Renumber gw-cnx-1 to the fleet addressing scheme (OPNsense replacement)
The newedge.house site adopts the 10.1.<vlanId>.0/24 convention: mgmt 10 (the old untagged LAN), lan 20, iot 40, voip 50, dmz 60, unit1-5 110-150. PPPoE is untagged at this site. Static leases move to a new per-VLAN dhcp.reservations option rendered into Kea host reservations.
This commit is contained in:
@@ -42,9 +42,13 @@ should also shorten `dhcp.leaseTime` (default 86400 s) so the pool recycles.
|
||||
First user: `gw-cnx-2` (site 2) runs the public WiFi — guest VLAN 30 at
|
||||
`10.2.128.0/22`, pool `10.2.128.100 – 10.2.131.250`, `dhcp.leaseTime = 3600`.
|
||||
|
||||
| Site | siteId | mgmt | lan |
|
||||
| ---- | ------ | -------------- | -------------- |
|
||||
| cnx | 1 | `10.1.10.0/24` | `10.1.20.0/24` |
|
||||
| Site | siteId | mgmt | lan | site-specific VLANs |
|
||||
| ---- | ------ | -------------- | -------------- | --------------------------------------------------------------- |
|
||||
| cnx | 1 | `10.1.10.0/24` | `10.1.20.0/24` | iot 40, voip 50, dmz 60, unit1–5 110/120/130/140/150 (all /24s) |
|
||||
|
||||
Static DHCP leases are declared per VLAN via `dhcp.reservations` (attribute
|
||||
name = hostname, plus `hwAddress`/`ipAddress`); park them outside the pool,
|
||||
in the `.2–.99` infra range or `.200–.254`.
|
||||
|
||||
Trust model: mgmt → everything; other VLANs → router DNS/DHCP + internet only
|
||||
(no inter-VLAN); WAN → nothing inbound; mesh → SSH, metrics, Omada UI.
|
||||
|
||||
Reference in New Issue