Add untagged access ports and a staging uplink for gw-cnx-1
New cnx.router.accessPorts option pins a port untagged to one VLAN via bridge PVID/EgressUntagged; convention is the last copper port as an always-available mgmt recovery port. gw-cnx-1 port roles: enp1s0 WAN, enp2s0 trunk, enp3s0 temporary DHCP uplink into the old OPNsense LAN (back to trunk at cutover), enp4s0 untagged mgmt.
This commit is contained in:
@@ -28,9 +28,11 @@
|
||||
wan.vlanId = null; # this ISP runs PPPoE untagged on the port
|
||||
trunkPorts = [
|
||||
"enp2s0"
|
||||
"enp3s0"
|
||||
"enp4s0"
|
||||
# "enp3s0" # STAGING: serves as the uplink below until cutover
|
||||
];
|
||||
# Dedicated on-site recovery port: untagged mgmt, always available even
|
||||
# if the switch config is broken.
|
||||
accessPorts.enp4s0 = "mgmt";
|
||||
# Replaces the newedge.house OPNsense box; renumbered to the fleet
|
||||
# convention (10.1.<vlanId>.0/24, router .1, pool .100-.199). The old
|
||||
# untagged LAN becomes tagged mgmt — infra switch ports get PVID 10.
|
||||
@@ -73,6 +75,17 @@
|
||||
};
|
||||
};
|
||||
|
||||
# STAGING (remove at cutover, and restore enp3s0 to trunkPorts): DHCP-client
|
||||
# uplink into the existing OPNsense LAN so the box has internet + mesh while
|
||||
# it runs alongside the old router. Default-deny firewall on this interface
|
||||
# (it's in no VLAN zone); PPPoE simply retries until the WAN port is cabled.
|
||||
# Do NOT connect the trunk ports to the production switch while staging —
|
||||
# Kea on tag 10 would fight the OPNsense LAN DHCP in one broadcast domain.
|
||||
systemd.network.networks."05-staging" = {
|
||||
matchConfig.Name = "enp3s0";
|
||||
networkConfig.DHCP = "ipv4";
|
||||
};
|
||||
|
||||
time.timeZone = "Etc/GMT-7"; # UTC+7 (Thailand, fixed offset, no DST)
|
||||
services.chrony.enable = true;
|
||||
}
|
||||
|
||||
Reference in New Issue