Reusable cnx.router.* module for the Topton 1U boxes replacing OPNsense:
PPPoE WAN (optionally VLAN-tagged, AIS: 10, secret credentials incl.
username), VLAN-filtering bridge, nftables NAT/firewall with MSS clamp,
Kea DHCP with per-VLAN lease time, Blocky DNS, DHCPv6-PD, CrowdSec with
the ZeroTier mesh whitelisted, optional Omada controller, ZFS disk.
Fleet baseline rides along: admins sops group is now derived for every
machine in clan.nix (secrets encrypt to it from the first vars generate)
and time sync is chrony everywhere instead of systemd-timesyncd.
Grafana 13 externalised its core data sources; nixpkgs no longer bundles
the Elasticsearch datasource, so every DMARC panel failed with "Plugin not
registered". Load the official Grafana-signed elasticsearch plugin via
declarativePlugins, pin the dmarc-ag/dmarc-fo datasource UIDs (Grafana 11+
resolves datasource template variables by UID, not name), and clear stale
uid-less records left by an earlier deploy.
Bump clan-core and nixos-mailserver to 26.05 (NixOS 26.05) and adapt to
the breaking changes surfaced by nix flake check:
- mesh-hosts/clan.nix: read the new shared, instance-scoped zerotier vars
(zerotier-ip-<machine>-zerotier, zerotier-network-zerotier); admit
external members via the controller's native allowedIds.
- monitoring/server.nix: Grafana lost its built-in secret_key default;
mint one via a clan generator and pass it with $__file{}.
- dns/authoritative.nix: services.resolved.extraConfig removed -> settings.
- mail.nix: SNM cert API change (x509.useACMEHost + acme extraDomainNames)
and accounts/dkim option renames.
- docs: mesh runbook updated for the new var paths and allowedIds.
Deliver cnx.email DMARC aggregate/forensic reports to a dedicated dmarc@cnx.email
mailbox on mx1 and analyze them with parsedmarc on control, storing parsed
reports in a local loopback Elasticsearch and visualizing via the auto-provisioned
Grafana dashboard. parsedmarc fetches the mailbox over IMAPS across the mesh
(mx1.cnx.email pinned to its mesh address so TLS still validates), using a shared
mail-dmarc-cred clan var so mx1's mailserver and control see the same password.
Pure formatting (nixfmt/prettier/yamlfmt); no behavior change. These
files predate the current treefmt config and were failing nix flake
check; reformatting them makes the gate green again.
- Register mx1 in the inventory and as a direct-SSH `internet` host; give it
a static public IPv6 (2a01:4ff:2f0:1963::1).
- Point the cnx.email MX (plus SPF/DMARC) at mx1 and add its A record.
- Bring mx1 into monitoring: import exporters, add it to the mesh map and the
node scrape job so its host metrics and journald reach control.
- Add a clan-mx1 Hetzner firewall: inbound SMTP + ZeroTier + ICMP, no public
SSH (admin rides the mesh like the other hosts). 587/465/993 held for now.
- Extract per-host public IPv4/IPv6 into modules/hosts.nix, consumed by
clan.nix's internet hosts and each machine's cnx.staticIPv6, so each address
is declared once instead of being duplicated across configs.
- docs: add mx1 to the machines table.
VictoriaLogs, like the VM scraper, is IPv4-only by default: ":9428" binds
0.0.0.0 only, so ns1/ns2 pushing journald over the IPv6 mesh got "connection
refused" while control's own loopback (v4) upload worked. Add -enableTCP6 so it
binds [::] (dual-stack), matching the flag already used for the scraper.
Also simplify the systemd-journal-upload override to just startLimitIntervalSec=0
(retry forever / self-heal) and drop the SuccessExitStatus masking: a persistent
sink failure should stay loud rather than be hidden behind a green deploy.
The uploader exits when VictoriaLogs is unreachable. Upstream already sets
Restart=always/RestartSec=3sec, but the default start-rate limit lets the unit
give up permanently and trip switch-to-configuration when the sink is briefly
down. Disable the limit (startLimitIntervalSec=0) so logging stays best-effort
and never wedges a host or a deploy.
control runs VictoriaLogs (:9428, 30d, mesh-scoped) with a matching
Grafana datasource. Each host ships journald via systemd's own
journald.upload to the /insert/journald endpoint -- no extra agent.
control uploads over loopback so its logs survive a mesh outage; ns1
and ns2 push over the mesh.
DNSResolutionProbeFailed and DNSSECProbeFailed fire when an SOA or
DNSKEY probe to a public nameserver address stays down for 5m. The CNX
DNS dashboard gains a "DNS probes (outside-in)" row: per-zone/server
status table, probe success, and probe latency.
control runs blackbox_exporter on loopback, probing each nameserver's
public v4+v6 address for every zone: SOA (zone served) and DNSKEY (still
signed, since blackbox has no DO-bit option). Probe definitions are
shared between the exporter config and the VictoriaMetrics scrape jobs
so they can't drift. Verified live against ns1/ns2 over v4 and v6.
BackupJobFailed fires when a borgbackup job enters the systemd failed
state; BackupStale fires when the daily timer has not run in over 26h
(or has never run). Both read the node_exporter systemd collector on
the backup client, matching the CNX Backups dashboard.
Grafana dashboard (auto-provisioned from the dashboards dir) tracks
borgbackup job health, time since last run, and per-job systemd state
from the node_exporter systemd collector on the client. New docs page
covers the ns1 -> control topology, secrets flow, and restore commands.
Surfaces vmalert's firing ALERTS series as a table at the top of the dashboard,
so the minimal-delivery alerts are visible at a glance. Existing panels shift
down by one row.
vmalert on control evaluates rules (declared in git) against VictoriaMetrics and
remote-writes alert state back, so firing alerts show as the ALERTS series in
Grafana. Covers SOA divergence between ns1/ns2, secondary zone expiry, scrape
target down, and root disk full. No notifier yet (notifier.blackhole). Also adds
TODO.md roadmap.
The control/ns1/ns2 mesh IPs and the /88 subnet were duplicated literals in
mesh-hosts.nix. clan-core's zerotier generator already writes each machine's IP
as a public var (vars/per-machine/<m>/zerotier/zerotier-ip), so read from there
and derive the subnet from zerotier-network-id. Pure refactor: the rendered
values are identical and the system derivation hash is unchanged.
control runs VictoriaMetrics (loopback) and Grafana; every machine exports
node metrics and the nameservers export Knot stats (mod-stats + knot-exporter).
Scraping and the Grafana UI ride the ZeroTier mesh only, scoped by nftables to
the mesh /88; the public side stays closed by the Hetzner cloud firewall. The
provisioned DNS dashboard includes a per-zone SOA serial table to catch
primary/secondary drift. ZeroTier ULAs are centralised in mesh-hosts.nix.