Files
kicad-zone-resistance/tests
janik b2277f65bf
Build PCM package / build (push) Successful in 8s
Full solder joint at every populated THT pad, read from KiCad
No size-threshold guessing: whether a hole is a via or a THT pad
already comes from KiCad (board.get_vias vs drilled board.get_pads).
Every populated THT pad of the net now carries the complete joint the
contacts got: solder-filled barrel, average-thickness coat over a
pad-diameter disc on the outer layers, and the protruding-lead cone on
the side opposite its owning footprint. The footprint side and the
Do-not-populate flag are read from KiCad (footprint pads store absolute
positions, so owner lookup is an exact (x, y, number) map); DNP pads
stay plating-only with no joint. Contact pads are deduplicated by
barrel center so their cone/coat is never applied twice.

Barrels are now gathered in single-layer runs too: via rings and drill
mouths perforate a lone plane, THT joints stiffen it locally.

ViaLink gains solder_filled + protrusion_side (legacy dumps load with
the old every-THT-pad-filled semantics).

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-16 19:00:09 +07:00
..