Commit Graph
9 Commits
Author SHA1 Message Date
janikandClaude Fable 5 7f8672d7b9 GUI: live STM32 telemetry + sweep guards + auto-logging + bench-plot
- stm32_link.py: port to the live 114-byte broadcast protocol (magic
  0xAA55AA55, odd parity 8-O-1, 100 Hz publish, repetition-validated,
  no CRC); 39 params incl. adc4_trig_phase/iin_zero_sum, CLEAR_FLAGS,
  30-bit flag table; commands stay CRC-16 framed; Telemetry aliases
  BroadcastData, efficiency uses iout_slow and eff_net subtracts P_sys
- gui_workers.py: STM32Worker reader thread with counter dedup, rate/
  loss counters, 20 s graph history, full-rate telemetry CSV writer
- gui.py: right-side telemetry panel (link state, power + EFF net,
  heatsink/board temps, Vfly group, control, HRTIM, status-flag
  checkboxes, fault registers), Vfly + selectable corr/phase-ofs
  graphs, 20 s rolling window on all plots, dual CSV logging (merged
  stm_* columns + <stem>_telem.csv), logging on by default into
  logs/data_<timestamp>.csv, Plot Eff button
- sweep guards: PSU 20 A input-current gate (conservative estimate +
  measured backstop + I-limit clamp), thermal pause at 57/77 C holding
  the load at 1 A until cooled 5 C below threshold, CC range pinned to
  R2 for the whole run with empirical range-max readback rejection
- plot_eff.py + bench-plot entry point: efficiency vs Vin vs current
  maps from any logged CSV (sweep / data log / telem autodetect), file
  dialog when launched without args
- bench.py: HIOKI FAST response speed, 5 s settle defaults; cli.py
  stm32-read prints the full broadcast; README + .gitignore updates

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 18:06:02 +07:00
janikandClaude Opus 4.8 d2dfc73f9e tooling: sync bench + debug console to live STM32 protocol
The mppt-testbench Python tooling had drifted from the flashed firmware
(bundled fw e7a23a3 vs live 1b85532) and could no longer communicate:

- stm32_link.py: CRC8 -> CRC-16/CCITT-FALSE; telemetry 68B -> 78B
  (btemp, cmp_outer/inner, iout_slow, vfly_ofs_applied); add PTYPE_INT16
  and commands 0x12-0x18; replace PARAMS with the current 37-param map
  (single dt_normal, no dt brackets; test_corr/phase_ofs, phase PI,
  precharge PI, duty dither; vfly_active 0-3).
- tuner.py: retire per-bracket deadtime; sweep the single dt_normal.
- cli.py: update tune-deadtime, help/examples, btemp readout;
  default ports COM11 (load) / COM4 (stm32).
- debug console TUI: sync protocol.py/app.py/status_bar/telemetry_panel
  from live (new command keys, link RX/TX/loss stats, single dead-time,
  new telemetry fields, param-write auto-retry); add duty_fft.py.
- README: rewrite parameter table, deadtime section, ports, keybindings.

Verified: protocol round-trip self-tests + live `bench stm32-read`
reading all 37 params over COM4.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-01 12:03:51 +07:00
grabowskiandClaude Opus 4.6 903fa78585 Add tune-param-vsweep command for parameter sweeps across voltage range
Automates running tune-param at multiple voltages, saves per-voltage
CSVs compatible with plot-tune, and prints a summary table.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-13 15:51:59 +07:00
grabowskiandClaude Opus 4.6 ce493204cb Add plot-tune command for multi-voltage parameter sweep analysis
Overlays efficiency curves from multiple CSV files (one per voltage),
finds per-voltage best and overall sweetspot (best average across all
voltages), and generates efficiency overlay, heatmap, and loss plots.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-13 11:40:42 +07:00
grabowskiandClaude Opus 4.6 1c41910c1e Add STM32 tuning integration and rewrite README with step-by-step guide
- stm32_link.py: synchronous serial interface to STM32 debug protocol
  (ping, telemetry read/avg, param read/write, frame parser)
- tuner.py: automated tuning combining HIOKI + STM32 measurements
  (param sweep, deadtime optimization, multi-point sweep, CSV/plot output)
- CLI commands: stm32-read, stm32-write, tune-param, tune-deadtime
- README: complete step-by-step guide covering setup, sweeps, analysis,
  tuning, shade profiles, debug console, and parameter reference

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-12 16:52:09 +07:00
grabowskiandClaude Opus 4.6 3f65b5f2f2 Add plot-sweep command, degauss buttons, sweep ramp-down, and time estimate
- Add offline `plot-sweep` CLI command: generates efficiency overlay,
  heatmap, and power loss plots from sweep CSV (no instruments needed)
- Add degauss buttons to CH5/CH6 in GUI (sends :DEMAg SCPI command)
- Gradual load ramp-down at end of 2D sweep to avoid transients
- Live sweep time estimate in GUI based on grid size × settle time
- Update HIOKI submodule to include degauss CLI command

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-12 16:31:33 +07:00
grabowskiandClaude Opus 4.6 aced4f1e23 Add CP load mode to 2D sweep and supply sanity checks
- 2D sweep now supports CC (constant current) and CP (constant power)
  load modes via --load-mode flag (CLI) and combobox (GUI)
- Supply capability check before all sweeps: validates max voltage
  against supply range and prints V/I/P summary
- Renamed sweep-vi args from --i-start/stop/step to --l-start/stop/step
  to reflect that the load setpoint can be current or power
- GUI labels update dynamically based on selected load mode

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-11 15:57:44 +07:00
grabowskiandClaude Opus 4.6 956be4b77a Add shade profiles, 2D V×I sweep, meter format toggle, ON/OFF indicators, and GUI console
- Shade profile: CSV-driven irradiance/voltage sequences with load control
  (bench.run_shade_profile, CLI shade-profile command, GUI profile panel)
- 2D sweep: voltage × load current efficiency map with live graph updates
  (bench.sweep_vi, CLI sweep-vi command, GUI sweep panel with background thread)
- GUI: meter format selector (scientific/normal), supply/load ON/OFF indicators,
  console log with stdout redirect and color-coded messages
- Sample profiles: cloud_pass, partial_shade, intermittent_clouds

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-11 15:27:48 +07:00
grabowskiandClaude Opus 4.6 e55caa59b1 Initial MPPT testbench: unified CLI for IT6500D + Prodigit 3366G + HIOKI 3193-10
Combines three instrument drivers (as git submodules) into a single
testbench for MPPT tracker efficiency testing. Features:
- Voltage sweep and load current sweep with CSV export
- Auto-range aware meter polling (waits for HIOKI to settle)
- Supply keepalive during long meter waits to prevent USB-TMC timeouts
- Live monitoring with real-time 4-panel matplotlib graphs
- Safe shutdown (load first, then supply)
- Post-sweep returns to 75V idle with supply ON

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>