Feedwater heat recovery: economizer, condensate, then HP-1
Deploy test site / deploy (push) Successful in 48s

The order to investigate for a fired boiler (biomass such as rice
husk, or LPG): first a flue-gas economizer, second as much clean, hot
condensate back to T-1 as possible, third the heat pump HP-1 where the
press return has enough heat and the combined heating and cooling
economics justify it.

- Diagram: new ECON-1 (option, fired boilers only) between the feed
  pumps and the boiler manifold, with a bypass for an electric bank and
  the flue-gas path from the boilers; feed in 90 to 95 C, outlet and
  stack temperature are vendor figures. HP-1 is now drawn as an option
  and labelled the third measure. AT conductivity on the condensate
  return to T-1; off-spec condensate goes to the warm tank.
- Found in Newbilt's offer 240620-04: steam and cooling water share the
  mould channels, with one steam/water outlet valve and steam trap per
  mould, so the condensate is only as clean as the cooling loop. Noted
  in the T-1 detail, sustainability.md and as a Newbilt RFQ question.
- With most condensate returned (about 15 % flashes at atmospheric
  pressure, estimate) the feed tank needs only a fraction of the ~70 kW
  that heating all make-up takes, so HP-1 may not pay.
- RFQ: economizer outlet feed and stack temperature, corrosion limit,
  pressure drop; rice husk ash is high in silica and abrasive, so
  fouling, cleaning, wear protection and a bypass.
- sustainability.md: the order, before the exclusions. biomass.md: new
  "Recovering heat at the boiler".

Checked headless (scripts/pw_sc_check.py): 33 boxes, 20 tags, no
overlap or overflow, no unstyled pipes, no card or page overflow at
1600, 1258 and 390 px in all four cases, every box opens its detail, no
errors.
This commit is contained in:
grabowski committed 2026-10-14 11:03:34 +07:00
1 parent b1c18cb040
commit cb5809e73c
3 files changed
+45 -12

No files matched your search

+12
View File
@@ -27,6 +27,18 @@ load and realistic duty cycles:
is what the fuel store and the monsoon
stock have to be sized for (estimate)
### Recovering heat at the boiler
A fired boiler loses heat up its stack, so an economizer that preheats the
boiler feedwater with the flue gas is the first heat-recovery measure to
investigate, ahead of condensate return and the feedwater heat pump
([sustainability](sustainability.md#energy-efficiency-architecture-recover-before-generating)).
How far the flue gas can be cooled is the vendor's figure: it depends on
the flue-gas temperature, the corrosion limit and the fuel. Rice husk ash
is high in silica and abrasive, so the RFQ asks for fouling and cleaning
provisions, wear protection and a bypass rather than a clean-gas
economizer ([steam and cooling](steam-cooling.html)).