README: measured-vs-computed validation paragraph
Build PCM package / build (push) Successful in 7s

Real boards vs. a UT3513+ micro-ohm meter, agreement within +/-20%,
attributed to test-setup imperfections and manufacturing tolerances.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
janik
2026-07-17 13:01:28 +07:00
parent 3bf15b44a9
commit 8bc3c50872
+9
View File
@@ -232,6 +232,15 @@ SWIG API. Requires KiCad **10.0.1+**.
in plane interiors), the tin-gray solder coat of the THT-pad contact
P1, and the via field with its pad copper.*
**Measured vs. computed**: we tested the plugin on a few real boards
against a UT3513+ micro-ohm meter; the measured resistances were within
±20 % of the computed values. We attribute the deviation to
imperfections of the testing setup (probe placement and probe contact
resistance vs. the ideal modeled contacts) and to manufacturing
inaccuracies — actual copper and plating thicknesses routinely deviate
from nominal. Relative comparisons between layout variants are
accordingly more trustworthy than absolute numbers.
## Offline / development
Every run writes `geometry_dump.json`; re-solve without KiCad: