Real boards vs. a UT3513+ micro-ohm meter, agreement within +/-20%, attributed to test-setup imperfections and manufacturing tolerances. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -232,6 +232,15 @@ SWIG API. Requires KiCad **10.0.1+**.
|
|||||||
in plane interiors), the tin-gray solder coat of the THT-pad contact
|
in plane interiors), the tin-gray solder coat of the THT-pad contact
|
||||||
P1, and the via field with its pad copper.*
|
P1, and the via field with its pad copper.*
|
||||||
|
|
||||||
|
**Measured vs. computed**: we tested the plugin on a few real boards
|
||||||
|
against a UT3513+ micro-ohm meter; the measured resistances were within
|
||||||
|
±20 % of the computed values. We attribute the deviation to
|
||||||
|
imperfections of the testing setup (probe placement and probe contact
|
||||||
|
resistance vs. the ideal modeled contacts) and to manufacturing
|
||||||
|
inaccuracies — actual copper and plating thicknesses routinely deviate
|
||||||
|
from nominal. Relative comparisons between layout variants are
|
||||||
|
accordingly more trustworthy than absolute numbers.
|
||||||
|
|
||||||