Duplex cell layout: one operator, presses turned towards him
User sketch, October 2026 (filed as docs/equipment/ duplex-cell-layout-sketch.png; arrangement only, the user notes it is not to scale): operator in the middle, the two presses either side turned 45 degrees towards him, EX 50 and EX 35 side by side behind him, one trimmer per cell in front on the left. Sized from the Newbilt site requirements p. 10 (press ~0.9 m2, extruder ~0.5 m2, hydraulic aggregate ~1.0 m2, walk-around space, >= 60 cm to walls, room height >= 2.5 m): cell ~5 x 3 m, 0.6 to 0.8 m between machines; EX 35 and trimmer footprints are estimates. The layout drawing the site requirements refer to on p. 11 is missing from our copy: ask for it with the re-quote. README layout line for the sketch.