {
|
||||
roles.server.machines.core-1.settings.grafana.enable = true;
|
||||
roles.client.tags.all = { };
|
||||
};
|
||||
};
|
||||
machines/gw-lpn-1/ copy of gw-cnx-1: site "lpn", siteId 3, the VLAN
|
||||
table above, proxy.services.factory and .grafana,
|
||||
proxy.allowVlans = [ "mgmt" "lan" "stations" ]
|
||||
machines/vinyl-core/ imports modules/vinyl/{core,metrics,factory-app,
|
||||
alertmanager}.nix + monitoring/exporters.nix
|
||||
machines/vinyl-backup/ imports modules/vinyl/backup.nix + exporters.nix
|
||||
machines/vinyl-edge-*/ imports modules/vinyl/edge.nix with the cabinet's
|
||||
Telegraf inputs and the OT NIC config
|
||||
machines/vinyl-st-*/ imports modules/vinyl/station.nix with the kiosk URL
|
||||
|
||||
# Our own NixOS modules, applied by tag or by machine:
|
||||
# modules/edge-collector.nix Telegraf with the tag lists for that cabinet,
|
||||
# Mosquitto bridge with disk buffer
|
||||
# modules/core-data.nix PostgreSQL + TimescaleDB, Mosquitto, Telegraf
|
||||
# persister, Garage, Grafana, pgBackRest
|
||||
# modules/factory-app.nix the application service and its migrations
|
||||
# modules/station-kiosk.nix cage + browser, HID readers, auto-login
|
||||
# modules/router.nix nftables zoning, VLAN interfaces, chrony,
|
||||
# dual-WAN failover
|
||||
}
|
||||
modules/vinyl/core.nix PostgreSQL (ZFS dataset, pg_hba for the app and
|
||||
the replica), Mosquitto (per-client passwords from
|
||||
vars generators), Telegraf persister (MQTT in,
|
||||
VictoriaMetrics out), ZFS datasets and sanoid
|
||||
modules/vinyl/metrics.nix VictoriaMetrics + vmalert + Grafana for the plant,
|
||||
a sibling of monitoring/server.nix with the
|
||||
process rules and dashboards under
|
||||
modules/vinyl/dashboards/
|
||||
modules/vinyl/alertmanager.nix
|
||||
receivers: Telegram or LINE for the shift group,
|
||||
SMS gateway for the critical set, email digest;
|
||||
tokens from vars generators
|
||||
modules/vinyl/factory-app.nix
|
||||
the cnx-factory package as a flake input (like
|
||||
nixos-mailserver is today), systemd service,
|
||||
migrations on start, DB password from vars,
|
||||
OIDC client secret from vars
|
||||
modules/vinyl/edge.nix Telegraf with per-machine input lists, MQTT output
|
||||
with disk buffer, chrony `allow` on the OT NIC,
|
||||
networkd config for the two NICs, SFTP chroot for
|
||||
vision images (press collector only)
|
||||
modules/vinyl/station.nix cage + browser kiosk, auto-login, HID readers,
|
||||
SMB share and ingestion watcher where needed
|
||||
modules/vinyl/backup.nix borg server role settings, syncoid receive,
|
||||
PostgreSQL replica, pgBackRest repo
|
||||
modules/router/… the three extensions above
|
||||
docs/src/vinyl.md the plant chapter of the runbook, + SUMMARY.md
|
||||
```
|
||||
|
||||
What clan provides out of the box and we do not write ourselves: SSH and
|
||||
admin user management, the ZeroTier mesh (controller on `core-1`, the VPS
|
||||
as a publicly reachable moon so the plant and remote consultants find each
|
||||
other behind NAT), Borg backups with generated keys, host metrics and
|
||||
journal shipping with Grafana on the server role, and sops-encrypted
|
||||
secrets per machine. What we write: the five modules listed in the sketch
|
||||
and the factory application itself.
|
||||
Operational notes that already bit the fleet and apply here: `git add` a
|
||||
new `machines/` directory before evaluating (untracked files are invisible
|
||||
to the flake); run `clan vars generate <machine>` (YubiKey) before the
|
||||
first install and again after adding a generator; check `facter.json` for
|
||||
the real NIC names after install; the `clan` wrapper in the dev shell
|
||||
updates machines sequentially so YubiKey prompts are not buried.
|
||||
|
||||
Repository layout, decided: infrastructure lives in `cnx-network-clan`;
|
||||
the factory application gets its own repository `cnx-factory` in the B4L
|
||||
organisation and is consumed as a flake input; this repository stays
|
||||
documents and links to both. That satisfies the README's promise that the
|
||||
project repository "hosts the software" without mixing Nix, Rust and
|
||||
planning prose in one history.
|
||||
|
||||
## Data acquisition, source by source
|
||||
|
||||
@@ -268,12 +380,12 @@ is bought, not retrofitted. Rates are planning values.
|
||||
|
||||
| Source | Signals | Interface | Rate | Requirement to write into the RFQ |
|
||||
|---|---|---|---|---|
|
||||
| Newbilt Classic 12" automatic (Siemens PLC, vendor states SCADA/OPC UA) | cycle counter, machine state, cycle time, mold top/bottom temperatures, steam valve state, press pressure and force, extruder zone temperatures, screw speed, melt temperature and pressure, cake weight if measured, label feed state, alarm codes | OPC UA server on the PLC, read by Telegraf `inputs.opcua` | per cycle plus 1 Hz | OPC UA server licensed and enabled, full node list with units delivered with the machine, cycle counter exposed as a node, read access for our collector, no cloud agent required for warranty |
|
||||
| Newbilt Classic 12" automatic (Siemens PLC, vendor states SCADA/OPC UA) | cycle counter, machine state, cycle time, mold top/bottom temperatures, steam valve state, press pressure and force, extruder zone temperatures, screw speed, melt temperature and pressure, cake weight if measured, label feed state, alarm codes | OPC UA server on the PLC, read by Telegraf `inputs.opcua` | per cycle plus 1 Hz | OPC UA server licensed and enabled, full node list with units delivered with the machine, cycle counter exposed as a node, read access for our collector, no cloud agent required for warranty, PLC clock accepting NTP |
|
||||
| Newbilt HRP 12 semi-automatic and VEX 50 extruder (PLC type unconfirmed) | as above where the PLC has them; on a relay-logic machine at least press closed/open, steam on/off, cycle count | OPC UA or Siemens S7 (`inputs.s7comm`); fallback: our own 4 to 20 mA sensors on a Modbus TCP I/O module and a cycle count from the mold-closed limit switch | per cycle plus 1 Hz | state what the PLC is and which of the two paths applies; the fallback sensor set is priced separately |
|
||||
| Pheenix AD12 (Beckhoff PLC, remote monitoring supported) | same tag family as the Classic | OPC UA (Beckhoff TF6100) or ADS; `inputs.opcua` | per cycle plus 1 Hz | OPC UA license included, tag list delivered, remote monitoring routed through our jump host |
|
||||
| Pheenix AD12 (Beckhoff PLC, remote monitoring supported) | same tag family as the Classic | OPC UA (Beckhoff TF6100) or ADS; `inputs.opcua` | per cycle plus 1 Hz | OPC UA license included, tag list delivered, remote monitoring routed through our mesh, not the vendor's |
|
||||
| Hydraulic aggregate | system pressure, oil temperature, tank level, filter differential pressure | via the press PLC if exposed, else own transmitters on the I/O module | 1 Hz | ask whether the aggregate's sensors are on the PLC |
|
||||
| Label dry oven | chamber temperature, timer state | Modbus if the controller has it, else a thermocouple on the I/O module | 1/min | |
|
||||
| PVC grinder and regrind scale | run state, batch weight | scale with RS232 to `st-press`, run contact to I/O | per batch | scale must have a serial output |
|
||||
| PVC grinder and regrind scale | run state, batch weight | scale with RS232 to `vinyl-st-press1`, run contact to I/O | per batch | scale must have a serial output |
|
||||
|
||||
### Utilities and energy
|
||||
|
||||
@@ -305,10 +417,9 @@ is bought, not retrofitted. Rates are planning values.
|
||||
|
||||
Industrial RS485 Modbus RTU transmitters on wired loops to the nearest edge
|
||||
collector, one reading per minute, with a reference-grade PM instrument in
|
||||
the archive or cutting room to check the cheaper sensors against. Cheap
|
||||
ESP32/MQTT sensor nodes are acceptable for extra density in non-critical
|
||||
zones, never for the alarmed ones. Every zone alarm has two thresholds
|
||||
(warning, action) and a rate-of-change alarm for the archive.
|
||||
the archive or cutting room to check the cheaper sensors against. Every
|
||||
zone alarm has two thresholds (warning, action) and a rate-of-change alarm
|
||||
for the archive.
|
||||
|
||||
### Galvanics (Expand phase)
|
||||
|
||||
@@ -324,9 +435,9 @@ results are entered at a station against the bath ID.
|
||||
Access-control door events (badge ID, door, direction, time) from the
|
||||
controller's API or export; fire alarm panel zone and fault contacts, BESS
|
||||
off-gas and early-smoke detection, UPS on-battery and low-battery (NUT on
|
||||
`core-1` talking to the UPS) as dry contacts on `edge-utility`. CCTV stays
|
||||
on its own VLAN with its own retention; it is never joined to production
|
||||
data.
|
||||
`vinyl-core` talking to the UPS) as dry contacts on `vinyl-edge-util`.
|
||||
CCTV stays on its own VLAN with its own retention; it is never joined to
|
||||
production data.
|
||||
|
||||
### What produces no telemetry
|
||||
|
||||
@@ -340,21 +451,22 @@ logged by the sensors above.
|
||||
|
||||
| Instrument | How results reach the database | Key | Open integration item |
|
||||
|---|---|---|---|
|
||||
| Inline optical inspection at the press unloader (Keyence or Cognex class, custom integration) | vision controller sends one result string per record over TCP to a receiver on `edge-press`; images pushed by FTP/SFTP to object storage | press ID + cycle counter, passed from the PLC to the vision trigger | the cycle counter hand-off between PLC and vision controller is an integrator deliverable and an acceptance test |
|
||||
| Stamper metrology (Keyence VK-X, VR-6000, XRF gauge, profilometer) | vendor Windows PCs export CSV and raw 3D to an SMB share on `st-metrology`; a watcher parses and posts | back-side Data Matrix serial, scanned at the bench before measurement | export format per instrument confirmed with Keyence Thailand |
|
||||
| PVC material lab (moisture analyzer, spectrophotometer, balance, later torque rheometer, DSC, FTIR) | instruments with RS232/USB export are read at `st-lab`; the rest are typed in with the printout photographed; CoA PDF attached | compound lot ID (printed label scanned at intake) | which benchtop models have serial export |
|
||||
| Audio QC station | capture service on `st-audioqc` records the needle-drop (PipeWire, FLAC to object storage); analysis pipeline computes spectral-envelope match to the source master, click/pop count, noise floor, channel balance; scores posted | record key (stamper + press + cycle + side), typed or picked from the run list | first-of-kind pipeline, developed in Expand phase against launch-phase recordings |
|
||||
| Inline optical inspection at the press unloader (Keyence or Cognex class, custom integration) | vision controller sends one result string per record over TCP to a receiver on `vinyl-edge-press`; images pushed by SFTP to the collector, synced to the core's image dataset | press ID + cycle counter, passed from the PLC to the vision trigger | the cycle counter hand-off between PLC and vision controller is an integrator deliverable and an acceptance test |
|
||||
| Stamper metrology (Keyence VK-X, VR-6000, XRF gauge, profilometer) | vendor Windows PCs export CSV and raw 3D to an SMB share on `vinyl-st-metrology`; a watcher parses and posts | back-side Data Matrix serial, scanned at the bench before measurement | export format per instrument confirmed with Keyence Thailand |
|
||||
| PVC material lab (moisture analyzer, spectrophotometer, balance, later torque rheometer, DSC, FTIR) | instruments with RS232/USB export are read at `vinyl-st-lab`; the rest are typed in with the printout photographed; CoA PDF attached | compound lot ID (printed label scanned at intake) | which benchtop models have serial export |
|
||||
| Audio QC station | capture service on `vinyl-st-audioqc` records the needle-drop (PipeWire, FLAC to the core's capture dataset); analysis pipeline computes spectral-envelope match to the source master, click/pop count, noise floor, channel balance; scores posted | record key (stamper + press + cycle + side), typed or picked from the run list | first-of-kind pipeline, developed in Expand phase against launch-phase recordings |
|
||||
| Packaging assembly check | camera with darkfield lighting reads the scribed dead-wax code (a handheld scanner will not read a scribed code on black vinyl reliably); handheld scanner reads the jacket barcode; barcode verifier grades it | order + record key | confirm dead-wax code readability with a sample before the packaging station is designed |
|
||||
| Label print inspection | same vision family as the record label check; result per label lot | label lot ID | shared with the record inspection budget |
|
||||
|
||||
## The factory application
|
||||
|
||||
Working name `cnx-factory`. Server-rendered web application in Rust (axum,
|
||||
SQLx, minijinja templates, HTMX) on PostgreSQL, the stack B4L already uses
|
||||
for its other in-house tooling, with the same append-only ledger and
|
||||
hash-chained audit log pattern. It subscribes to the MQTT event topics
|
||||
(cycle complete, machine alarm, instrument result) and owns every write to
|
||||
the identity tables; Telegraf owns the writes to the time-series tables.
|
||||
Working name `cnx-factory`, its own repository. Server-rendered web
|
||||
application in Rust (axum, SQLx, minijinja templates, HTMX) on PostgreSQL,
|
||||
the stack B4L already uses for its other in-house tooling, with the same
|
||||
append-only ledger and hash-chained audit log pattern. It subscribes to
|
||||
the MQTT event topics (cycle complete, machine alarm, instrument result)
|
||||
and owns every write to the identity tables; Telegraf owns the writes to
|
||||
VictoriaMetrics. Packaged as a flake so the clan repo pins it as an input.
|
||||
|
||||
Modules, in build order:
|
||||
|
||||
@@ -377,8 +489,9 @@ Modules, in build order:
|
||||
lots with incoming QC.
|
||||
7. **Press runs and cycles**: a run binds order, stamper pair, press,
|
||||
operator, shift, PVC lot in the hopper, regrind batch, label lot; each
|
||||
cycle event from the PLC becomes a row keyed by press + counter; the
|
||||
record key is derived from it per side.
|
||||
cycle event from the PLC becomes a row keyed by press + counter with
|
||||
the key press values and the zone environment snapshot; the record key
|
||||
is derived from it per side.
|
||||
8. **QC verdicts**: optical per record, audio per sampled record, lab per
|
||||
lot, packaging per unit; reject reasons; test-pressing hold state.
|
||||
9. **Finishing, packaging, fulfillment**: assembly checks, consignment
|
||||
@@ -388,16 +501,15 @@ Modules, in build order:
|
||||
one customer sees only its own orders; PDF export of the trace.
|
||||
11. **Reports and signals**: yield per stamper, reject rate drift, audio
|
||||
score trend versus play count (the automatic retirement signal),
|
||||
energy per record, environment excursions overlaid on runs.
|
||||
energy per record, environment excursions overlaid on runs (the
|
||||
curves fetched from VictoriaMetrics for the run's window).
|
||||
|
||||
Core entities: `customer`, `order`, `release`, `side`, `audio_asset`,
|
||||
`gate_approval`, `session`, `lacquer`, `father`, `mother`, `stamper`,
|
||||
`stamper_measurement`, `press`, `press_run`, `press_cycle`, `record`,
|
||||
`optical_result`, `audio_result`, `pvc_lot`, `regrind_batch`, `label_lot`,
|
||||
`carton_lot`, `lab_result`, `packaging_check`, `shipment`, `operator`,
|
||||
`shift`, `event` (the hash chain). Time-series hypertables: `telemetry`
|
||||
(machine, tag, value), `environment` (zone, metric, value), `energy`
|
||||
(meter, kWh, kW), `water`.
|
||||
`shift`, `event` (the hash chain).
|
||||
|
||||
Stations use the same application in kiosk mode: an operator taps a badge
|
||||
(the same card the access-control system issues, so one ID) and scans
|
||||
@@ -405,55 +517,64 @@ whatever the step asks for. No forms longer than one screen.
|
||||
|
||||
## Observability and alerting
|
||||
|
||||
Two tiers, one Grafana:
|
||||
Two tiers, split by where the data is:
|
||||
|
||||
- **Process alarms** from TimescaleDB: zone environment excursions and
|
||||
rate of change, boiler pressure and level, chiller return temperature,
|
||||
compressed-air pressure, hydraulic pressure, reject rate per run above
|
||||
baseline, stamper approaching its play-count limit, PV or BESS faults,
|
||||
fire and BESS detection contacts, UPS on battery.
|
||||
- **Infrastructure alarms** from the clan monitoring stack: host down,
|
||||
disk, service failed, backup missed, certificate expiry.
|
||||
- **Process, on site** (`vinyl-core`: VictoriaMetrics, vmalert,
|
||||
Grafana, Alertmanager): zone environment excursions and rate of change,
|
||||
boiler pressure and level, chiller return temperature, compressed-air
|
||||
pressure, hydraulic pressure, reject rate per run above baseline,
|
||||
stamper approaching its play-count limit, PV or BESS faults, fire and
|
||||
BESS detection contacts, UPS on battery. Works with the WAN down.
|
||||
- **Hosts, on the fleet** (`control`): node_exporter and journald from
|
||||
every plant machine over the mesh, the existing `ScrapeTargetDown`,
|
||||
`RootFilesystemFull`, `BackupJobFailed`, `BackupStale` rules apply to
|
||||
them without changes.
|
||||
- **Data-silence alarms** in both tiers: a collector that has published
|
||||
nothing for five minutes is an alarm, whatever the last value was.
|
||||
|
||||
Routing: Telegram or the LINE Messaging API for the shift group, email for
|
||||
the daily digest, SMS through a Thai gateway for the critical set (boiler,
|
||||
fire, BESS, archive climate) with an on-call rota. The animated
|
||||
Routing: Telegram or the LINE Messaging API for the shift group, email
|
||||
digest daily, SMS through a Thai gateway for the critical set (boiler,
|
||||
fire, BESS, archive climate) with an on-call rota. `control`'s vmalert can
|
||||
drop `notifier.blackhole` and point at the same Alertmanager over the
|
||||
mesh, which closes the fleet's own alert-delivery item. The animated
|
||||
[plant operation page](plant-operation.html) is the design target for the
|
||||
live overview: once the telemetry tables exist it is fed from Grafana or
|
||||
directly from the database instead of its simulation.
|
||||
live overview: once the series exist it is fed from VictoriaMetrics
|
||||
instead of its simulation.
|
||||
|
||||
## Backup, retention and recovery
|
||||
|
||||
- **Hourly ZFS snapshots** on `core-1` (sanoid), replicated to `backup-1`
|
||||
(syncoid).
|
||||
- **Nightly Borg** from every `core` and `edge` machine to `backup-1` and
|
||||
to `vps-1` (clan borgbackup, two destinations).
|
||||
- **Hourly ZFS snapshots** on `vinyl-core` (sanoid), replicated to
|
||||
`vinyl-backup` (syncoid) for the file datasets and the PostgreSQL data
|
||||
directory.
|
||||
- **Nightly Borg** (clan `borgbackup`) from `vinyl-core` and the edge
|
||||
collectors to `vinyl-backup`, and from `vinyl-core` to the off-site
|
||||
destination as a second entry in `destinations`; repokey encryption as
|
||||
the fleet already does.
|
||||
- **PostgreSQL point-in-time recovery**: pgBackRest with WAL archiving to
|
||||
object storage, replicated to the off-site node; a streaming replica on
|
||||
`backup-1` for fast failover.
|
||||
- **Object storage** (Garage) with three nodes: `core-1`, `backup-1`,
|
||||
`vps-1`; audio captures, inspection images, metrology raw data and CoA
|
||||
scans survive the loss of any one node.
|
||||
- **Configuration**: the clan repo in Gitea, mirrored off-site; any machine
|
||||
is rebuilt from it.
|
||||
`vinyl-backup`, its repository included in the off-site Borg set; a
|
||||
streaming replica on `vinyl-backup` for fast failover.
|
||||
- **VictoriaMetrics**: `vmbackup` snapshots to `vinyl-backup` nightly; the
|
||||
fleet's own open item (backing up `control`'s TSDB) gets a destination
|
||||
at the same time.
|
||||
- **Configuration**: the clan repo and `cnx-factory` in Gitea; any machine
|
||||
is rebuilt from them.
|
||||
- **Restore drill quarterly**: restore the database to a scratch VM and
|
||||
open a random order's trace in the portal. A backup that has never been
|
||||
restored does not count.
|
||||
restored does not count. The `BackupStale` rule already watches the
|
||||
timers.
|
||||
|
||||
| Data | Retention |
|
||||
|---|---|
|
||||
| genealogy, orders, gates, QC verdicts, event log | life of the customer relationship, never deleted while the metal parts exist |
|
||||
| per-cycle press data | forever (small) |
|
||||
| 1 Hz machine telemetry | raw 2 years, then 1-minute aggregates forever |
|
||||
| zone environment | raw 5 years |
|
||||
| energy and water | forever (small) |
|
||||
| per-cycle press rows | forever (small) |
|
||||
| 1 Hz machine telemetry | 2 years in VictoriaMetrics (`retentionPeriod`); per-cycle rows carry the summary forever |
|
||||
| zone environment | 5 years (separate VM retention filter, or a second small instance) |
|
||||
| energy and water | forever (small; also summarised per shift into PostgreSQL) |
|
||||
| audio captures and inspection images | 2 years, longer for any record with a complaint |
|
||||
| client audio | per contract; default deleted 12 months after final delivery, or on request |
|
||||
| access-control events | 1 year |
|
||||
| CCTV | 30 days |
|
||||
| host logs and metrics | 90 days |
|
||||
| host logs and metrics | fleet defaults: 30 d logs, 180 d metrics on `control` |
|
||||
|
||||
PDPA applies to badge events, CCTV and customer contact data: a written
|
||||
retention policy, role-based access, and export/deletion on request. The
|
||||
@@ -461,18 +582,24 @@ customer portal shows operator roles, never operator names.
|
||||
|
||||
## Security
|
||||
|
||||
- OT VLANs have no internet and no inbound routes; edge collectors are the
|
||||
only bridge and they only publish.
|
||||
- Staff sign-on through Pocket ID (OIDC, passkeys) with roles: admin,
|
||||
engineer, operator, sales, customer. Stations authenticate by badge for
|
||||
attribution, not for privilege.
|
||||
- Secrets only in clan vars; nothing in plain text in the repo.
|
||||
- OT segments have no gateway interface and no internet; edge collectors
|
||||
are the only bridge and they only publish.
|
||||
- Stations and office reach the application only through the gateway's
|
||||
Caddy, with the wildcard certificate the fleet already issues; the
|
||||
servers VLAN accepts nothing from other VLANs.
|
||||
- Staff sign-on through an OIDC provider on `vinyl-core` (Pocket ID,
|
||||
passkeys; the fleet has no identity provider yet, so this is the first)
|
||||
with roles: admin, engineer, operator, sales, customer. Stations
|
||||
authenticate by badge for attribution, not for privilege.
|
||||
- Secrets only in clan vars (YubiKey-gated, `admins` group); nothing in
|
||||
plain text in either repo.
|
||||
- Client audio: separate encrypted ZFS dataset, SFTP or portal upload with
|
||||
checksums, every read logged, a written policy sales can show a label.
|
||||
- UPS on `core-1`, `router-1`, the switches, the edge collectors and the
|
||||
press PLCs (already required by facility security); NUT triggers a clean
|
||||
shutdown before the battery is exhausted.
|
||||
- Signed commits on the clan repo; deployments only from a reviewed branch.
|
||||
- UPS on `vinyl-core`, `gw-lpn-1`, the switches, the edge collectors and
|
||||
the press PLCs (already required by facility security); NUT triggers a
|
||||
clean shutdown before the battery is exhausted.
|
||||
- Admin access rides the mesh, as for every fleet machine; public SSH is
|
||||
never opened.
|
||||
|
||||
## Procurement clauses
|
||||
|
||||
@@ -481,7 +608,7 @@ To go into every RFQ that leaves from [roadmap](roadmap.md) items 4 to 8:
|
||||
1. **Presses (Newbilt, Pheenix)**: OPC UA (or S7/ADS) read access licensed
|
||||
and enabled; the full tag list with units and the cycle counter as a
|
||||
tag; a defined hand-off of the cycle counter to the inspection trigger;
|
||||
remote support through our jump host; no cloud agent as a warranty
|
||||
remote support through our mesh; no cloud agent as a warranty
|
||||
condition; PLC clock accepting NTP.
|
||||
2. **Boiler, chiller, compressor, heat pump (Thai vendors)**: Modbus RTU or
|
||||
TCP with the register map delivered; alarm contacts wired to a terminal
|
||||
@@ -491,13 +618,16 @@ To go into every RFQ that leaves from [roadmap](roadmap.md) items 4 to 8:
|
||||
loops terminated in the edge cabinets.
|
||||
4. **Electrical contractor**: Modbus energy meters on the feeders listed
|
||||
above; RS485 to the inverters and BESS BMS without cloud dongles;
|
||||
structured cabling and a VLAN-capable switch in every cabinet.
|
||||
structured cabling, a VLAN-capable industrial switch in every cabinet,
|
||||
and Omada-managed switches and APs for the building so the gateway's
|
||||
existing Omada controller covers the site.
|
||||
5. **Galvanics (Digital Matrix)**: what the rectifiers and control rings
|
||||
expose, and how; Modbus preferred.
|
||||
6. **Metrology (Keyence Thailand)**: confirmed CSV/3D export paths and
|
||||
whether the instrument software can write to a network share unattended.
|
||||
7. **Vision integrator**: result string format, image push, cycle counter
|
||||
correlation, and an acceptance test defined in records not in features.
|
||||
7. **Vision integrator**: result string format, image push over SFTP,
|
||||
cycle counter correlation, and an acceptance test defined in records not
|
||||
in features.
|
||||
8. **Access control and fire**: API or export for door events; dry
|
||||
contacts for every alarm class; BESS detection outputs.
|
||||
|
||||
@@ -509,23 +639,26 @@ Aligned with the [roadmap](roadmap.md) phases.
|
||||
|
||||
- Put the procurement clauses above into the Newbilt re-quote, the
|
||||
Pheenix, Digital Matrix and Thai utility RFQs.
|
||||
- Create the clan repo and a development clan of three small machines at
|
||||
the office: a `core-1` stand-in, one edge collector with a Modbus and
|
||||
OPC UA simulator, one station. This proves the tooling before a single
|
||||
plant machine exists.
|
||||
- Build the factory application v0 against a press simulator (the state
|
||||
machine in the plant operation page is the seed: same states, same
|
||||
cycle timing) so orders, gates, genealogy and press cycles can be
|
||||
exercised end to end without hardware.
|
||||
- Decide the repository layout: this repository stays documents; the clan
|
||||
flake and the application get their own repositories in the same Gitea
|
||||
organisation, linked from here (see open questions).
|
||||
- In the clan repo: reserve the site id and VLAN table, write
|
||||
`modules/vinyl/{core,metrics,edge,station}.nix`, and stand up a dev
|
||||
trio at the Chiang Mai site behind `gw-cnx-1` (a `vinyl-core` stand-in,
|
||||
one edge collector with a Modbus and OPC UA simulator, one station).
|
||||
This proves the modules, the mesh path and the proxy before a single
|
||||
plant machine exists, and the machines move to the plant when it does.
|
||||
- Land the three router-module extensions on `gw-cnx-1` first, where they
|
||||
are also useful.
|
||||
- Start `cnx-factory` v0 against a press simulator (the state machine in
|
||||
the plant operation page is the seed: same states, same cycle timing) so
|
||||
orders, gates, genealogy and press cycles can be exercised end to end
|
||||
without hardware; package it as a flake from the first commit.
|
||||
- Wire the Alertmanager and one real receiver; point `control`'s vmalert
|
||||
at it.
|
||||
|
||||
**Build and commission (roadmap Phase 3).**
|
||||
|
||||
- Network, `router-1`, `core-1`, `backup-1` and `vps-1` installed before
|
||||
- `gw-lpn-1`, switches, `vinyl-core` and `vinyl-backup` installed before
|
||||
the machinery arrives, so vendor commissioning engineers plug into a
|
||||
finished network.
|
||||
finished network; ns1 gets the gateway's ACME key at the same time.
|
||||
- Zone sensor loops, meters and edge cabinets installed by the electrical
|
||||
and HVAC contractors during fit-out; environment logging is live before
|
||||
pressing starts, which gives a baseline.
|
||||
@@ -535,18 +668,19 @@ Aligned with the [roadmap](roadmap.md) phases.
|
||||
- Application v1 live: intake, gates, bridge-stamper genealogy, press runs
|
||||
and cycles, PVC lot gate, packaging scan, shipments; stations at press,
|
||||
lab, packaging and shipping.
|
||||
- Off-site backup destination live and a first restore drill done.
|
||||
|
||||
**Launch (roadmap Phase 4).**
|
||||
|
||||
- Optical inspection integrated and correlated; reject reasons flowing.
|
||||
- Customer portal opened to the first labels.
|
||||
- Customer portal opened to the first labels through `web01`.
|
||||
- Energy and environment dashboards used for the first PV and HVAC
|
||||
tuning.
|
||||
|
||||
**Expand (roadmap Phase 5).**
|
||||
|
||||
- `edge-galvanics`, bath sensors, rectifier data, metrology ingestion at
|
||||
`st-metrology`; genealogy switches from bridged to in-house.
|
||||
- `vinyl-edge-galv`, bath sensors, rectifier data, metrology ingestion at
|
||||
`vinyl-st-metrology`; genealogy switches from bridged to in-house.
|
||||
- Audio QC station and pipeline; retirement signal live.
|
||||
- Automated press line joins the same collector with the same tag family.
|
||||
- Biomass boiler on the same Modbus path as its predecessor.
|
||||
@@ -555,21 +689,23 @@ Aligned with the [roadmap](roadmap.md) phases.
|
||||
|
||||
Planning estimates, September 2026, excluding the QC instruments (those
|
||||
are in quality automation) and excluding the vendors' OPC UA license
|
||||
options, which come back with the quotes.
|
||||
options, which come back with the quotes. Fleet pieces already paid for
|
||||
(`control`, `ns1`, `ns2`, `web01`, the mesh) cost the plant nothing extra.
|
||||
|
||||
| Block | Estimate (USD) |
|
||||
|---|---|
|
||||
| `core-1` and `backup-1` servers, UPS, rack | 8,000 to 15,000 |
|
||||
| `router-1`, managed switches (industrial in the cabinets), cabling allowance | 4,000 to 8,000 |
|
||||
| `gw-lpn-1` (Topton 1U, fleet standard) | 300 to 500 |
|
||||
| `vinyl-core` and `vinyl-backup` servers, UPS, rack | 8,000 to 15,000 |
|
||||
| Omada switches and APs for the building, industrial switches in the cabinets, cabling allowance | 4,000 to 8,000 |
|
||||
| 3 edge collectors with I/O modules and enclosures | 3,000 to 6,000 |
|
||||
| 8 station kiosks with readers, scanners, one barcode verifier, one darkfield camera | 8,000 to 15,000 |
|
||||
| zone environment sensors (12 to 16 points), room dP, reference PM instrument | 4,000 to 8,000 |
|
||||
| energy meters (10 feeders), water meters, level transmitters | 3,000 to 6,000 |
|
||||
| audio QC hardware (turntable, arm, cartridge, phono stage, interface) | 2,000 to 5,000 |
|
||||
| `vps-1` and off-site storage, per year | 500 to 1,500 |
|
||||
| off-site backup storage, per year | 100 to 500 |
|
||||
| **Hardware total** | **~32,000 to 64,000** |
|
||||
| Application development to v1 (orders through shipments, stations, portal) | 4 to 6 person-months |
|
||||
| Clan fleet, modules and collectors to commissioning | 1 to 2 person-months |
|
||||
| `cnx-factory` to v1 (orders through shipments, stations, portal) | 4 to 6 person-months |
|
||||
| Clan modules, router extensions, collectors, dashboards and rules to commissioning | 1 to 2 person-months |
|
||||
| Vision, metrology and audio pipeline integration (Launch and Expand) | 3 to 5 person-months, plus integrator fees in the vision quote |
|
||||
|
||||
Headcount note: [scale](scale.md) lists no IT or automation role in the
|
||||
@@ -578,22 +714,22 @@ Build onward, part-time at launch; add it to the headcount.
|
||||
|
||||
## Open questions
|
||||
|
||||
- Site code and id: `lpn` / 3 assumed; confirm when the site is chosen and
|
||||
the fleet site table is updated.
|
||||
- Semi-automatic press PLC: does the HRP 12 expose data, or is the sensor
|
||||
fallback needed? (Ask in the Newbilt re-quote.)
|
||||
- Cycle counter hand-off to the vision system: PLC output, network
|
||||
message, or time correlation at the unloader? Decided with the vision
|
||||
integrator, tested at acceptance.
|
||||
- HVAC BMS protocol and who owns the zone sensors: HVAC contractor or us.
|
||||
- Where `vps-1` lives: outside Thailand (latency to the mesh, data
|
||||
residency for customer data) or a Bangkok provider.
|
||||
- Portal availability: served through the mesh from `core-1` (down when
|
||||
the plant's internet is down) or a read replica on `vps-1` (more moving
|
||||
parts). Start with the former.
|
||||
- Off-site backup destination: Hetzner Storage Box (cheapest) or a storage
|
||||
VPS that is also a mesh peer (uniform tooling). Data residency for
|
||||
customer audio may argue for a Bangkok provider instead.
|
||||
- Customer portal domain: the plant's brand domain (new zone on ns1/ns2,
|
||||
second cert on `web01`) or a name under `cnx.network` for launch.
|
||||
- Portal availability during a plant WAN outage: accept it (the portal is
|
||||
a view of live data) or add a read replica on the fleet side later.
|
||||
- Accounting and ERP: out of scope for the application; if an ERP is
|
||||
adopted later it references the same order IDs. Decide after launch.
|
||||
- Repository layout: documents here, `cnx-infra` (clan) and `cnx-factory`
|
||||
(application) as separate repositories, or everything in one. The
|
||||
README currently promises this repository will hold the software; a
|
||||
link satisfies that.
|
||||
- Dead-wax code readability on black and coloured vinyl with a camera:
|
||||
test with samples before the packaging station is designed.
|
||||