Fleet: one shared hydraulic and air supply; room for ten more Classics
User, October 2026: the presses run from one shared hydraulic supply and one compressed-air supply, and the plant may add up to ten more Newbilt Classics at some point. - pressing-line: fleet table and intro (shared central supply), new bullets on the shared supply and the expansion option, re-quote point (central supply for the whole fleet, extendable, can the Classic run from it), Hydraulics bullet now the plan. - scale: "Expansion (option)" capacity row, ~4.7 to 5.8M records/yr on the same basis, explicitly outside revenue model and investment; utilities note: fifteen presses would need ~2.3 to 2.7 t/h steam and up to ~1.9 MW cooling, a utility phase of its own.
This commit is contained in:
1 parent
f2bb7f3d85
commit
9e0c5d4045
2 files changed
+45
-16
No files matched your search
+10
-2
@@ -12,6 +12,7 @@ page as real quotes and the site decision land.
|
||||
| Launch | 1 semi-auto press (Newbilt Single, the first half of Duplex system 1), 1 shift | ~90,000 to 135,000 records/yr |
|
||||
| Duplex | 2 semi-auto presses (Duplex system 1: EX 50 main and EX 35 colour extruder), 1 to 2 shifts | ~175,000 to 540,000 records/yr |
|
||||
| Mature | 4 semi-auto (two Duplex systems, each EX 50 + EX 35) + 1 automated (Newbilt Classic), 2 shifts | ~1.0 to 1.5 million records/yr |
|
||||
| Expansion (option) | the mature fleet + up to 10 more Newbilt Classics, 2 shifts | ~4.7 to 5.8 million records/yr (estimate) |
|
||||
|
||||
Basis: the current fleet plan of October 2026
|
||||
([pressing line](equipment/pressing-line.md)). The automated Classic
|
||||
@@ -22,7 +23,10 @@ effectiveness of 60 to 70% applied: 368 to 448 records/hour, ~1.06 to 1.5
|
||||
million a year. The theoretical ceiling of the mature fleet at 100% uptime
|
||||
is roughly 1.8 to 2.2 million records per year. (The earlier 50/50 fleet,
|
||||
two semi-automatic presses and two Pheenix AD12s, landed in the same
|
||||
range.)
|
||||
range.) The expansion row is an option the plant keeps room for, not a
|
||||
plan: ten more Classics add ~1,280 records/hour on the same basis, and
|
||||
neither the [revenue model](finance/revenue-model.md) nor the investment
|
||||
includes them.
|
||||
|
||||
**The 60–70% effectiveness assumption is worth challenging, but not yet
|
||||
changing.** Newbilt publishes ≥95% yield and ≥95% uptime for the Classic
|
||||
@@ -178,7 +182,11 @@ and peak rows above are sized for one Duplex's ~250 kW of cooling; at
|
||||
Newbilt's up to 125 kW of cooling per press, five presses need up to ~625
|
||||
kW, so the chiller's electrical draw and the plant peak rise accordingly.
|
||||
Re-size with the Newbilt re-quote figures, together with the steam below
|
||||
([pressing line](equipment/pressing-line.md)).
|
||||
([pressing line](equipment/pressing-line.md)). The presses share one
|
||||
central hydraulic plant and one compressed-air plant; their draw replaces
|
||||
the per-system hydraulic units in the pressing row above. The optional
|
||||
ten more Classics would need up to ~1.9 MW of cooling and ~2.3 to 2.7 t/h
|
||||
of steam: a utility phase of its own.
|
||||
|
||||
Tariff: PEA Schedule 3.2.2, Medium General Service on time of use at
|
||||
22 kV (the flat rate is closed to new customers): 132.93 THB/kW demand
|
||||
|
||||